Installation, Operation & Diagnostics for the MIU/PowerPort Series / 2.4 / 9.6 / 14.4 / 28.8 Industrial Grade Dial Modems Book 1 of 2 (See Book 2 for AT Commands) Document No.
Telenetics Corporation 26772 Vista Terrace Drive Lake Forest, California 92630 Telephone (949)455-4000 Fax (949)455-4010 Document No. 49-0002-002.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 1 TABLE of CONTENTS 1. STANDARDS .................................................................................... Page 2 2. PRODUCT OVERVIEW .............................
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 2 1. STANDARDS All Telenetics di al-up modem s are designed to meet the following Standards: USA: FCC Part 15, Class A and .
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 3 2. PRODUCT OVERVIEW The MIUPowerPortX.X Series are i ndustrial grade dial and leased line modem s for connection to the Public Swit ched Telephone Network.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 4 Industrial: The MIU PowerPort is packaged in a rugged, compact, non-metallic (ABS) enclosure.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 5 3. GENERAL PRODUCT SPECIFICATIONS Dimensi ons: 5.3 x 4.0 x 1.375 inches Weight: 1 lb Voltage Supply: : 8 to 24 VDC 7 to 16 VAC, 50/60 Hz Optional Wall Transform er 115 VAC, 50/60 Hz Current Requirem ents: (See Section 4 for Power Down M odes) MIU PowerPort 2.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 6 4. POWER MODES Mode Description Power Consumption Power On Factory Setting : Full power is always available to the modem. See Section 3 Sleep If the modem is on hook for a predetermined peri od (PE2400 = 5 seconds; PE2496, PE14.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 7 5. MODEM SPECIFICATIONS MIU2.4 MIU9.6 MIU14.4 MIU28.8 Standards V.22bis V.22 Bell212A Bell 103 V.22bis V.22 Bell212A Bell 103 V.32bis V.32 V.22bis V.22 Bell212A Bell 103 V.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 8 6. POWER CONNECTIONS DC Power Jack, 2.0mm – This standard concentri c jack is provided to attach an external power source in the range of 7 – 16 VAC or 8 – 24 VDC . The 2.
7. SERIAL DATA PORT PIN-OUTS MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 9.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 10 8. DIP SWITCH SETTINGS Not Applicable – The dip switches are on the PE Modul e. Contact factory for non – standard settings. * NOTE: Opening the MIU for any reason voids t he factory warranty.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 11 9. LED INDICATOR The MIU has a single LED that w ill indicate the following conditions.
12. OUTLINE DRAWING & MOUNTING MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 12.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 13 13. MODEM CONFIGURATION Telenetics dial and leased l ine modems are based upon Rockwell chipsets. These chipsets contain Rockwell’s “AT” comma nd set. A summary of the Rockwell comm and set for your MIU m odem is provided in Book 2.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 14 14. FACTORY CONFIGURATION ~ MIU2.4 ACTIVE PROFILE: B1 E1 L2 M1 Q0 V1 X4 Y0 &C1 &D0 &G0 &J0 &L0 &.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 15 14. FACTORY CONFIGURATION ~ MIU9.6 ACTIVE PROFILE: B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D2 &G0 &J0 &.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 16 14. FACTORY CONFIGURATION ~ MIU14.4 ACTIVE PROFILE: B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D2 &G0 &J0 &.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 17 14. FACTORY CONFIGURATION ~ MIU28.8 ACTIVE PROFILE: B0 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D0 &G2 &J0 &.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 18 15. DIAGNOSTICS The following pages provide softwa re and hardware t echniques for diagnosing comm unication problem s and thereby isol ating the problem at either the local modem, the remote modem or the interconnecting lin e.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 19 &T0 TERMINATE TEST IN PROGRESS If a V.54 loopback test is in progress as a resul t of executing an &Tn command, then the &T0 command will cause that test to be terminated, provided that the modem is in the comm and state or a V.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 20 &T2 NO FUNCTION &T3 PERFORM LOCAL DIGITAL LOOPBACK (See Figure 3) The modem must be in the comm and state with connection est ablished when this command is issued, otherw ise an ERROR result code occurs.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 21 &T5 DENY RDL REQUESTS The modem will not respond to a rem o te digital loopback request from a distant modem. This will result in an error if the command is given wh ile any V.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 22 This is a system test, end to end. The comm and is valid only i f the mode m s are in the comm and state with a connection established. Configure th e remote modem with an AT&T4 comm and so that it will honor a remote digi tal loopback request.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 23 &T8 LOCAL LOOPBACK WITH SELF TEST (See Figure 6) The modem should be on hook. Enter AT&T8 to configure the m odem for analog loopback and self test. The t est timer i s started at the ti me indicated by S18, DSR i s turned off (i f &S1 is in effect).
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 24.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 25.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 26.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 27 ADDITIONAL TEST / DIAGNOSTICS COMMANDS... %L RECEIVED SIGNAL LEVEL Returns a value (-dBm) which indicates the received signal level at modem DATA PUMP interface.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 28 0 Normal hang up; no error occurred. 4 Physical carrier loss. (Loss of Carrier) 5 Feature negotiation fai led to detect presence of another V.42 error-control modem at other end.
MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 29 NOTES:.
An important point after buying a device Telenetics 14.4 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Telenetics 14.4 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Telenetics 14.4 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Telenetics 14.4 you will learn all the available features of the product, as well as information on its operation. The information that you get Telenetics 14.4 will certainly help you make a decision on the purchase.
If you already are a holder of Telenetics 14.4, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Telenetics 14.4.
However, one of the most important roles played by the user manual is to help in solving problems with Telenetics 14.4. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Telenetics 14.4 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center