Instruction/ maintenance manual of the product DR500 Superior
Go to page of 20
1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. HOMEOWNER'S CARE AND OPERA TION INSTRUCTIONS VENTED GAS FIREPLACE HEATERS - DIRECT VENT MODELS P/N 725,032M REV.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. These appliances are designed to operate on natural or propane gas only. Input of millivolt models is variable.
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. CAUTION: DO NOT ATTEMPT TO TOUCH THE FRONT ENCLOSURE GLASS WITH YOUR HANDS WHILE THE FIREPLACE IS IN USE. Variable Flame Height Adjustment ( Millivolt Appliances only) 1. All Millivolt appliances are equipped with a variable gas control valve.
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Periodically (After the Burning Season) Maintenance Task Accomplishing Person Procedure Cleaning Firebox Interior Check Flame Patterns and Flame Heig.
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Front Glass Enclosure Panel, Removal and Installation. ENSURE THAT THE FRONT GLASS PANEL IS IN PLACE AND SEALED DURING ADJUSTMENT. Adjustment CAUTION: THE ADJUSTMENT ROD AND NEARBY APPLIANCE SURFACES ARE HOT.
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Log Placement WARNING: THE SIZE AND POSITION ON THE LOG SET WAS ENGINEERED TO GIVE YOUR APPLIANCE A SAFE, RELIABLE AND ATTRACTIVE FLAME PATTERN. ANY ATTEMPT TO USE A DIFFERENT LOG SET IN THE FIREPLACE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE COMBUSTION, SOOTING, AND POOR FLAME QUALITY.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Electronic Appliance Checkout To light the burner, refer to the lighting instruc- tions on page 14 and 15 . Ensure the ignitor lights the pilot. The pilot flame should engulf the flame sensor as shown in Figure 12.
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Rocker Switch Kit 80L41 FRS Unit-Mountable Rocker Switch This rocker switch kit can be installed directly in the gas valve mounting bracket (millivolt gas valve equipped fireplaces) to provide On/Off operation in lieu of a wall switch.
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Clean faced panel kits are available to con- vert the standard louvered fireplaces to radi- ant models which are more suited for finish- ing around the firebox opening with non- combustible materials, such as tile.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D ’ ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT INSTRUCTIONS D'ALLUMAGE 8.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly.
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D ’ ALLUMAGE — ELECTRONIC INSTRUCTIONS D ’ ALLUMAGE POUR VOTRE S É CURIT É , LISEZ CES INSTRUCTIONS AVANT L ’ ALLUMAGE A. Lorsque vous allumez l’appareil, suivez exactement ces instruc- tions.
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TROUBLESHOOTING THE MILLIVOL T GAS CONTROL SYSTEM 1. Spark ignitor will not light pilot after repeated triggering of ignitor button. 2. Pilot will not stay lit after carefully following the lighting instructions.
17 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION See Below. Disconnect the two black wires from the wire nuts. Test switch(s) for continuity with a multimeter.
18 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. REPLACEMENT PARTS LIST GAS CONTROLS — ELECTRONIC GAS CONTROLS — SIT MILLIVOLT GAS CONTROLS — HONEYWELL MILLIVOLT . o NN O I T P I R C S E D l a r u t a Ne n a p o r P . o N t r a P. y t Q. o N t r a P.
19 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. REPLACEMENT PARTS 4 2 1 13 2 5 41 40 21 14 12 6 43 23 22 24 42 3 26 25 30 31 32 33 34 35 15 D, DT , DR-500 16 36 11 27 37 20 10 8 D, DT , DR-600 D, .
20 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2002 by Lennox Hearth Products P/N 725,032M REV. H 11/2004 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
An important point after buying a device Superior DR500 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Superior DR500 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Superior DR500 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Superior DR500 you will learn all the available features of the product, as well as information on its operation. The information that you get Superior DR500 will certainly help you make a decision on the purchase.
If you already are a holder of Superior DR500, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Superior DR500.
However, one of the most important roles played by the user manual is to help in solving problems with Superior DR500. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Superior DR500 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center