INS TRUCT ION MANUAL FOR SPEEDO TRON BROWN LINE EQUIPMENT .
2 3 T ABLE OF C ONTENT S Power Supplies General Information – Read This First . . . . . . . . . . . . . . . . . . . 4 Models D604, D1204, D1604 Description of Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operating Instructions .
4 5 Speedotron power supplies are equipped with arc-protected outlets. However, as with any electrical equipment, arc-over (an electrical discharge between two physically dis- connected electrical terminals) is a possibility. When light cables, flash tubes or power cords are improperly seated, arc-over may occur.
6 7 OPERA TING INS TRUC TIONS Operation of the D604, D1204 and D1604 power supplies is simple and straight for- ward. This sequence of operation is suggested for maximum life and dependability. Make sure that the Model and Power switches are in the off position and the Push to Reset button is fully depressed into its socket.
8 9 One light: Symmetrical mode in any outlet, will receive 600Ws. Asymmetrical mode in outlets 1 or 2, will receive 600Ws; when using outlets 3 or 4 output is 450Ws. Two lights: Symmetrical mode, all outlets share an equal amount of power. Two lights each receive 300Ws (600Ws divided by 2).
10 11 One light: Symmetrical mode in any outlet will, receive 1600Ws. Asymmetrical mode in outlets 1 or 2, will receive 1600Ws; when using outlets 3 or 4 output is 1200Ws. Two lights: Symmetrical mode, all outlets share an equal amount of power. Two lights each receive 800Ws (1600Ws divided by 2).
12 13 D1204 Power Supply Maximum power: . . . . . . . . . . . . . . . . . . . . .1200Ws Number of light unit outlets: . . . . . . . . . . . .4 Recycle time: watt-seconds seconds (to 85% voltage, ANSI standard) 1200 4.1 600 2.0 300 1.0 Flash duration : .
14 15 *New MW9H flashtubes supplied with M11 light units handle up to 1200Ws. The MW9M flashtubes have a maximum capacity of 1000Ws. OPERA TING INS TRUC TIONS Operation of Brown Line power supplies is simple and straight forward. It is suggest- ed that this sequence of operation be utilized for maximum life and dependability.
16 17 One light: Symmetrical mode in any outlet, will receive 800Ws. Asymmetrical mode in outlets 1 or 2, will receive 800Ws; when using outlets 3 or 4 output is 600Ws. Two lights: Symmetrical mode, all outlets share an equal amount of power. Two lights each receive 400Ws (800Ws divided by 2).
18 19 DESCRIPTION OF C ONTROL S Power – turns power supply on and off. (Flashes light units when turning off.) Model – turns model lamps on and off. Symmetrical/Asymmetrical – controls power distribution. In the symmetrical position, power is split equally between all lights.
20 21 200 100 50 150 TE CHNICAL SPE CIFICA TIONS D202 Power Supply Maximum power: . . . . . . . . . . . . . . . . . . . . .200Ws Number of light unit outlets: . . . . . . . . . . . .2 Recycle time: watt-seconds seconds (to 85% voltage, ANSI standard) 200 3.
22 23 To connect light units, align the light unit plug with the power supply outlet and apply even pressure while pushing. Black colored light unit connectors are of the “ quick release ” type that only require pushing the connector firmly until it is fully seated.
24 25 T echnical Specifications Maximum power: MW3 (for MW3R, MW3U, M90) . . . . . . . . . . . . . .400Ws MW3C (for MW3R/CC, MW3U/CC, M90/CC) . . .400Ws MW3Q (for MW3UQ, M90Q) . . . . . . . . . . . . . . . .1200Ws MW3QC (for MW3UQ/CC, M90Q/CC) . . . .
26 27 UNIVERSAL LIGHT UNIT S (REMO V ABLE REFLE CT ORS) M11, M11/CC, M11Q and M11Q/CC The M11 series universal light units share a common base, but are differentiated by the type of flash tube each contains.
28 29 TROUBLE-SHOO TING System will not work at all; no flash. Check that sync cable, AC power cord and light unit cables are firmly and properly attached.
30 31 Ws per flash tube MW3-1 MW3Q MW9H MW9Q 100Ws 1/1500 1/1500 1/3000 1/3000 200Ws 1/1200 1/1200 1/2200 1/2200 400Ws 1/750 1/750 1/1400 1/1400 600Ws - 1/580 1/1000 1/1000 800Ws - 1/450 1/700 1/700 1.
© 1997 Speedotron Corporation SPEEDO TRON’S LIMITED W A RRANTY Speedotron guarantees to repair or replace, free of charge, any part or parts (except for flash tubes and modeling lamps) found by factory inspection to be defective due to faulty material or workman- ship, provided the equipment is returned to our factory prepaid.
An important point after buying a device Speedotron Brown Line Equipment (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Speedotron Brown Line Equipment yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Speedotron Brown Line Equipment - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Speedotron Brown Line Equipment you will learn all the available features of the product, as well as information on its operation. The information that you get Speedotron Brown Line Equipment will certainly help you make a decision on the purchase.
If you already are a holder of Speedotron Brown Line Equipment, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Speedotron Brown Line Equipment.
However, one of the most important roles played by the user manual is to help in solving problems with Speedotron Brown Line Equipment. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Speedotron Brown Line Equipment along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center