Installation Instructions for Thermador Char Glo ® Outdoor Barbecues Installer : Please lea v e these instructions with the unit for the owner . Owner : Please r etain these instructions for futur e refer ence.
Inside Front Co ver – Blank.
Page1 Contents SECTION 1: Safety Information ................................................................. 2 SECTION 2: Gas Requirements ................................................................... 3 Natural Gas Requirements ...............
Page 2 TESTED IN ACCORDANCE WITH ANSI Z21.58 – 1995, ANSI Z21.58a – 1998 STANDARD FOR OUTDOOR COOKING GAS APPLIANCES, AND CAN/CGA 1.6 – M95, CGA 1.6a – M98, STANDARD FOR OUTDOOR COOKING GAS APPLIANCES. This unit is for outdoor use onl y in a well-v entilated ar ea.
Page 3 NA TURAL GAS REQUIREMENTS - Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter. Supply Pressure: 6" to 14" W.C. Manifold Pressure: 5" W.C. PROP ANE GAS REQUIREMENTS - Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter.
For Massachusetts Installations: 1. Shut-off valve must be a “T” handle gas cock. 2. Flexible gas connector must not be longer than 36 inches. 3. Not approved for installation in a bedroom or a bathroom unless unit is direct vent.
Page 5 SECTION 3: SITE PREP ARA TION B UIL T -IN INST ALLA TIONS All Char-Glo ® Outdoor Barbecues are CGA and AGA approved. Note: All height width and depth dimensions are shown in inches. Determine a suitable location for the barbecue by taking into account exposure to wind and availability of gas and electrical supplies.
Page 6 SECTION 3: SITE PREP ARA TION To combustible construction - Below the cooking surface, combustible construction can be placed directly adjacent to the unit. Allow 8" clearance at the lower left rear of the unit for adequate routing of the gas and electrical supply line.
Page 7 Installation of electrical supply circuit should be done by a qualified electrician in accordance with local codes and ordinances. In the absence of local codes or ordinances, the supply should be installed in accordance with the National Electric Code ANSI/NFPA No.
Page 8 SECTION 5: UNP A CKING, MO VING AND PLA CING THE UNIT Leaving the unit on the pallet, move the unit close to the final installation site. Unpack and remove all accessory items, packing materials and product literature from inside the unit. Verify the gas supply type.
Page 9 SECTION 5: UNP A CKING, MO VING AND PLA CING THE UNIT FIGURE 6 FIGURE 7A FIGURE 7B 10. All barbecue models are supplied with a pressure regulator that is packed with the unit. The regulator is set for natural gas. For use with propane, it must be converted.
Page 10 11. If the barbecue will be used with an LP cylinder, follow these steps: C. The proper LP hose and regulator assembly must be used. The Model LPHOSE is available at your Thermador dealer. This assembly can also be purchased locally providing it meets the following specifications: Hose length to be 24".
Page 11 GAS AND ELECTRICAL HOOK-UP With the unit inside of the enclosure, connect the gas supply hose to the manual shut-off valve and open valve. Check the connection points at the shut- off valve for any leaks and repair prior to installation of the unit.
Page 12 All points of connection to the gas supply should be checked for leaks at time of installation or anytime you smell gas. It is also advisable to recheck them periodically. Follow the steps outlined below: A. Make a soap solution of one part liquid detergent and one part water.
Inside Back Cov er – Blank.
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328 ECO 14028 • 08-04-439D • © BSH Home Appliances Corp. • Litho U. S. A. 4/01 Specifications are f or planning purposes only . Refer to installation instructions and consult your countertop supplier prior t o making counter opening.
An important point after buying a device Thermador CGBD30RX (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Thermador CGBD30RX yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Thermador CGBD30RX - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Thermador CGBD30RX you will learn all the available features of the product, as well as information on its operation. The information that you get Thermador CGBD30RX will certainly help you make a decision on the purchase.
If you already are a holder of Thermador CGBD30RX, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Thermador CGBD30RX.
However, one of the most important roles played by the user manual is to help in solving problems with Thermador CGBD30RX. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Thermador CGBD30RX along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center