Instruction/ maintenance manual of the product OXOR II 19-7037 Bacharach
Go to page of 10
OXOR II INSTRUCTION 19-9126 Portable Oxygen Analyzer Part No. 19-7037 & 19-7044 Rev. 6 – October 1999 ® Bacharach, Inc. 621 Hunt Valley Circle, New Kensington, PA 15068 PH: 724-334-5000 • FAX: 724-334-5001 • Web: www.bacharach-inc.com E-mail: help@bacharach-inc.
WARRANTY Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in material and manufacture and will conform substantially to Bacharach Inc.
1 WARNING! Because this instrument is used to detect and monitor materials and conditions which are listed by OSHA or others as potentially hazardous to personnel and property, the information in this.
2 Figure 2. Battery Installation To prepare the instrument for operation, you must install four “C” size batteries, and (if desired) install the hose and probe as described in the following paragraphs.
If batteries are accidently installed in the wrong polarity, a positive temperature coefficient (PTC) thermistor will protect the instrument’s electronic circuitry. The instrument will operate once batteries are properly installed and the PTC thermistor is allowed to cool.
4 4 OPERATION To operate the Oxor II, you simply . . . • Set its POWER switch to ON, • Wait for the instrument to warm up (approx. 1 minute), • Span the display (if necessary), • Take a gas sample. Detailed operating procedures are presented below: 4.
5 4.6 Interpreting the Display Gas Display The LCD directly shows O 2 levels in the range from 0 to 25%. The display on the right indicates a O 2 level of 20.9%. 4.4 Using the Strap The instrument's elastic strap allows the unit to be either hand-held, or hung on nearby objects.
6 Low Battery Indications When the battery voltage becomes low, the “LO BAT” indicator appears. Although the instrument will continue to operate and give percent O 2 read- ings under these conditions, the batteries should be replaced as soon as possible.
6 PARTS/SERVICE 6.1 Parts List Item Part No. Battery Cover 19-3029 Basic Probe/Hose Assy. 19-3086 Optional Probe/hose Assy. 19-3076 6.2 Bacharach Sales/Service Centers 7 United States Bacharach, Inc. 621 Hunt Valley Circle New Kensington, PA 15068 Phone: 724-334-5051 Fax: 724-334-5723 E-mail: help@bacharach-inc.
Notes: 8.
An important point after buying a device Bacharach OXOR II 19-7037 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bacharach OXOR II 19-7037 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bacharach OXOR II 19-7037 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bacharach OXOR II 19-7037 you will learn all the available features of the product, as well as information on its operation. The information that you get Bacharach OXOR II 19-7037 will certainly help you make a decision on the purchase.
If you already are a holder of Bacharach OXOR II 19-7037, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bacharach OXOR II 19-7037.
However, one of the most important roles played by the user manual is to help in solving problems with Bacharach OXOR II 19-7037. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bacharach OXOR II 19-7037 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center