T1 R emote Module Installa tion Link Wireless Telephone System Link 3000 MCU Part Number: 72-0059-06 Issue E.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU NOTICE SpectraLink Corporation has prepared this document for use by SpectraLink personnel and clie nts.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Note concerning the Master Control Unit: This equipment has been tested and found to comply with the l imits for a Class A digit al device, pursuant to Part 15 of the FCC Rules.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU UL Information This symbol on the nameplate m eans the product is listed by Underwriter’s Laboratories, Inc. It is designed and manufactured to meet rigid U.L. safety standards against X-radiation, fire, casualty, and electrical hazards.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU FCC Information The Master Control Unit Complies with Part 68, FCC Rules FCC Registration Numbers: Link 3000: IYGUSA-7385Q-PX-T Ringer Equivalence: Link 3000: 0.3B SpectraLink Corporation Link 3000 Made in the USA This equipment complies with Part 68 of th e FCC Rules.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Industry Canada (IC) Notice Notice: The Industry Canada (IC) label i dentifies certified equipment .
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Table of Contents 1. ABOUT THIS DOCUMENT 8 1.1 Contacting SpectraLink 8 1.2 Icons Used in this Document 8 1.3 Remote Installation Overview 9 1.4 Remote Installation Steps (Overview) 10 2.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1. About This Document This document explains installation of the SpectraLink Link Wireless Telephone System (Link WTS, MCS300) Remote T1 Module.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1.3 Remote Installation Overview Networking the Link WTS allows installation of expansion shelves at remote locations. T1 circuits are used to provide the connection from the System Controller shelf to each Remote Expansion shelf.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1.4 Remote Installation Steps (Overview) Follow these steps to install the T1 Remote Module. Detailed instructions for each of these steps are contained in this document and other relevant documents in the Link 3000 MCU System Documentation.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2. Site Prep aration The following steps must be completed before installing the system hardware. If the steps are not already completed refer to each individual section for details.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2.2 T1 Configuration Requirements T1 circuits will connect expansion shelves directly to the System Controller shelf via the SpectraLink provided Intershelf Junction Panel.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2.3 Check Components The following items should be at the installation site. Link 3000 MCU Expansion Shelves – (MCS300) – the number of shelves varies depending on the size of the system.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 3. Inst all T1 Remote Module at Local Site Before installing the hardware at the remote site, the Prim ary shelf at the local site must have a T1 Remote Module (CRC301) installed.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Network Clocked T1 Facilities If the T1 facilities are Network Clocked, one T1 Remote Module must be designated as the Master Clock Source. Connect the Sync IN port on this T1 Remote Module to AUX port A on the Intershelf Junction Panel.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU ALARM 1 2 3 4 5 CRC-301 TIMING MASTER IN SYNC OUT A B SYSTEM CONTROLLER SC/A SC/B EXP ANSION SHELF CONTROLLER DS1 A LOS.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 4. Inst all System at Remote Site 4.1 Survey Site Check the site to be sure pre-installation work has been completed correctly. This includes: • Location chosen for the shelves is adequate.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Do not install cards until power is connected. 4.3 Connect Power to Shelves SpectraLink recommends that a licensed electrician install the –48V DC power supply and connect power to the shelves.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU DISABLE ALARM 1 2 3 4 5 CONN A NORMAL DISABLE ALARM 1 2 3 4 5 CONN A NORMAL ALARM 1 2 3 4 5 RS-232 (RJ45) (RJ45) SC/A S.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU The following diagram shows the T1 Remote Module connections at the REMOTE site.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 4.7 Connect Demarc Block RJ-21 Cables to Interface Modules Connect the male RJ-21 connector from the appropriate dem arcation block to the designated RJ-21 connector ( A or B ) on each Interface Module.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 5. Configure Remote System Use the Operator’s Console to enter configuration information for the Remote Expansion Shelves. 5.1 Configure Remote Shelf 1. From the Operator’s Console, select F1 , Supervisor State Display .
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 5.2 Master Clock Configuration If the T1 facilities are Network Clocked, one shelf mu st be designated as the Master Clock Source. 1. From the Operator’s Console, select F8, Configuration Display and Administration .
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 6. Site Certification The installer should not leave the site before contacting SpectraLink to perform remote install verification.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7. Inst allation Forms This section contains the following forms: Base Station Locations Extension Assignments Site Preparation Checklist Customer Acceptance Form Copy these forms as needed.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7.1 Base Station Location Form Shelf Number: ________ Interface Module: ________ Base Station # Location (e.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7.2 Extension Assignments Worksheet Shelf: _______ Interface Module: _______ Phone # Ext.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7.3 Site Preparation Checklist If upon arrival the SpectraLink installer determines that the pre-installation work has .
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7.4 Customer Acceptance Form Customer Nam e: _______________________________________________________________________ Le.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Index Base station location form, 27 Cards Installing, 15, 19 Channel Service Unit, 13 Configuration Requirements T1, 1.
An important point after buying a device Texas Instruments 3000 MCU (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Texas Instruments 3000 MCU yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Texas Instruments 3000 MCU - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Texas Instruments 3000 MCU you will learn all the available features of the product, as well as information on its operation. The information that you get Texas Instruments 3000 MCU will certainly help you make a decision on the purchase.
If you already are a holder of Texas Instruments 3000 MCU, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Texas Instruments 3000 MCU.
However, one of the most important roles played by the user manual is to help in solving problems with Texas Instruments 3000 MCU. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Texas Instruments 3000 MCU along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center