SWITCHER PROCESSOR PACK MVS8000SF-C INST ALLA TION MANUAL 1st Edition (Revised 2) HK-PSU04 MKS-8110HD MKS-8160HD MKS-8170HD MKS-8210HD MKS-8440HD MKS-8210K1 MVS-8000SF MULTI FORMAT SWITCHER PROCESSOR .
MVS-8000SF ! W ARNING This manual is intended for qualified service personnel only . T o reduce the risk of electric shock, fire or injury , do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
MVS-8000SF Attention-when the product is installed in Rack: 1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit.
.
1 MVS-8000SF Table of Contents Manual Structure Purpose of this manual .............................................................................................. 3 Related manuals ...................................................................
.
3 MVS-8000SF Purpose of this manual This manual is the installation manual of Switcher Processor Pack MVS8000SF-C and their optional boards and units. This manual is intended for use by trained system and service engineers, and describes the information on installing the MVS8000SF-C.
.
1-1 MVS-8000SF Section 1 Installation 1-1. Operating Environment Operating guaranteed temperature : + 5 d C to + 40 d C Performance guaranteed temperature : + 10 d C to + 35 d C Operating humidity : 10 % to 90 % (relative humidity) Storage temperature : _ 20 d C to + 60 d C Mass : Approx.
1-2 MVS-8000SF 1-3. Installation Space (External dimensions) Unit : mm 1-3. Installation Space (External dimensions) 1-3-1. MVS8000SF-C 35 7 520 375 61 370 144.
1-3 MVS-8000SF 1-4. Installing the Options The MVS8000SF-C is shipped from the factory with the necessary option boards (refer to the following table) already installed in accordance with the specified system configuration. The following options are available for the MVS-8000SF.
1-4 MVS-8000SF Installation Procedure 1. Turn off the main power of the MVS-8000SF and disconnect the AC power cord from the wall outlet. 2. Loosen the four screws (with drop-safe) and remove the front panel to the arrow. 3. Remove the six screws and remove the plug-in board loose-proof assembly.
1-5 MVS-8000SF Name of option Name of board Slot on the front side MKS-8210HD/SD/M * 1 DO-41/DO-42/ 3, 8 DO-44 board MIX-45 board 4, 9 KPC-16 board 5, 10 DI-40/DI-41/ 6, 11 DI-43 board MKS-8170HD/SD/M.
1-6 MVS-8000SF 1-4-2. Installing the Connector Board 1. Remove the two screws and remove the blank panel. n To install the connector board into the slot in which the other board is installed already, loosen the two fixing screws and remove the connector board that is installed already.
1-7 MVS-8000SF 1-4-3. Installing the HK-PSU04 The HK-PSU04 is used after it is installed in the MVS- 8000SF. n Before installing the HK-PSU04, be sure to turn off the main power. If the HK-PSU04 is installed while the main power is turned on, it can result in electrical shock or damage to printed circuit boards.
1-8 MVS-8000SF 1-4-5. Installing the MKS-8420M MKS-8420M consists of the following boards. . CC-90 board : 1 piece . CPU-DK module : 3 pieces CC-90 board installation Refer to “1-4-1. Installing the Plug-in Boards”. CPU-DK module installation Replace a CPU-DK module on the following boards with each CPU-DK module of MKS-8420M.
1-9 MVS-8000SF 1-5. Rack Mounting 1-5. Rack Mounting The MVS-8000SF is mounted in the 19-inch standard rack. To mount the MVS-8000SF in the rack, use the specified rack mount kit and follow the procedure described below.
1-10 MVS-8000SF 1-5. Rack Mounting 2. Loosen the screws on the rear of the right and left adapters and adjust the length of the adapter according to the depth of the rack. (The illustration below shows the left adapter.) n Maximum depth of adapter : 750 mm Minimum depth of adapter : 595 mm 3.
1-11 MVS-8000SF 1-6. Matching Connectors 1-6. Matching Connectors Use the following connectors, cables or equivalents when connecting cables to the unit.
1-12 MVS-8000SF _ EXT VIEW _ 1 5 6 9 1 13 14 25 EXT VIEW + V GPI OUT x B GPI OUT x A GPI OUT 5-8 GPI OUT COM x : 1-4 <Relay> <Open collector output> ( * 3) ( * 4) 1-7. Input/Output Signals of Connectors 1-7. Input/Output Signals of Connectors The input/output signals of the connectors at the rear panel are as follows.
