Sun Microsystems, Inc. www .sun.com Submit comments abou t this document a t: http://www.s un.com/hwdocs/feedback Sun Fire ™ X4100/X4100 M2 and X4200/X4200 M2 Ser v ers Installation Guide P art No.
Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 9505 4, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectu al property rights relating to technology tha t is described in this document. In particula r , and without limitation, these intellectual property rights may include one or mo re of the U.
iii Contents Preface v 1. Setting Up the Server Hardware 1 Installation O verview 1 Installing the Server Into a Rack W ith Optional Slide Rails 2 Disassembling the Slide Rails Before Installation 3 I.
iv Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 2. Setting Up the Server Software 19 Introduction to the Integrated Ligh ts Out Manager 19 Connecting to the ILOM .
v Pr eface This Installati on Guide conta ins procedur es for installing the server in a rack, cabling, and powering on the server . It also contains pr ocedur es for connecting to the servi ce proc essor administrator account.
vi Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Pr oduct Updates For pr oduct updates that you can download for the Sun F ire X4100 or X42 00 servers, please visit the following W eb site: http://www.sun.com/servers/entry/x4100/ downloads.
Preface vii T ypographic Conventions Sun W elcomes Y our Comments Sun is inter ested in improving its docu mentation a nd welcomes your comments and suggestions.
viii Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007.
1 CHAPTER 1 Setting Up the Server Har dware This chapter contains the following topics: ■ “Installation Overview” on pa ge 1 ■ “Installing the Server Into a Rack W ith Optional Slide Rails.
2 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 5. Configure the pr einstalled Solaris™ operating system or install a supported operating system of your choice.
Chapter 1 Setting U p the Ser ver Hardware 3 Disassembling the Slide Ra ils Before Installation Use this procedure to r emove the mounting brackets from the slide-rail assemblies. 1. Unpack the sl ide-rails. 2. Locate the slide-rail l ock at the fron t of one of the slide-rai l assemblies, as shown in FIGURE 1- 1 .
4 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Installing the Mounting Brackets Onto the Server Use this procedure to install the mounting brackets o nto the sides of the server .
Chapter 1 Setting U p the Ser ver Hardware 5 Attaching the Slide-Rail Assemblies to the Rack Use this pr ocedur e to install the slide-rail assemblies to the rack. 1. Position a slide-rail assembly in your rack so that the brackets at each end of the slide-rail assembly are on the outside of the front and rear rack posts.
6 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Installing the Server Into the Slide Rail Assemblies Use this procedure to instal l the server chassis, with mounting brackets, into the slide-rail assemblies that ar e mounted to the rack.
Chapter 1 Setting U p the Ser ver Hardware 7 4. Simultaneously pull and hold th e slide rail release buttons on each mounting bracket while you push the server into the rack. See FIGURE 1-4 . Continue pus hing until the s lide-rail lo ck s on the front of the mounting brackets engage the slide-rail assemblies.
8 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 4. V erify that the CMA rail extension engages the sli de-rail, as shown in FI GURE 1-6 . FIGURE 1-6 Detail of CMA Rail Extension Inse rted Into the Left Slide-Rail Note – Support the CMA in the remaining inst allation steps.
Chapter 1 Setting U p the Ser ver Hardware 9 FIGURE 1-7 Inserting the CMA Mounting Bracket Into the Rear of the Right Slide-Rail 6. Insert the right CMA slide-rail connector into the ri ght slide-rai l assembly until the connector locks into plac e with an audible click.
10 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 7. Insert the remaining CMA arm connector into the plastic cutout on the CMA rail extension, which you installed to the left slide- rail in Step 3 . See FI GURE 1-9 .
Chapter 1 Setting Up the Ser v er Hardware 11 FIGURE 1-10 Installing CMA Cable Hangers Attaching and Routing Cables Use this procedure to attach cables to yo ur server and r oute them through the CMA. 1. Refer to “Cabling” on p age 13 for an illustration of the server back panel ports and a procedure for installing cables to your server .
12 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 V erifying Operation of the Slide Rails and CMA Use this procedure to ensur e that the sl ide-rails and CMA ar e operating correc tly .
Chapter 1 Setting Up the Ser v er Hardware 13 Cabling Attach cables to the back pan el connectors of your server as r equired. See FIGUR E 1- 1 1 or FIGURE 1- 12 . FIGURE 1-11 Sun Fire X4100/X4100 M2 Server Back Panel FIGURE 1-12 Sun Fire X4200/X4200 M2 Server Back Panel 1.
14 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 3. If desired, connect a vi deo moni tor cable to th e video connector . Note – Keyboard, mouse, and video ar e option al with an operating system that supports headless operation.
Chapter 1 Setting Up the Ser v er Hardware 15 5. If desired, conne ct an RJ-45 serial po rt cable to the “SERIAL MGT” connector . Note the following considerations for th e serial port and serial port cabling: ■ The default serial port speed is 9600 baud with no flow contr ol.
16 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Powering On and Of f the Server Y ou have to apply only standby power to th e server at this point so that you can perform initial configuration o f the service processor .
Chapter 1 Setting Up the Ser v er Hardware 17 Powering On Main Power Mode ● T o power on main power for all server components: a. V erify that power cor ds have been co nnected and that standby power is on. In standby power mode, the Power/OK LED on the front pa nel flashes.
18 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 ■ Emergency shutdown: Pr ess and hold the Power button for four seconds to force main power off and enter stan dby power mode.
