Instruction/ maintenance manual of the product 200 MAX Therma-Stor Products Group
Go to page of 11
1 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Owner’ s Manual — Phoenix 200 MAX Installation, Operation & Ser vice Instr uctions Read and Sav e These Instr uctions Phoenix 200 MAX TS-262C The Phoenix 200 MAX is one of the most effective and versatile dr ying devices a vailable.
2 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 1 Specifications P ar t No. 4024920 P ower 110-120 V ac, 7.4 amps; 851 watts W ater 133 pints/day @ AHAM (80°F , 60%) Removal 240 pints/day @ saturation 30 gal/da y maximum @ saturation Refrigerant 1 lbs.
3 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 • The air inlet on top & the side outlet must be at least 1 foot from walls and other obstructions to air flow . • If the humid area is ver y large, dehumidification can be improved b y adding an outlet duct to circulate air to stagnant areas (see Sec.
4 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 2.10 Low Pressure Control If the low side refrigerant pressure drops to 15 PSIG, the low pressure control opens and shuts off the compressor and blower . It is an automatically reset control.
5 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 The mixture of gas and liquid refrigerant enter the accumulator after lea ving the evaporator coil. The accumulator prevents an y liquid refrigerant from reaching the compressor .
6 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 5. Rotate the blower outlet tow ard you as you remove it. Use care to a void hooking wiring , tubing or electrical components. 6. Reassembling with the new blow er in the above procedure reversed.
7 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 If sludge is evident in the discharge line, it will likely be found in the suction line; this indicates the compressor burned out while r unning. Sludge and acid ha ve been pumped throughout the system.
8 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Figure 3: Electrical schematic of 200 MAX 5 Wiring Diagram.
9 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Item P ar t No. Qty . Description 1 4022254 1 Accumulator 4021475 1 Air F ilter , Pleated, 2” x 16” x 20” 65% Mer v-1.
10 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 This page intentionally left blank..
11 www .thermastor .com • sales@ther mastor .com T oll-F ree 1-800-533-7533 Phoenix 200 MAX Dehumidifier Limited W ar ranty W arrantor : Therma-Stor LLC PO Box 8680 Madison, WI 53708 T elephone: 1-.
An important point after buying a device Therma-Stor Products Group 200 MAX (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Therma-Stor Products Group 200 MAX yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Therma-Stor Products Group 200 MAX - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Therma-Stor Products Group 200 MAX you will learn all the available features of the product, as well as information on its operation. The information that you get Therma-Stor Products Group 200 MAX will certainly help you make a decision on the purchase.
If you already are a holder of Therma-Stor Products Group 200 MAX, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Therma-Stor Products Group 200 MAX.
However, one of the most important roles played by the user manual is to help in solving problems with Therma-Stor Products Group 200 MAX. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Therma-Stor Products Group 200 MAX along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center