1-13 MVS-8000SF _ EXT VIEW _ 1 5 6 9 1 8 _ EXT VIEW _ 1-7. Input/Output Signals of Connectors REMOTE 1 to 4 : RS-422A (D-sub 9-pin, Female) <DEVICE> ( * 5) from External Devices Pin No.
1-14 MVS-8000SF 1-8. Checks on Completion of Installation <LED> D101, D102, D103, D104 (A-4), ND101, ND102 (A-3) : MAIN CPU status LED Main CPU status indication. D309 (A-2) : RESET status LED System reset status indication. Lit when S301 is pressed or the power voltage drops to + 3.
1-15 MVS-8000SF D802 (A-2) : COM2 100 status LED COM CPU-2 Ethernet communication speed status indication. Lit : 100 Mb/s Not lit : 10 Mb/s D901 (A-2) : REF EXT status LED REF IN signal presence/absence status indication. Lit when the REF signal is input to the REF IN connector.
1-16 MVS-8000SF 1-8. Checks on Completion of Installation CN503 (A-5) : TERMINAL pin This pin is connected to the COM CPU-1 control terminal and used during maintenance. Conforms to RS-232C. CN703 (A-5) : TERMINAL pin This pin is connected to the COM CPU-2 control terminal and used during maintenance.
1-17 MVS-8000SF 1-8. Checks on Completion of Installation DI3 (F-3), DI6 (F-3), DI7 (F-3), DI8 (F-4) (green) : STATUS1 to STATUS4 LED Used for maintenance purpose. Only the STATUS1 LED is lit in normal operation. DI4 (green) (B-5) : + + + + + 3.3 V Indicates the status of the VCC (CORE) and VCC (I/O) powers that are supplied to the CPU-DK module.
1-18 MVS-8000SF 1-8. Checks on Completion of Installation 2. DO-41 board (MKS-8210HD)/DO-42 board (MKS-8210SD)/DO-44 board (MKS-8210M) AB C D E F G H J K L M N P R 1 2 3 4 5 6 7 8 9 10 11 12 13 D1 TP2.
1-19 MVS-8000SF 1-8. Checks on Completion of Installation . . . . . DO-41/42 board <LED> D1 (A-3) : + + + + + 12 V + 12 V power supply status indication. Lit when the + 12 V power is supplied. If this LED does not light, the fuse may have blown.
1-20 MVS-8000SF 1-8. Checks on Completion of Installation <TEST terminal> E1 (F-6), E2 (J-4), E3 (L-6), E4 (E-9), E5 (J-9), E-6 (M-12), E-7 (N-9), E-8 (A-9) : GND terminal (DO-41 board) Use this terminal as the earth point for measuring the respective check terminals.
1-21 MVS-8000SF 1-8. Checks on Completion of Installation . . . . . DO-44 board <LED> D1 (A-3) : + + + + + 12 V + 12 V power supply status indication. Lit when the + 12 V power is supplied. If this LED does not light, the fuse may have blown. D5 (A-4) : CONF ERR status LED FPGA (EP20K100E) CONFIG DONE status indication.
1-22 MVS-8000SF 1-8. Checks on Completion of Installation TP1 (A-3) : + + + + + 12 V check terminal + 12 V measuring terminal. TP4 (H-6), TP5 (H-13), TP9 (N-13) : CK (clock for video signal) signal check terminal Used when checking the clock for video signal.
1-23 MVS-8000SF 1-8. Checks on Completion of Installation AB C D E F G H J K L M N P R TP1801 TP3605 TP3610 TP3606 TP361 1 TP3607 TP3603 TP3601 TP3604 TP3602 1 2 3 4 5 6 7 8 9 10 11 12 13 D1 D2 D2201 .
1-24 MVS-8000SF 1-8. Checks on Completion of Installation D3701 (A-5) : + + + + + 2.5 V + 2.5 V power supply status indication. Lit when the + 2.5 V power is supplied. D3702 (A-4) : + + + + + 3.3 V + 3.3 V power supply status indication. Lit when the + 3.
