Instruction/ maintenance manual of the product R59770263/06 Barco
Go to page of 37
DMP-1 00 Installation Guidelines R59770263/06 15/09/2011.
Barco n v Media & Entertainment D ivision Noordlaan 5, B-8 520 Kuurne Phone: +32 56.36.82.11 Fax: +32 56.36.883.86 Support: www.barco.com/esupport Visit us at the web: www.
Changes Barco provides this manual ’as is’ without warranty of any kind, either expressed or implied, including but not limited to the implied war- ranties or merchantability and fi tness for a particular purpose.
.
Tabl e of c ont ent s T ABLE OF C ONTEN TS 1 . S a f e t y ...... ...... .... .... ...... .... .... ...... .... .... ...... .... .... ...... .... .... ...... .... .... ...... .... .... ...... .. 3 1.1 Important Safety Instructions ....................
Tabl e of co nt ent s 2 R59770263 DMP-100 15/09/2011.
1. Safety 1. SAFETY 1.1 Important Safety Instructions Instructio ns: • Read these instructions. • Keep the se instructions. • Heed all warnings. • Follow all instructions. • Do NO T subm erge fully or partly in water or other liquids. • Clean only with materials or chemicals that are inert, nonabrasive, noncorrosive and non-marking.
1. Safety • Maximum am bient temperature: The maximum recommended ambient temperature for t his equipment is 50° C. • Flammable m aterials: Keep fl amm able materials away from the instal lation (such as curtains). A lot of energy is transferred into heat.
2. Introdu ct ion 2. INTROD UCTION Overview • General functionality • Order info DMP-100 processor • Content of a DMP-100 package • T ec hnical summary • Dimen sions of the DMP-100 processor • Com ponents of the DMP-1 00 processor 2.
2. Introduc tion 2.2 Orde r info DMP-100 proces sor Order info: Article number Description R9828833 DMP-100 processor 2.3 Content of a DMP- 100 package Packa ge 1 2 3 4 Image 2-3 1 Protecti ve cover for the DMP-100 processo r and installati on manual.
2. Introdu ct ion 2.4 T echnical summary Summary Ty p e V a l u e Input DVI input (supported resolutions 800x600 / 1024x768 / 1600x1200) Compatibility Barco DVI based LED walls, S 10XP FX or newer (Barco NNI tiles are not supported) Output DVI-A, Barco LED protocol.
2. Introduc tion 2.5 Dimens ions of the DMP-100 processor Dimensions of the DMP-100 processor 1 10 mm 250 mm 266 mm 1 10 mm 250 mm 262.4 mm 56 mm 1.5 mm Image 2-4 2.
2. Introdu ct ion 4 Cooling fan s. 5 Soft support s. 6E T L c e r t i fi cat ion label. R59770263 DMP-100 15/09/2011 9.
2. Introduc tion 10 R59770263 DMP-100 15/09/2011.
3. P hysica l instal latio n of the DM P-100 pr ocess or 3. PHYSICAL INST ALLA TION OF THE DMP-100 PROCESSOR Overview • Installation requirements • Connections of the DMP-100 processor 3.
3. Ph ysica l install ation of the DMP- 100 proces sor 3.2 Connections of the DMP-10 0 processor Front panel connections 1 2 3 4 5 6 7 8 9 10 11 Image 3-2 Nr .
3. P hysica l instal latio n of the DM P-100 pr ocess or W ARNING : The power connection is located on the back side of the DMP -100 processor and includes an inte gr ate d int err up tio n sw itc h.
3. Ph ysica l install ation of the DMP- 100 proces sor 14 R59770263 DMP-100 15/09/2011.
4. Cables f or the DMP-100 pr ocess or 4. CABLES FOR THE DMP-100 PROCESSOR 4.1 Ca bles List with a vailabl e cables Article number Description Image Z3499213 Used to connect a LE D-W ALL and a Barco display . (T-16/TF-16/SP- 20/S14/T20/TF-20/SLITE/S10XP) Image 4–1 R326103 Power cable with CEE7 plug.
4. Cables for th e DMP -100 process or 16 R59770263 DMP-100 15/09/2011.
5. Embed ded PC 5. EMBEDDED PC Overview •C o n fi guration • Embedded PC operating system, settings •S p e c i fi cations of the em bedded PC 5.1 Con fi gura tion Con fi guration of the embedded PC The embedded PC is a powerful built-in PC which is used as control PC.
