Instruction/ maintenance manual of the product UL633-1 Spectra
Go to page of 31
G L 4 0 0 S e r i e s www .trimble.com T rimble Construction Division 5475 Kellenburger Road Dayton, Ohio 45424 USA +1-937-245-5600 Phone www .trimble.
G L 4 0 0 S e r i e s www .trimble.com T rimble Construction Division 5475 Kellenburger Road Dayton, Ohio 45424 USA +1-937-245-5600 Phone www .trimble.
Printed in Germany Q104735 Rev . A(01/12) Ser vice and Customer Advice North-Latin America T rimble Spectra Precision Division 8261 State Route 235 Dayton, Ohio 45424 U.S.A. +1 (888) 272-2433 (T oll Free in U.S.A.) +1-937-482-0030 Fax www .trimble.com www .
Printed in Germany Q104735 Rev . A(01/12) Ser vice and Customer Advice North-Latin America T rimble Spectra Precision Division 8261 State Route 235 Dayton, Ohio 45424 U.S.A. +1 (888) 272-2433 (T oll Free in U.S.A.) +1-937-482-0030 Fax www .trimble.com www .
Printed in Germany Q104735 Rev . A(01/12) Ser vice and Customer Advice North-Latin America T rimble Spectra Precision Division 8261 State Route 235 Dayton, Ohio 45424 U.S.A. +1 (888) 272-2433 (T oll Free in U.S.A.) +1-937-482-0030 Fax www .trimble.com www .
1 T ABLE OF CONTENTS Introduction 2 FOR YOUR SAFETY 2 COMPONENTS 2 How to use the Laser System 3 Powering the Laser 3 RC603 Radio/IR Remote Control 3 T urning On/Off the RC603 3 LASER SETUP 4 T urning.
2 Introduction Thank you for choosing one of the Spectra Precision Lasers from the T rimble family of precision lasers. The universal laser is an easy-to-use tool that offers accurate horizontal, vertical and sloped laser reference up to 1300 ft (400 m) away using a receiver .
3 HOW TO USE THE LASER SYSTEM POWERING THE LASER Batteries W ARNING Ni-MHbatteries maycontain smallamounts ofharmful substances.Be sure tocharge thebattery before using it for the rst time, and after not using it for an extended length of time.
4 LASER SETUP Position the laser horizontally (tripod mount and rubber feet downward!) on a stable platform, wall mount or tripod at the desired elevation. The laser recognizes automatically whether it is used horizontally or vertically when switched on.
5 Standard Features X-Y -Z-grade entering – Step and Go mode Quickly press and release button 2 startsthegradeenteringmode.Bothgradevalueswillbeshown.
6 Usebutton 1 or 2 (PlusorMinus)tosetthedesireddigit. Thelaserwillself-leveltotherequiredgradepositionafterconrmingthegradechangewithbutton 4 .
7 Special MENU Features Menu Functions (Radio controlled) Press and release button 1 attheStandardDisplaytoentertheMENU. The menu offers always only the features which can be selected depending on the setup (horizontal or vertical).
8 Automatic PlaneLok mode The PlaneLok mode can be activated in horizontal and vertical automatic and manual mode. In PlaneLok mode when set up horizontal, the beam will .
9 2. Attach the HL750 receiver to a grade rod. Check the laser ’s elevation next to the laser then position the receiveratthesecondpointWITHOUTchangingthereceiver’selevationontherod.
10 4.PressandreleasetheMENUbuttonattheStandardDisplayandselect AxisAlign. 5.Selectthedesiredaxisthenpressbutton 4 tostart AxisAlign.
11 Start Reference Check Before starting some grade work which is very sensitive an additional Reference Check can be started manually . Press and release the MENU button at the Standard Display and select ReferenceCheck.
12 The RC603 Service menu offers additional features: RF IR options Press and release button 4 toconrmtheselectionandselectoneofthefollowingoptions: RF On; IR auto => Radio on all times; IR will be activated automatically after radio connection has been lost.
13 Z-axis Automatic Spot Lok Automatic SpotLok (like PlaneLok) can be used to align and hold the plumb beam automatically to the SF601’s centerpointandcontinuouslyadjustingtheZ-andX-axis untilexitingthismode.
14 Line Scan Line Scan centers the rotor horizontally and can be used to align the plumb beam to a desired horizontalposition.Press andreleasethe MENUbuttonat theStandard Displayandselect Line Scan.
15 Pairing the transmitter with remote control The chain symbol at button 1 indicates the remote has never been paired before which means no radio connectivity is given. Pressing the pairing button 1 will initiatea pairing request.Thetransmitter has tobe in pairing mode as shown above.
16 Grade Entry SelecttheGradeEntryiconandpressandreleasebutton 4 toopentheGradeEntrymenu. Buttons 6/7 canbeusedtotogglebetweenStepandGoandDigitSelect. Press and release button 4 toconrmtheselection.
17 User Name Select the User name icon and press and release button 4 to open the User name menu. One row for typing names in big font (15) and one row in small font (18) for letters or numbers are available.
18 CALIBRA TION Checking Calibration of the Y - and X-Axes 1. Set up the laser 30 m (100 ft) from a wall and allow it to level. 2. Set the grade to 0.000% in both axes. 3. Raise/lower the receiver until you get an on-grade reading for the +Y axis. Using the on-grade marking notch as a reference, make a mark on the wall.
19 T roubleshooting Any errormessage canbe deleted with ashort pressof button 4 (OK). The table shows the related description andpossiblesolutions.Thenextservicecentershouldbe contactedifadifferenterrormessageasshownat the table will be displayed.
20 SF601 - User Guide SF601attachedtoagraderod using the standard receiver clamp Components SF601 SF601attachedtothe optional pipe laser target base 1. SF601 2. Slider 3. CenterHole 4. PowerButton 5. BubbleVial 6.
21 Powering the SF601 1. Open the battery door pulling the battery door latch. TheSF601willbeshippedwithalkalinebatteries. Rechargeablebatteriescanbeusedoptionalbutneedtobechargedexternally 2.
22 Using SpotLok mode (like PlaneLok) aligns and holds the plumb beam automaticallytotheSF601centerpoint(bothaxes)untilexitingthismode.
23 PROTECTING THE UNIT Do not expose the unit to extreme temperatures or temperature changes (do not leave inside the car). The unit is very robust and can resist damage if dropped even from tripod height.
24 TECHNICAL DA T A UL633 Leveling accuracy 1,3 : ±0.5mm/10m,1/16“@100ft,10arcseconds Grade accuracy 1,3 : ±1.
G L 4 0 0 S e r i e s www .trimble.com T rimble Construction Division 5475 Kellenburger Road Dayton, Ohio 45424 USA +1-937-245-5600 Phone www .trimble.
25 DECLARA TION OF CONFORMITY Please disregard the declaration of conformity within the manual. Following is the valid declaration: We T rimble Kaiserslautern GmbH Declareunderoursolerespo.
An important point after buying a device Spectra UL633-1 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Spectra UL633-1 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Spectra UL633-1 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Spectra UL633-1 you will learn all the available features of the product, as well as information on its operation. The information that you get Spectra UL633-1 will certainly help you make a decision on the purchase.
If you already are a holder of Spectra UL633-1, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Spectra UL633-1.
However, one of the most important roles played by the user manual is to help in solving problems with Spectra UL633-1. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Spectra UL633-1 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center