1-25 MVS-8000SF 1-8. Checks on Completion of Installation D6108 D6107 D6106 D6105 D6104 D6103 D6102 D6101 D6100 D6109 AB C D E F G H J K L M N P R E6062 TP6800 TP6801 E6066 TP6000 E6069 TP6068 TP6060 .
1-26 MVS-8000SF 1-8. Checks on Completion of Installation D6103 (A-10) : WASH2 FPGA CONFIG DONE status LED WASH2 FPGA CONFIG DONE status indication. Not lit when configuration is completed. D6104 (A-9) : WASH1 FPGA CONFIG DONE status LED WASH1 FPGA CONFIG DONE status indication.
1-27 MVS-8000SF 1-8. Checks on Completion of Installation 5. DI-40 board (MKS-8210HD)/DI-41 board (MKS-8210SD)/DI-43 board (MKS-8210M) AB C D E F G H J K L M N P R 1 2 3 4 5 6 7 8 9 10 11 12 13 D1 D2 .
1-28 MVS-8000SF AB C D E F G H J K L M N P R 1 2 3 4 5 6 7 8 9 10 11 12 13 D1 D2 D3 TP2 E1 TP1 TP3 D5 D6 E5 E3 E2 E4 E6 S1 CN1 TP201 TP202 TP203 TP204 E7 TP1000 TP2000 TP3000 TP3500 TP4000 TP4500 TP50.
1-29 MVS-8000SF 1-8. Checks on Completion of Installation E1 (A-4), E2 (J-2), E3 (F-6), E4 (D-11), E5 (H-11), E6 (N-8), E7 (L-12) : GND terminal (DI-41 board) Use this terminal as the earth point for measuring the respective check terminals. TP1 (A-4) : + + + + + 3.
1-30 MVS-8000SF AB C D E F G H J K L M N P R TP1 D1 TP9501 D9551 D9051 TP9001 E1 S101 S1 E6 E7 D401 CN101 TP3001 TP3501 TP8001 TP4001 TP4501 TP5001 TP5501 E3 E2 TP2501 TP2001 TP1001 TP1501 TP7001 TP7501 TP6501 TP6001 1 2 3 4 5 6 7 8 9 10 11 12 13 DI-43 board A side/Component side .
1-31 MVS-8000SF 1-8. Checks on Completion of Installation TP1 (A-3) : + + + + + 12 V check terminal + 12 V measuring terminal. TP501 (P-13) : HD (horizontal sync) signal check terminal HD signal measuring terminal.
1-32 MVS-8000SF 1-8. Checks on Completion of Installation 6. DIF-119 board (MKS-8170HD)/DIF-122 board (MKS-8170SD)/DIF-141 board (MKS-8170M) AB C D E F G H J K L M N P R D2800 D3100 D2700 D2703 D2702 .
1-33 MVS-8000SF DIF-122 board A side/Component side AB C D E F G H J K L M N P R D2800 D3100 D2700 D2703 D2702 D2701 1 2 3 4 5 6 7 8 9 10 11 12 13 D3404 TP3401 TP3402 S2300 S2301 CN2301 CN2700 E2300 E.
1-34 MVS-8000SF 1-8. Checks on Completion of Installation TP1304 (G-12) : CRC signal check terminal (DIF- 119 board) CRC signal measuring terminal. TP1305 (G-12) : SIGDET signal check terminal (DIF-119 board) SIGDET signal measuring terminal. TP1500 (J-11) : RCLK signal check terminal (DIF- 119 board) RCLK signal measuring terminal.
1-35 MVS-8000SF 1-8. Checks on Completion of Installation TP3308 (L-12) : CK (clock for video signal) signal (DIF-119 board) Uses this terminal when checking the clock signal for video. TP3309 (H-5) : CK2 signal check terminal (DIF-119 board) Uses this terminal when checking the clock signal for video.
1-36 MVS-8000SF . . . . . DIF-141 board <LED> D2700 (A-7) : CONF ERR status LED FPGA (EP20K100E and Spartan II) CONFIG DONE status indication. Not lit when all configurations are completed. D2701 (B-7), D2702 (B-6), D2703 (B-6) : MAIN CPU status LED Main CPU status indication.
