XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 1of 36 Operating Instructions Single Conveying Units Compressed Air Venturi Type SSV-05 SSV-05R SSV-052R Bulletin No.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 2 of 36 The manufacturer retains all rights to change th e information in these operating instructions at any time without notice. We assume no liability for any errors or direct or indirect damage resulting in context with these operating instructions.
Please note that our address and phone i nformation has changed. Please reference this page for updat ed contact information. These manuals are obsolet e and are provided only for their technical information , data and capacities.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 3 of 36 Table of Contents CHAPTER 1: SAFETY INSTRUCTIONS.. . . . . . . . . . . . . . . . . . 4 1.1. Warnings and Symbols .........................................................
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 4 of 36 Chapter 1: Safety Instructions » These safety instructions apply to anyone near the equipment operation. Please inform everyone near the operating equipment about the direct and indirect hazards associated with the equipment.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 5 of 36 1-1 Warnings and Symbols The following warnings and symbols are used in these operating instructions. » This symbol indicates that a technical term is explained at this point.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 6 of 36 1-2 Explanations and Information Various terms and designations are used frequently in these operating instructions to ensure clarity.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 7of 36 1-3 For Your Safety How to Use This Manual • Please read this manual carefully before initial operation. Understandin g the instructions and equipment will help to avoid injuries as well as damage to equipment.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 8 of 36 • Check all lines, hoses, and coupling pieces regularly for leakage and damage. Any errors must be eliminated immediately. • The unit may only be used if all corresponding components have been properly connected and are in accordance with relevant regulations.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 9 of 36 1-4 Unit Safety • The unit may ONLY be used for conveying cylindrical plastic granules and regrind on injection molding machines. • NEVER change the settings unless you are able to foresee the consequences.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 10of 36 Chapter 2: Inst allation » These installation instructions are intended for people with skills in electrical and mechanical areas due to their training, experience and received instructions.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 11 of 36 2-1 General Information Unpack all parts of the single conveyor unit and make sure that every thing is available: • .
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 12 of 36 2-2 Installing the Conveyor Hopper The single conveyor unit is insensitive to shocks and can be installed d irectly on the processing machine. Make sure that all connections are tight so that the conveying performance is not impaired.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 13 of 36 2-3 Installing the Control and Maintenance Unit Install the control and maintenance unit at a freely accessible site. Check the length of the connection cable and the length of t he supplied hoses to the venturi assemblies.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 14 of 36 2-4 Connecting the Comp ressed Air Supply Before connecting the compressed air supply, check the following: Check compressed air piping for correct installation and assembly.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 15 of 36 2-5 Electrical Connection The operating voltage is 110 V, AC, PE, 50/60 Hz. Special voltages available by request. The connected load is approximately 15 W. The connection is made using a mains connector.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 16of 36 Chapter 3: Functional Description 3-1 Method of Functioning The single conveyor unit works according to the Venturi Principle. An external compressed air supply is needed.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 17 of 36 3-2 Control and Maintenance Unit A. The unit is switched ON and OFF at the control and maintenance unit. B. At the regulator, the operating pressure is adjusted. A water separator is integrated.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 18of 36 This chapter is intended for t he operating personnel of the equipment. General knowledge of operating c onveyor units is required. The functional description must be read and understood.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 19 of 36 4-3 Basic Setting of the Filling Level in the Conveyor Hopper The filling level in the conveyor hopper is mainly determined by the level sensor. Figure 6: Conveyor Hopper Filling Level Too Low 1.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 20 of 36 Fine Adjustment of the Filli ng Level in the Conveyor Hopper During operation, use a screwdriver to carefully turn the adjustment screw (A) of the level sensor until the desired filling level is reached.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 21of 36 Chapter 5: Maintenance This chapter is intended for persons with skills in electrical and mechanical areas due to their training and experience.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 22 of 36 5-1 Maintenance Intervals Check the setting of the pressure regulator. Empty the water separator. Daily: Check danger signs on the unit for legibility and completeness. Clean the cartridge filter and screen (depending on accumulation of dust).
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 23 of 36 5-2 Cleaning/Replacing the Filter Cartridge Switch the unit OFF . Disconnect the main electrical plug.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 24 of 36 Disassembly 1. Remove the filter cartridge (A). 2. Blow out the filter cartridge (A) from the inside out using compressed air or replace the filter. 3. Open the toggle-type fastener (B) and fold the hopper lid upward (C).
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 25 of 36 5-4 Troubleshooting PROBLEM REMEDY (See Test Steps Below) The unit is not conveying and is not active. A, B, G, H The unit is not conveying; the compressed air valve is switched when the device is switched on.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 26 of 36 -Notes-.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 27of 36 Chapter 6: T echnical Dat a Maximum througput: 330 lbs/h (149.7 kg/hr) Weight: Approx. 6.61 lbs. (3 kg) Operating voltage: 110 V, AC, PE, 50/60 Hz (standard) Special voltage on request Connected load: Approx.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 28 of 36 6-1 Dimension Sheet XSV-05.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 29 of 36 XSV-05/R Dimensions and data are not binding. All dimensions are in mm (in.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 30 of 36 XSV-05/2R s Dimensions and data are not binding. All dimensions are in mm (in.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 31 of 36 6-2 Spare Parts Lists XSV-05.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 32 of 36 . XSV-05R.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 33 of 36 XSV-05/2R.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 34 of 36 Spare Parts List (See figures on previous pages for parts location) Position ID Number Designation 1 CT98171 Filter ca.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 35 of 36 6-3 Quick Start Guide –XSV Venturi Loader Unpack all parts. Check for the following: • Conveying hopper with level.
XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 36 of 36 6-4 Technical Assistance Parts Department Call toll-free 7am–5pm CST [ 800 ] 423- 3183 or call [ 630 ] 595-1060, Fax.
An important point after buying a device Sterling SSV-05 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sterling SSV-05 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sterling SSV-05 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sterling SSV-05 you will learn all the available features of the product, as well as information on its operation. The information that you get Sterling SSV-05 will certainly help you make a decision on the purchase.
If you already are a holder of Sterling SSV-05, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sterling SSV-05.
However, one of the most important roles played by the user manual is to help in solving problems with Sterling SSV-05. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sterling SSV-05 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center