Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-22-ID / KFHHP-22-OD Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference . Indoor Unit .
TABLE OF CONTENTS OPERATION AND MAINTENANCE…………..………..…………………………………….....1-12 Instructions before Use ……………………………………………………………………………1-2 Description of Air Conditioner Components……………………………………………….
- 1 - Operation and Maintenance ◆ Instructions before Use Carefully read the following instructions before use Warning ★ Do not use flammable liquids on or near this air conditioner. ★ Touching metal parts after rem oving filter can cause an electric shock.
- 2 - ◆ Instructions before Use ★ Don’t attempt to repair the air conditioner by yourself. There are no user replaceable parts. Please contact your authorized dealer. ★ Always use new batteries in your remote. Never mix batteries. ★ Be sure to turn the power off when not using the air conditioner for a long time.
- 3 - ◆ Description of Air Conditioner Components Air intake Air outlet On/Off Swi tch Connecting Pipe / Line set On/Off Switch Signal Sensor.
- 4 - ◆ Remote Control Operation Function-Remote control Note: • Don't drop the remote control. • Don't place the remote control in a location exposed to direct sunlight. • When the unit is restarted after stopped, it will au tomatically resume its last running mode, and the outdoor unit will start there after.
- 5 - ◆ Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. ON/OFF Button Press ON. Press OFF. T-ON Button. When pressing this b utton once, enter in to T-ON setting, the icon of T-ON flash, every press of TIME+, the time of T-ON will be increased 1min.
- 6 - ◆ Remote Control Operation (Continued) The General Procedure: 1. Press ON/OFF button to start the unit. 2. Press MODE button to select the suitable operation mode. 3. Press SWING button to swing. It will stop when pressed again. 4. Press FAN button to set desired fan speed.
- 7 - ◆ User Notices ★ Select the most comfortable temperature. ★ The airflow direction can be adjusted. At operating, adjust the ve rtical airflow direction by adjusting the louvers of upward/downward direction. And then, hold two ends of left and right louver to adjust the horizontal airflow.
- 8 - ◆ Care and Maintenance CAUTION: Turn power off and pull out the power cord before cleaning air conditioner. Never sprinkle water on the i ndoor unit and the outdoor unit fo r cleaning because it can cause an electric shock. Volatile Liquid (e.
- 9 - ◆ Care and Maintenance (Continued) 3. Reinsert the filters Reinsert the filters along the direction of arrow, then cover the surface panel and clasp it. Check before Use 1. Be sure that nothing ob structs the air outlet and intake vents. 2. Verify that the unit is properly grounded.
- 10 - ◆ Trouble Shooting Problem Trouble Shooting Sound of water flow can be heard during operation. This is caused by the refriger ant flowing inside the unit. Mist is emitted during cooling operation. Because the air of the room is cooled down rapidly.
- 11 - ◆ Specifications and Technical Data Model KFHHP-22-ID / KFHHP-22-OD Function Heating and Cooling Cooling capacity(BTU/hr) & (Watts) 22000 / 6450 (2250-7000) Heating capacity(BTU/hr) & (Watts) 24200 / 7100 (1650-8500) Rated voltage 208-230V ~ Rated Frequency 60Hz Cooling/Heating ra ted current(A) 10.
- 12 - Installation Services ◆ Installation Diagram Important Notes The installation must be done by trained and qualified service personnel..
- 13 - ◆ Installation Location Indoor Unit 1. The inlet and outlet should not be covered so th at the outflow air can re ach all parts of the room. 2. Install in a location from which the condens ation water can be drained out conveniently. 3. Avoid a location where there is heat source, steam or flammable gas.
- 14 - ◆ Installation Install the rear panel 1. Always mount the rear panel horizontally. Becau se th e mouth of drainage pipe is at the left side and the left side of the rear panel is better to adjust slightly lower. 2. Fix the rear panel on the selected location with screws supplied with the unit.
- 15 - ◆ Installation Wiring of indoor unit Note: The power of indoor unit is su pplied by the outdoor. A breaker need s to be installed for safety. Operation Procedures: 1. Open the surface panel. 2. Open the cover and cover plate of electric box. (Right figure) 3.
- 16 - ◆ Installation Electric Wiring Note: Wiring must be done by a certified technician ac cording to the local rules & regulations. T he connecting wire should be correctly connected to ci rcuit interface. Otherwise, it can cause a fire, electricity leakage and so on.
- 17 - ◆ Installation Wiring of Outdoor unit Operation Procedures: • Open the cover of outdoor unit. • The connecting wire led from the terminal board of indoor unit should be connected correctly. • The connecting wire should be a little longer so that it can easily maintained.
- 18 - ◆ Installation Install the Power Line 1. Remove the front side plate. 2. Break through the hole for wires and put on the rubber bushing. 3. Pull all wires through the rubber bushing.
- 19 - ◆ Installation Install the Outdoor Unit Install the connection pipe: • Align the center of the piping flare with the valve. • Screw in the flare nut by hand and then tighten the nut with spanne r and torque wrench refer to right figure. Note: Exceeding tightening torque will damage the fla re nut.
- 20 - ◆ Installation Air Purging and Leakage Test 1. Connect charging hose of manifold value to charging end of low pressure valve (both high/low pressure valves must be tightly shut). 2. Connect joint of charging hose to vacuum pump. 3. Fully open handle of Lo manifold valve.
- 21 - ◆ Test Operation and Check after Installation Test Operation 1. Test Operation (1) Do not switch on power before installation is finished completely. (2) Electric wiring must be connected correctly and s ecurely (3) Cut-off valves of the conn ection pipes should be opened.
- 22 - Electrical Schematic Diagram ◆ Electrical Schematic Diagram (Indoor Unit) Please Help Insert Diagram in here..
- 23 - ◆ Electrical Schematic Diagram (Outdoor Unit) Please Help Insert Diagram in here..
- 24 - Warranty Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air Conditioner (KFHHP-22-ID/KFHHP-22-OD) to be free of defects in material and workmanship for the applications specified in its operation instruc tion for th e period of parts specified below.
An important point after buying a device Soleus Air KFHHP-22-ID (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Soleus Air KFHHP-22-ID yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Soleus Air KFHHP-22-ID - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Soleus Air KFHHP-22-ID you will learn all the available features of the product, as well as information on its operation. The information that you get Soleus Air KFHHP-22-ID will certainly help you make a decision on the purchase.
If you already are a holder of Soleus Air KFHHP-22-ID, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Soleus Air KFHHP-22-ID.
However, one of the most important roles played by the user manual is to help in solving problems with Soleus Air KFHHP-22-ID. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Soleus Air KFHHP-22-ID along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center