1-37 MVS-8000SF TP3309 (H-5) : CK2 signal check terminal Uses this terminal when checking the clock signal for video. TP3310 (G-11) : CK3 signal check terminal Uses this terminal when checking the clock signal for video. TP3400 (A-5) : + + + + + 1.8 V check terminal + 1.
1-38 MVS-8000SF 1-8. Checks on Completion of Installation 7. XPT-21 board (MVS-8000SF) E9 E7 AB C D E F G H J K L M N P R 1 2 3 4 5 6 7 8 9 10 11 12 13 D3401 S3401 CN3001 CN3301 E3 TP3001 E4 TP3005 TP.
1-39 MVS-8000SF 1-8. Checks on Completion of Installation CN3303 (A-6) : DEBUG terminal Not used. This terminal conforms to RS-232C. CN3901 (A-11) : IEEE1394 terminal Not used.
1-40 MVS-8000SF 1-8. Checks on Completion of Installation 8. OUT-23 board (MKS-8160HD)/OUT-24 board (MKS-8160SD)/OUT-27 board (MKS-8160M) AB C D E F G H J K L M N P R 1 2 3 4 5 6 7 8 9 10 11 12 13 D10.
1-41 MVS-8000SF . . . . . OUT-23/24 board <LED> D100 (A-3) : + + + + + 12 V + 12 V power supply status indication. Lit when the + 12 V power is supplied. If this LED does not light, the fuse may have blown. D104 (A-3) : + + + + + 5 V (OUT-23 board) + 5 V power supply status indication.
1-42 MVS-8000SF <Switch> S100 (A-3) : OUT-CPU RESET switch Pressing this switch initializes the CPU on the OUT-23/24 board. S1501 (A-7) : MONITOR reset switch The reset switch that is used to reset the monitor during maintenance through the terminal.
1-43 MVS-8000SF 1-8. Checks on Completion of Installation TP604 (N-12), TP1004 (N-5) : CRC signal check terminal (OUT-23 board) CRC signal measuring terminal. TP605 (N-11), TP1005 (N-5) : SIG_DET signal check terminal (OUT-23 board) SIG_DET signal measuring terminal.
1-44 MVS-8000SF . . . . . OUT-27 board <LED> D1 (A-3) : + + + + + 12 V + 12 V power supply status indication. Lit when the + 12 V power is supplied. If this LED does not light, the fuse may have blown. D700, D701, D702 (A-8) : OUT-CPU status LED OUT-27 board CPU status indication.
1-45 MVS-8000SF <Connector> CN1600 (A-5) : ISP common connector Used only for production in the assembly factory. Used for program writing into the JTAG device with ISP. CN1902 (A-7) : TERMINAL pin This pin is connected to the control terminal and used during maintenance.
1-46 MVS-8000SF 1-8. Checks on Completion of Installation 9. DIO-62 board (MKS-8440HD)/DIO-63 board (MKS-8440SD)/DIO-74 board (MKS-8440M) AB C D E F G H J K L M N P R 1 2 3 4 5 6 7 8 9 10 11 12 13 TP1.
1-47 MVS-8000SF . . . . . DIO-62/63 board <LED> D1 (A-3) : + + + + + 12 V + 12 V power supply status indication. Lit when the + 12 V power is supplied. If this LED does not light, the fuse may have blown. D5 (A-3) : + + + + + 5 V (DIO-62 board) + 5 V power supply status indication.
1-48 MVS-8000SF 1-8. Checks on Completion of Installation <TEST terminal> E1 (N-3), E2 (P-6), E3 (P-11), E4 (H-6), E5 (F-3), E6 (A-8), E7 (E-12) : GND terminal (DIO-62 board) Use this terminal as the earth point for measuring the respective check terminals.
1-49 MVS-8000SF 1-8. Checks on Completion of Installation TP2000 (H-2), TP2500 (K-2), TP3000 (L-3), TP3500 (N-3), TP4000 (L-3), TP4500 (K-8), TP5000 (L-8), TP5500 (N-8) : PLL_LOCK signal check terminal (DIO-62 board) PLL_LOCK signal measuring terminal.