5. Embedded PC W ARNING : The Play PC is always used as default. If the Play PC does not exist or h as been damaged, the DMP-100 processor w ill automatically use the embedded P C as a back up solution. If the play PC has b een damaged , a noti fi cation will b e given by the used control software.
5. Embed ded PC Or , cli ck Start → Control panel .F r o m t h e Classic View of that panel, double click on Date and Time . Image 5-3 2. Click on Time Zon e tab. 3. Click on the drop down list to select the time zone that corresponds to the time zone where the DMP-100 is being installed.
5. Embedded PC Image 5-4 3. Click on the H ardware ta b (2 ). 4. Make sure the disk drive corr esponding to the C: drive is selec ted in the All disk drives section (3 ). 5. Click Properties (4). 6. Click on the Po licies tab (6). 7. Uncheck the Enab le write caching on the disk box (7).
5. Embed ded PC Enhanced IDE interface ICH7M support Single, independent IDE signal channel Supports one CF device Serial ports T wo serial RS-232 ports, COM1(RS -232), DB-9 COM2(RS-232/422/485) Paral.
5. Embedded PC 22 R59770263 DMP-100 15/09/2011.
6. Confi gura tion s cheme 6. CONFIGURA TION SCHEME 6.1 Overvie w Sche me DVI input Formated V ideo Data SOURCE 1 Optional Control PC DMP-100 Display SOURCE 2 Remote control through TCP/IP ** ** Image 6-1 *T h e fi berlink is optiona l. ** Default co nnection.
6. Configur atio n sch eme Image 6-3 3. Turn on the power of the DMP-100. Note: The Led’ s indicated with “PWR” and “MCU” will li ght up. 4. Use the REAL VNC application on the rem ote PC to login to the embedded P C. 5. U se the RMS control software to communicate with the DM P-100 processor .
6. Confi gura tion s cheme If a d ispl ay or bi ll board i s up and running, th e user c an start from ste p 3. Connect the control PC with the DMP-100 processor , using a USB li ne on the USB-UART port, to update t he software and fi rmware used by the DMP -100 processor through the embedded Flash Load er software.
6. Configur atio n sch eme Alternatively , s tep 2 and 3 can be carri ed out together by pushing the reset button. Use the Flash Loader softwa re to downlo ad updates on the softw are and fi rmw are used by the DMP-100 pro - cessor .
7. Contr ol so ftw are 7. CONTROL SOFTW ARE 7.1 RMS General introduc tion RMS control software is running on the embedded PC inside DM P-100 to con fi gure and control the DMP-10 0 and as sociated LED wall from basic set-up to advanced features such as input timing, bright ness control setup and monitoring tools.
7. Contr ol softwar e Image 7-2 3. Click Commu nication > RS232 Con fi g > Baud , and select 38400 . 4. Click Communicati on > RS232 Con fi g > COM Port , and select the COM port on the PC to whic h the DMP-100 is connected.
8. Mainte nance 8. MAINTENANCE 8.1 Cleaning the cabinet C AUTION : Do not use liquid cleaners or aerosol cleaners. Never use strong solvents, s uch as thinner or benzine, or abrasive cleaners, since these w ill damage the cabinet. Necessary t ools Damp cloth.
8. Maintenan ce 30 R59770263 DMP-100 15/09/2011.
9. E nviron mental inf ormation 9. ENVIRONMENT AL INFORMA TION 9.1 Disposal informa tion Disposal Information This equipment has required the extract ion and use of natural res ources for its producti on. It may c ontain hazardous substances for health and environment.
9. Envir onmenta l info rmation 32 R59770263 DMP-100 15/09/2011.
Revision S heet To : Barco nv Media & Entertainment Division/Documentation Noordlaan 5, B-8520 Kuurne Phone: +32 56.36.82.1 1, F ax: +32 56.36.88.24 Support: www .
An important point after buying a device Barco R59770263/06 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Barco R59770263/06 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Barco R59770263/06 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Barco R59770263/06 you will learn all the available features of the product, as well as information on its operation. The information that you get Barco R59770263/06 will certainly help you make a decision on the purchase.
If you already are a holder of Barco R59770263/06, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Barco R59770263/06.
However, one of the most important roles played by the user manual is to help in solving problems with Barco R59770263/06. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Barco R59770263/06 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center