Printed in USA 12/04 P/N 118000 rev . A Models included: • GEO • EDGE.
2 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 W ARNING . . . Not T o Be Used for Per sonnel Protect ion Never use this produc t as a sensing device for person nel protection.
P/N 118000 rev . A 3 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Introducing PresencePLUS P4 The PresencePLUS P4 (or the Sensor) is an easy-to-use vision sensor with advanced visual inspection capabilities.
4 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 components/ connections components/ connections Cable Connections 1. If a light will be powered by the Sensor , connect it to the 3-pin Light connector .
P/N 118000 rev . A 5 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Light Connector (Banner lights only) 1 = Brown 24V 2 = n/a 3 = Blue (ground).
6 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 sensor configuration sensor configuration T ypical IP Address: 192.168.0.2 step 3 step 3 PC Configuration 1. Ethernet communication, configure the IP address of your computer .
P/N 118000 rev . A 7 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 sensor startup sensor startup step 5 step 5 Launching Software 1. Start the PresencePLUS program by clicking Start > Program Files > PresencePLUS .
8 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Software Setup Use the Main Menu toolbar to navigate the PresencePLUS P4 options. Proceeding from left to right, the buttons in the Menu toolbar step through the process of creating an inspection file.
P/N 118000 rev . A 9 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 T ool Options NOTE: T ool availability depends on P4 model. creating inspections creating inspections This screen automatically configures the parameters chosen in the T ools screen.
10 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 running inspections running inspections Viewing Results Display Options Select an inspection to run, and view the results of the inspection.
P/N 118000 rev . A 11 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 sensor configuration sensor configuration step 7 step 7 System Setup Use th.
12 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Maintenance Maintenance tasks include keeping the hardware free of dust and dirt and updating the PresencePLUS software as new versions become available.
P/N 118000 rev . A 13 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 sensor t roubleshooting sensor t roubleshooting T roubleshooting Problem Cause/Solution • Error Code is displayed on PC.
14 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Specifications Models Right-Angle In-Line GEO: P4GR EDGE: P4ER GEO: P4GI EDGE: P4EI Part Numbers GEO: 71431 EDGE: 73599 GEO: 71432 EDGE: 73600 Dimensions * Measured length does not include connectors or cables H x W x L: 55.
P/N 118000 rev . A 15 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Memory Stores up to 12 inspection files Power Voltage: 10-30V dc Current: 500 mA max. Acquisition 500 frames per second max. Image size: 126 x 98 pixels Levels of Gray Scale: 256 Imager 2.
Ba nn er En gi ne eri ng Co rp ., 97 14 T en th Av e. No . Mi nn ea po li s, MN 5 54 41 Ph on e: 7 63 .5 44. 31 64 ww w .b an ne re ng in ee rin g. co m Em ai l: se ns or s@b an ne re ng in ee rin g.
An important point after buying a device Banner American Products EDGE (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Banner American Products EDGE yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Banner American Products EDGE - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Banner American Products EDGE you will learn all the available features of the product, as well as information on its operation. The information that you get Banner American Products EDGE will certainly help you make a decision on the purchase.
If you already are a holder of Banner American Products EDGE, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Banner American Products EDGE.
However, one of the most important roles played by the user manual is to help in solving problems with Banner American Products EDGE. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Banner American Products EDGE along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center