1-50 MVS-8000SF . . . . . DIO-74 board <LED> D1 (A-3) : + + + + + 12 V + 12 V power supply status indication. Lit when the + 12 V power is supplied. If this LED does not light, the fuse may have blown. D2 (A-4) : + + + + + 1.8 V + 1.8 V power supply status indication.
1-51 MVS-8000SF <TEST terminal> E1 (N-2), E2 (P-6), E3 (P-10), E4 (H-6), E5 (F-3), E6 (A-5), E7 (C-12) : GND terminal Use this terminal as the earth point for measuring the respective check terminals. TP1 (A-3) : + + + + + 12 V check terminal + 12 V measuring terminal.
1-52 MVS-8000SF 1-8. Checks on Completion of Installation <LED> D1, D2, D3 (A-6) : MY-CPU status LED Status indication of the CPU on the MY-102 board. D201 (A-5) : + + + + + 12 V + 12 V power supply status indication. Lit when the + 12 V power is supplied.
1-53 MVS-8000SF 1-8. Checks on Completion of Installation <TEST terminal> E121 (P-8), E122 (P-10), E123 (P-3), E124 (P-4), E129 (P-11), E130 (P-9), E131 (P-4), E132 (P-5), E508 (E-12), E601 (D-7), E801 (N-7), E1001 (N-12) : GND terminal Use this terminal as the earth point for measuring the respective check terminals.
1-54 MVS-8000SF 11. CC-90 board (MKS-8420M) G F E D C B A 654321 D12 D18 D19 D10 D13 D14 D15 D16 D17 SW2 SW1 CPU-DR Module 1 ABC DEFG H J K LM NP R 2 3 4 5 6 7 8 9 10 11 12 13 E105 E108 E103 E106 E107.
1-55 MVS-8000SF 1-8. Checks on Completion of Installation TP401 (C-7) : CPU half clock signal check terminal Use this terminal to check the CPU half clock signal. TP402 (B-7) : CPU clock signal check terminal Use this terminal to check the CPU clock signal.
1-56 MVS-8000SF 12. CNI-9 board (Suffix : -12) (MKS-8110HD) CNI-9 board A side/Component side <Switch> S101 (A-3), S201, S301 (B-3), S401, S501 (C-3), S601 (D-3), S701, S801 (E-3), S901 (F-3), S.
1-57 MVS-8000SF 1-8-2. Checks on the Switch Setting the Number of Power Supply Units Before turning on the power of the MVS-8000SF, confirm that the switch S303 on the CA-44 board is set in the following position (default setting).
1-58 MVS-8000SF * a * a * b * b * b * b DATA LAN CTRL EDITOR PERIPH CTRL REMOTE DATA DATA CTRL REMOTE 1 PERIPH VTR DDR Switcher Processor Pack MVS8000SF-C Reference video signal Reference video signal.
1-59 MVS-8000SF 1-9. System Connection * a : For the AC power cord, refer to “Optional Items” of the “DME Processor Pack MVE-8000” Operation Manual. * b : For the AC power cord, refer to “Optional Items” of the “Multi-Format Switcher Processor MVS-8000” Operation Manual (15 page).
.
2-1 MVS-8000SF Section 2 Service Overview 2-1. Troubleshooting The main power of the MVS-8000 cannot be turned on. (Indicator does not light green.) The monitor picture is not displayed correctly. The main power of the MVS-8000SF cannot be turned on. (Indicator does not light green.
2-2 MVS-8000SF 2. Fan MVS-8000SF is air-cooled by the fans (on both sides). If dust has accumulated in the intake of the fan, air is prevented from flowing smoothly and this may result in a temperature rise inside the machine. This may have an adverse effect on performance and the life of the machine.
MVS-8000SF The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or.
Printed in Japan Sony Corporation 2003. 3 16 B&P Company ©2002 MVS8000SF-C (SY) E 3-620-565-03.
An important point after buying a device Sony MVS8000SF-C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sony MVS8000SF-C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sony MVS8000SF-C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sony MVS8000SF-C you will learn all the available features of the product, as well as information on its operation. The information that you get Sony MVS8000SF-C will certainly help you make a decision on the purchase.
If you already are a holder of Sony MVS8000SF-C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sony MVS8000SF-C.
However, one of the most important roles played by the user manual is to help in solving problems with Sony MVS8000SF-C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sony MVS8000SF-C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center