19 CHAPTER 2 Setting Up the Server Softwar e This chapter descri bes the tasks for initial setup of the server ’s service pr ocessor and Integrat ed Light s Out Manager™ so ftwar e .
20 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 ILOM consists of four components, three of which ar e on your host server and one that is on the client sys tem that accesses your host server . The four components are as follows: ■ ILOM SP hardware.
Chapter 2 Setting Up the Ser ver Software 21 Connecting to the ILOM Service Pr ocessor There ar e two methods for connect ing to th e ILOM SP to perform initial setup and configurat ion.
22 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 4. Press Enter on the terminal device to esta blish a connection between that terminal device and the ILOM SP .
Chapter 2 Setting Up the Ser ver Software 23 C o n n e c t i n g t o I L O M U s i n g a n E t h e r n e t Connection T o access the full range of ILOM functiona lity such as the graphical user interface (GUI), you must connect a LAN to the Ethe rnet port and configure your Ethernet connection.
24 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 a. Identi fy the MAC address of the ILOM SP from one of the following locations and write it down: ■ CLI commands. The SP has a serial port to which you can attach a termina l device.
Chapter 2 Setting Up the Ser ver Software 25 FIGURE 2-2 Opening a Session W ith an SSH Command-Line Interface ■ T o establish a connection to the ILOM SP web GUI, type the IP address of the ILOM SP in the browser locator box and pr ess Enter . For example, if the IP address for your ILOM SP was 129.
26 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Configuring ILOM Using Static Ethernet Settings As an alternative to having your DHCP server assign an IP addr ess to your ILOM SP , you can also assign a static IP address to it.
Chapter 2 Setting Up the Ser ver Software 27 FIGURE 2-4 Integrated Lights Out Manager Network Settings Page Configuring Static IP Addr esses Using the CLI 1.
28 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Configuring Static IP Addr esses Using the BIOS Setup Utility 1. Enter the BIOS Setup u tility by pressing the F2 key while the system is bootin g up and performing the power- on self-test (POST).
Chapter 2 Setting Up the Ser ver Software 29 Setting Up Platform Operating System and Driver Softwar e After configuring the ILOM SP with ne twork settings, you can configure the prein stalled Solaris 10 operating system, or install a sup ported Linux or W indows platform operating system an d drivers.
30 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007.
31 CHAPTER 3 Configuring the Pr einstalled Solaris 10 Operating System This chapter explains the step s for configuring the Solaris ™ 10 Operating System (OS) that has been prei nstalled on your server . The factory-installed version is Solaris 10 6/06 or later .
32 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Installation W orksheet Use the worksheet in TA B L E 1 to gather the information you need to configure the preinstalled Solaris 10 OS. Y ou need to coll ect only the informati on that applies to your applicatio n.
Chapter 3 Configuring th e Preinstal led Solaris 10 Oper ating System 33 Name service: if the system uses a name service, pro vide th e following information. Name service Which name service should this syst em use? • NIS+ •N I S •D N S •L D A P •N o n e * Domain name Pro vide the name of the domain in whi ch the system res id es .
34 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Default route Do you want to specify a default ro ute IP address or let the Solaris in stallation pr ogram find one? The default rout e provides a bridge that forwards traffic between two phys ical networks.
Chapter 3 Configuring th e Preinstal led Solaris 10 Oper ating System 35 Selecting Y our Console Output Unlike with SP ARC ® systems, you wil l not see the output of the preinstalled Solaris 10 image through a monitor when you power on the server . Instead, the output of the preinstalled image is dir ected to a serial console .
36 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 Configuring the Pr einstalled Solaris 10 Operating System Note – Before you perform this pr ocedure, you need to set up the service pr ocessor . If you have not done so, see “Before Y ou Begin” on page 31 .
Chapter 3 Configuring th e Preinstal led Solaris 10 Oper ating System 37 ▼ T o Connect to the Server Using the Service Pr ocessor ’s IP Address Note – This pr ocedure as sumes that you have connected the server to your network throug h an Ethernet cable.
38 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007 The screens that ar e displa yed will vary , depending on the method that you chose for assigning network in formation to the server (DHCP or static IP addr ess).
Chapter 3 Configuring th e Preinstal led Solaris 10 Oper ating System 39 After you have entered the system-configura tion information, the server completes the boot proces s and displays the Sol aris login pr ompt. Solaris 10 User Documentation Y ou can access the various collections of the Solaris 10 OS use r documentati on at: http://docs.
40 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Installation Guide • May 2007.
41 Index B back panel cable connectors 13 back panel illustration 13 C cable management assembly 7 cables 13 Cisco 72-3383-01 console cable 15 client-side secure shell 20 CMA assembly 7 connectors, ba.
42 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Ser vers Installation Guide • Ma y 2007 P power powering off 17 powering on main power 17 powering on standby power 16 product upda tes vi R rack instal.
An important point after buying a device Sun Microsystems Sun Fire X4100 M2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sun Microsystems Sun Fire X4100 M2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sun Microsystems Sun Fire X4100 M2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sun Microsystems Sun Fire X4100 M2 you will learn all the available features of the product, as well as information on its operation. The information that you get Sun Microsystems Sun Fire X4100 M2 will certainly help you make a decision on the purchase.
If you already are a holder of Sun Microsystems Sun Fire X4100 M2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sun Microsystems Sun Fire X4100 M2.
However, one of the most important roles played by the user manual is to help in solving problems with Sun Microsystems Sun Fire X4100 M2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sun Microsystems Sun Fire X4100 M2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center