Document No. 49-0002-013 Rev. A Installation, Operation & Diagnostics for the MIU9.6FPD Industrial Grade, Digital Fast Poll Standalone Modem.
Document No. 49-0002-013 Rev. A Telenetics Corporation 26772 Vista Terrace Drive Lake Forest, California 92630 (949)455-4000 Fax (949)455-4010.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 1 TABLE OF CONTENTS 1. STANDARDS .... ............................................................................ .............. 2 2. PRODUCT OVERVIEW .. .......................
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 2 1. STANDARDS Meets FCC Rules Part J, Subpart 15 , Class A for radi at ed emissions.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 3 2. PR ODUCT OV ERVIEW The MIU9.6FPD is an industri al grade Digi tal Fast Poll m odem designed for multidropping appli cat ions over unconditioned me tallic l ines (eg; pilot wires).
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 4 3. GENERAL PR ODUCT SPECIFICATIONS Dimensions: 5.3 x 4.0 x 1.375 inches Weight: 1 l b Voltage Supply : Standard Model : 40 to 270VDC 40 to 270VAC, 50/60Hz LV Model (Suffix “-LV” ): 9 to 36VDC Current Requirements : 12VDC 24VDC 125V DC 120VAC 220VAC MIU9.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 5 4. MODEM SPECIFICATIONS Modulation: Pulse Position Mo dulation ( PPM) Synch/Async: Asynchronous Only Data Rate: 0 – 1200bps Error Correction: None Data Compression: None Data Modulation Connectivity: Using 16m s Polli ng Test 99.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 6 Other Features Receiver Equali zation: Compromi se Equalizati on Self Test Diagnostics: None Local Analog Loopback: See Secti.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 7 5. METALLIC CONDUCTOR SP ECIFICATIONS The MIU9.6FPD contains di gital c irc ui try for connection 2 or 4-wire metal lic conductors (eg; pilot wires) . The M IU9.6FPD will also interface to Power Line Carrier or Mi crowa ve radio voice c hannel networks.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 8 6. POWER CONNECTIONS.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 9 7. SERIAL DATA PORT PIN-OUTS.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 10 8. DIP SWITCH FUNCTIONS IMPORTANT NOTE: Invert m odem t o vi ew dip switches as shown above Table 1 Switch Function ON OFF S.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 11 9. LED INDICATOR.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 12 10. OUTLINE DRAWING & MOUNTING.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 13 11. DIAGNOSTICS The following pages provide har dware techni ques for diagnosing comm unicati on problems and there by is olating the problem at the local mod e m, th e re mo t e mo d em o r the interconnecting line.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 14 Test 3: Received Signal Level Set Dip Switch 1 OFF (TxA = -10dBm ) and Dip Swit ch 3 OFF (RxA = -43dB m). CD will be ON. Run a test m essage a t TxD and verify that the sam e m essage is receive d at RxD with no data errors.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 15 (c) REMOTE DIGITAL LOOPBACK – 4/Wire Network (Figure 5) Configure both the local and re mote mo de ms a s f oll ow s: Swit.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 16 (d) LINE DIAGNOSTICS (i) Typical m odem configuration for 4-w ire Point-to-Point system… Switch 1 = ON (TxA = 0dBm ) Switch 3 = ON (RxA = -33dBm ) Switch 4 = OFF (RTS/CTS = 1ms) Switch 5 = OFF (RTS/CTS = 1m s) Switch 6 = ON (Constant Carrier m ode).
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 17.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 18.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 19.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 20 NOTES:.
An important point after buying a device Telenetics MIU9.6FPD (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Telenetics MIU9.6FPD yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Telenetics MIU9.6FPD - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Telenetics MIU9.6FPD you will learn all the available features of the product, as well as information on its operation. The information that you get Telenetics MIU9.6FPD will certainly help you make a decision on the purchase.
If you already are a holder of Telenetics MIU9.6FPD, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Telenetics MIU9.6FPD.
However, one of the most important roles played by the user manual is to help in solving problems with Telenetics MIU9.6FPD. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Telenetics MIU9.6FPD along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center