SPECO TECHNOLOGIES KEYBOARD CONTROLLER KBD-927 Instruction Manual L Please read this manual thoroughly before use and keep it handy for future reference.
2 WARNING AND CAUTION TO REDU CE TH E RISK O F F IRE OR ELECT RIC SHOCK, DO NOT EXP OSE THI S PRO DUC T TO RAIN OR MOISTURE. DO NOT INSERT ANY MET ALLI C OBJECTS T HROUGH THE VENTILA TION GRILL S OR OTHER OPENING S ON THE EQUI PMENT .
3 FCC COMPLIANCE STATEMENT FCC INFORMATION: THIS E QUIPMENT HAS BEEN TESTED AND F OUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PU RSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVI DE REASONABLE PROTECTION A GAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMEN T.
4 IMPORTANT SAFEGUARDS 1. 2. 3. 4. 5. 6. 6A . 7. 8. 9. 10 . 11 . 12 . 13 . 14 . 15 . 16 . 17 . 18 . 19 . READ I NSTRUCTI ONS -- All the safet y and o perat in g in s t ru cti ons shou ld be rea d befor e the ap plia nce is oper ate d.
5 Table of Contents Chapter 1.0 INTRODUCTION 1.1 Features 1.2 Unpacking Chapter 2.0 INSTALLATION 2.1 Connection Diagram 2.2 Dip Switch Setting 2.3 Keyboard Setup 2.4 Install with ADR series 2.5 Install with SDR series 2.6 Install with IDR series Chapter 3.
6 Chapter 1 INTRODUCITON 1.1 Features This keyboard controller is capable to control 32 Fast raxII dome cameras and remote control functions for variety of external switching devices like Multip lexer.
7 1.2 Unpacking Unpack the equipment and make sure all listed items are included in the box. Contents of Keyboard box Keyboard contro ller ------------------------------- 1 Junction box --------------.
8 Chapter 2 INSTALLATION 2.1 Connection Diagram 2.1.1 Basic Installation Diagram 3~4 5~8 1~2 1~4 ALARM OUTPUT UP TO 4 ALARM OUTPUT ALARM OUTPUT ALARM INPUT HALF DUPLEX MODE : TX+,TX- RS-4 85 ALARM INP.
9 2.1.2 Single Multiplexer RS-485(-) PIN No.5 RS-485(+) PIN No.4 POWER AC 24V AL5 AL6 GND AL7 AL8 GND COM3 NC3 NO3 COM4 NC4 NO4 AL1 GND AL2 AL3 GND AL4 COM1 COM2 NO1 NC1 NO2 NC2 AC+ RX-(TX- ) RX+(TX+).
10 2.1.3 Single User with Two Multiplexer RS-485(+) PIN No.4 RS-485(-) PIN No .5 BNC SPOT MONITOR 2ND MAIN MONITOR 2ND MULTIPLEXER AWG # 24 BNC BNC 1ST MAIN MONI TOR 1ST MULTIPLEXER BNC AC 24V POWER P.
11 2.1.4 Two Multiplexer with Slave Keyboard Controller SPOT MONITOR SPOT MONITOR RS-485(-) PI N No.5 RS-485(+) PIN No .4 BNC 1ST MULTIPLEXER FOR SLAVE K/B 1ST MAIN MONI TOR BNC 2ND MULTIPLEX ER 2ND M.
12 2.2 Termination & Dip Switch Setting The first and last devices in an installation (dome and keyboard controller) must have the data line terminated by setting the DIP switch. Without proper termination, there is potential for control signal errors.
13 DOME Multi- plexer Sub- controll er Termination 1 2 3 4 5 6 Controller 7 8 ON ON ON ON SLAVE ON OFF OFF OFF OFF reserved MASTER OFF Factory Use Table 1 - S1 Sw itch Setting 2.3 Multiplexer Control Duplex setup: NOTE: Multiplexers require a new ROM version to be controlled by the keyboard controller.
14 Unit address: 001 ~ 128 Protocol: B1 2.4 Keyboard Setup User need to setup net work, passwords and sp ecial functions such as Uploading and Downloading programmed data from the dome cameras. To enter the Keyboard menu, press Ctrl + Menu . You will see the following menu.
15 - Com Ports Select the device to be connected on selected port. Dome : None/Dome … MUX : None/DUPLEX/TRIPLEX/AUX IN/AUX I/O… DVR485 : None/ADR/SDR/IDR/AUX IN/AUX I/O… DVR232 : None/ADR/SDR/ID.
16 ← Current Device ID = 1 ← Default setting is 9999 for administrator 1111 for user FASTRAX-2L Vxxx Slave ID = 1 Input Password : xxxx CAM:000 3. P ress Ctrl + Menu . Set the Slave ID to 01 4. Set Slave Node to “B” in case that master keyboard model is KBD-927(N : NTSC,P : PAL) ← A : KBD-927 Slave ID = 1 Slave Node : A/B 2.
