For Integral Blower Installations: • Requires Integral Blower: Model # VTN600CVA • Requires Round Duct Size (6" Diam.) • Requires Dedicated Branch Cir cuit P ow er Supply • 120 V olt A C• min.
SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS A . Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-related construction.
Figure 1 Snorkel Filters Suppor t Leg J-Box T op Cap Blower Assembly Wing Nuts INTRODUCTION GENERAL DESCRIPTION The complete Universal Cook‘n‘Vent ® System consists of the ventilator intake and a blower .
STEP 1 PLAN THE INSTALLATION Carefully follow the planning procedures listed below. See Figure 2. A . Determine whether a remote or integral blower will be used. Remote blower installation requires 5 wires plus a ground wire to run from the Cook‘n’Vent ® to the blower.
Figure 2 • Be certain to avoid interference with gas and electric supply to cooktop . • Shelving and dra w er depths are dependent upon cooktop depth and setback.
FIGURES 3 THR OUGH 6 ARE EXAMPLES OF POSSIBLE DUCTING Figure 3 THROUGH W ALL INST ALLA TION Figure 4 INTEGRAL BLO WER VTN600CVA Ground 12" Min. Wall Cap WC8 Figure 5 THROUGH WALL DUCT INSTALLATIO.
Page 6.
T ABLE 2. DUCT W ORK INST ALLA TION GUIDELINES • Keep duct runs as short and straight as possible. • Duct fittings (elbows and transitions) reduce air flow efficiency. • Back to back elbows and "S" turns significantly reduces air flow and are not recommended.
Figure 7 TABLE 3 (in inches) UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS Table 3 Notes * Dimension "SB" is the minimum distance from the leading edge of the counter to the leading edge of the cutout.
I NSTALLATION WITH OTHER COOKTOPS WHERE SPECIFIED (SEE PART B) Figure 8 34-1/2" - UCV36 OW CW 28-1/2" - UCV30 1/8" OD CD SB 2-1/4" BT 43-1/2" - UCV45 The installer will need to have the cooktop installation instructions available to complete the installation.
STEP 3 PREPARE DUCT CUTOUTS IN CABINET T ABLE 4 INTEGRAL BLOWER VTN600CVA C D E F G H UCV30 7-1/2 6 1/ 4 15-1/2 9 - UCV36 7-1/2 6 1/ 4 15-1/2 9 - UCV45 7-1/2 6 1/ 4 15-1/2 9 - REMOTE BLOWER VTR600R OR VTR1000Q C D E F G H UCV30 7-1/4 6 - 12-1/4 12-1/4 3 UCV36 7-1/4 6 - 12-1/4 12-1/4 3 UCV45 7-1/4 6 - 12-1/4 12-1/4 3 Page 10 A .
STEP 6 MOUNT VENT & COOKT OP A. Remove grease filters and any packing materials from inside the intake. B. Set the vent intake into rear of countertop opening. Carefully lower it into position so that the flanges on the rear sides and edges fully support the unit hanging from the countertop.
STEP 7 MOUNT INTEGRAL BLOWER OR Remote Blower Transition MOUNT INTEGRAL BLOWER OR Remote Blower Transition Integral Blower VTN600CVA Only A. Place blower in front of intake inside of cabinet, take conduit and blower wires and guide them towards the right at the floor of the cabinet.
STEP 8 VERIFY INSTALLATION, OPERA TION & COOKT OP ALIGNMENT Before performing this procedure, verify that all packing materials were removed from inside the lower enclosure front and that the grease filters have been properly installed. Refer to the Care and Use Manual for instructions regarding filter instal- lation.
NO TES.
5551 McFadden Aven ue, Huntington Beach C A, 92649 • 800-735-4328 BSH Home Appliances Corp. • Litho in U.S.A. 10/02 5060004249 (8209).
An important point after buying a device Thermador UCV30 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Thermador UCV30 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Thermador UCV30 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Thermador UCV30 you will learn all the available features of the product, as well as information on its operation. The information that you get Thermador UCV30 will certainly help you make a decision on the purchase.
If you already are a holder of Thermador UCV30, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Thermador UCV30.
However, one of the most important roles played by the user manual is to help in solving problems with Thermador UCV30. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Thermador UCV30 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center