Instruction/ maintenance manual of the product 232SS21600 B&B Electronics
Go to page of 26
232SS21600 Manual Cover Page B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Ottawa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Smart Switch Model 232SS2 Docum ent N o. 232SS21600 This product Designed and Manuf ac tured of domestic and imported parts by International Headqua rters B&B Electron ics Mfg.
B&B Elect roni cs RESERVED. No par t of th i s publi cation may be reproduced or transm itted in any form or by any means, electronic or m echanical , includi ng photography, recording, or any information storage and retrieval system w ithout written consent.
232SS21600 Manual Table of Contents i B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 TA BLE OF CONTENTS Chapter 1: INTRODUCT ION ..............................................
232SS21600Manual 1 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Chapter 1: INTRODUCTION The RS-232 Four Por t Smart Switch/Port Combiner , Model 232SS2, allows one RS-232 host dev ice to connect to as many as four RS-232 devic es.
232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 2 Checklist Examine the shipping ca rton and contents for phy sical damage. If damage is found, file a claim with the shipper immediately.
232SS21600Manual 3 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Chapter 2: SETUP The 232SS2 is set up using an eight-pos ition dipswitch.
232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 4 Port Configuration In order to determ ine the proper port c onfiguration of the 232SS2, it is necess ary to have a basic understanding of the ter ms DCE and DTE.
232SS21600Manual 5 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 The 232SS2 supports the following RS-232 signals: TD, RD, SG , RTS, CTS, DSR, DCD, and DTR. The Smart Switch s elects port A as the default port at power up.
232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 6 Switch position 8 se lects the port c onfiguration, see sec tion titled "Port Configuration". Refer to Table 1.
232SS21600Manual 7 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Programming the Second Character The s econd character com es program m ed as the ASCII ST X character (decim al 2).
232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 8 Smart Sw itch/Port Combiner Mode This mode allow Ports A-D to select the m aster port using a handshak e line.
232SS21600Manual 9 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 A ty pical applic ation would be to have RTS and CT S tied together on the mas ter port.
232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 10 Table 3 - Timer Values The Set T imer Mode com mand r equires the third byte to be an ASCII “ M ” .
232SS21600Manual 11 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 The “ M ” tells the 232SS2 it is the set tim er m ode com m and and the “ 1 ” indicates to set up the tim er to ignor e switching com m ands.
12 232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Chapter 3: SOFTWA RE Introduction The 232M`SS2 c om es with two application program s that can be used to switch between ports.
232SS21600 Manual 13 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 To Uninstall SSwi tch.
14 232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Enter Port Addres s [02F8]: Enter Baud Rate ( 1 = 150 2 .
232SS21600 Manual 15 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 If the sof tware was installed in the default dir ectory: • At the DOS prom pt Type C: and press the ENT ER key .
16 232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 The Hot Key is a sequence of thr ee keys that mus t be pressed sim ultaneously to switch from one Smar t Switch Port to another.
232SS21600 Manual 17 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Hot Key Method This method enables the user to selec t any Sm art Switch port by pressing a predef ined sequence of keys at the sam e tim e after the SSTSR is installed (ref er to Progr am Ins tallation).
232SS21600 Manual Appendix A A-1 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 A PPENDIX A : ASCII C haracter Codes DECIMAL.
232SS21600 Manual Appendix C C-1 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 A PPENDIX B: Cable Cha rts All charts will indicate if the Master Por t of the 232SS2 should be configur ed as a DCE port or a DT E port.
C-2 Appendix C 232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Chart 3.
232SS21600 Manual Appendix C C-3 B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Chart 5.
C-4 Appendix C 232SS21600 Manual B&B Electro nics Mfg Co In c – 707 Dayton Rd - PO Box 1040 - Otta wa I L 61350 - P h 815-433-5100 - Fax 815-433-5104 Chart 7.
FCC Class A Equipm ent Stat em ent FEDERA L COMM UNICA TIONS CO MMI SSION RA DIO FREQ UENCY INTERFA CE STA TEMENT Class A Equipm ent This equipment has been tested and found to com ply with the limits for Clas s A digital device, purs uant to Part 15 of the F CC Rules.
An important point after buying a device B&B Electronics 232SS21600 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought B&B Electronics 232SS21600 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data B&B Electronics 232SS21600 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, B&B Electronics 232SS21600 you will learn all the available features of the product, as well as information on its operation. The information that you get B&B Electronics 232SS21600 will certainly help you make a decision on the purchase.
If you already are a holder of B&B Electronics 232SS21600, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime B&B Electronics 232SS21600.
However, one of the most important roles played by the user manual is to help in solving problems with B&B Electronics 232SS21600. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device B&B Electronics 232SS21600 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center