17 A. Switch the keyboard controller ON B. Input password (Factory setting is 9999 ) C. Open the menu of the key board controller by pressing Ctrl + Main Key.
18 Select “Camera” on the Device menu. Unit ID should be 1 up to 99. Unit ID is not allowed number “0”. Set “PTZ Device” and “ID” of the dome camera.
19 RS232/RS485 Baud Rate Parity Data Stop Usage RS232 9600 None 8 1 Remote Control RS485 9600 None 8 1 PTZ Control 5) After setting Unit ID, Camera, and RS232/RS485, in stalling dome camera is basically completed. Please refer to the manual of A DR for the other installation.
20 D. Set as below in Network menu. Set Baud Rate Dome : 9600 Mux : 9600 DVR485 : 9600 DVR232 : 9600 Com Ports Dome : Dome Mux : None DVR485 : AUX IN DVR232 : SDR 4) How to setup SDR - Switch the SDR on. - Press the Menu button. Input password accordi ng to the instruction.
21 Select Camera of Device menu on the above menu. PTZ set up on the above Setup menu Select TEXT IN/PTZ after PTZ is installed, and then set-up as below RS232/TEXT IN Baud Rate Parity Data Stop Usage.
22 2.7 Install with IDR series 22 AWG UTP CABLE CONVERTER RS-232 CABLE DATA1 DATA2 DOME R(T)X- R(T)X+ WIRE CONNECTION JUNCTION BOX DOME1 + DOME1 - TX+(RS-485) TX-(RS- 485) DOME2 + DOME2 - IDR SERI ES .
23 - Switch the IDR on. If press setup button on the above scr een, the below screen will be appeared. Select camera input number that dome camera connected. Then install as below to select set-up PTZ after checking PTZ box. Port : COM2 RX Device : Fastrax….
24 If PTZ is not necessary for IDR, cable and installa tion here is not needed. (IDR is able to be controlled remotely and there’s no PTZ function) 8) How to IDR Remote setup - If selects Setup on main menu, the below screen will be appeared.
25 Chapter 3 OPERATION 3.1 Keyboard Lock/Unlock (Hidden command) When the user leaves the control desk, he may wish to lock the keyboard controller to prevent unauthorized use. Pressing 777 + Enter will lock the keyboard controller. Pressing 777 + Enter while the keyboard is locked will open the password screen.
26 Select cameras 1 to 16 by pressing the camera number and then Main. The selected camera will appear in the full screen mode and is under control if it was dome camera. Even if no camera is connected to the multiplexer input, the screen will show the camera input (see following example).
27 2) to the spot output of multiplexer 2 and the keyboard controller has control of the selected camera. 31+Cam = camera 15 of the second multiplexer.
28 Key operation example Ctrl + Menu : Press and hold down Ctrl Key and press Menu Key 1 + Cam : Press 1 Key, Cam Key sequentially Ctrl + Joystick : Press and hold down Ctrl Key while manipulate Joystick Handle Enter + Joystick : Press and hold down Enter Key while manipulate Joystick Handle 3.
29 Manual Focus Overrides auto focus. Moving the Zoom handle reactivates Auto Focus mode. Manual Iris Overrides auto iris. Moving the joystick reactivates Auto Iris mode. Zoom Zoom control. Joystick Twist Up / Dow n Left / Right Press(Toggle) Zoom control (proportional to pos ition).
30 3.3.3 Keys for DVR Function Key Label Descriptions Id Selection DVR ID Selection. (e.g.:1 or 2+DVR). PTZ Open a Pan/Tilt/Zoom screen which al lows yo u to control properly configured cameras. Play/Pause Play recorded data / Pause playing. Rewind Play video backward at high spee d.
31 X times Forw ard play No.+ Fast rewind at x( 1~8 ) times speed in IDR Shuttle ring CTRL+ENTR+ Joystick The Shuttle Ring only functio ns in the Playback mode. Turning the rin g clockwise plays video for ward. Turning the ring counterclock wise plays video backward.
32 Appendix A Trouble Shooting If problems occur, verify the installation of the camera with the instructions in this manual and with other operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the equipment manual for further information.
33 Appendix B SPECIFICATION Power Consumption Control Method Baud Rates Operating Temperature Humidity Storage temperature Dimension Weight Communication 12VDC, 0.5W RS-485, RS-232C 2400~230K bps 0°C to 50°C(32 o F to 122 o F) 0 to 90%RH(non-condensing) -20°C to 60°C(-40 o F to 122 o F) 380x168x70 Professional Joystick : 1.
An important point after buying a device Speco Technologies KBD-927 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Speco Technologies KBD-927 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Speco Technologies KBD-927 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Speco Technologies KBD-927 you will learn all the available features of the product, as well as information on its operation. The information that you get Speco Technologies KBD-927 will certainly help you make a decision on the purchase.
If you already are a holder of Speco Technologies KBD-927, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Speco Technologies KBD-927.
However, one of the most important roles played by the user manual is to help in solving problems with Speco Technologies KBD-927. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Speco Technologies KBD-927 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center