Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-18-ID / KFHHP-18-OD Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference . Indoor Unit .
TABLE OF CONTENTS USE AND MAINTENANCE……………………………..…………………………………….....1-14 Precautions on Use …………………………………………………………………..……………1-3 Specifications and Technical Data………………………………………………………………….
- 1 - Use and Maintenance ◆ Precautions on Use Carefully read the following precautions before use Warning ★ In case of malfunction (e.g. burnt smell), cut off the power supply immediately and then contact the Authorized Service Center (626-820- 1436).
- 2 - ◆ Precautions on Use ★ Grounding: The un it must be properly grounded. ★ Set the room temperature appropriately. ★ Close all doors & windows for efficient operat ion. ★ Never block the air inlet or ou tlet of indoor and outd oor unit .
- 3 - ◆ Precautions on Use ★ Adjust the ai r flow and direction properly. When the air c onditioner i s runni ng, you can p ress the SWING key on the remote control to adjust the guide louver and change th e direction of air flow. ★ To avoid in jury or dam age, never stick your fingers or any other object in to the unit.
- 4 - ◆ Specifications and Technical Data Model KFHHP-18-ID / KFHHP-18-OD Function Heating and Cooling Cooling capacity(BTU/hr) & (Watts) 18000 / 5300 (1400- 6000) Heating capacity(BTU/hr) & (Watts) 20000 / 6000 (1100- 7000) Rated voltage 208-230V ~ Rated Frequency 60Hz Cooling/Heating rated current(A) 10.
- 5 - ◆ Instructions for Use Principle and Special Functions during Cooling Mode Principle: The air conditi oner absor bs heat from indoor air a nd transm its it outdo ors for disc harge, hence to dec rease the i ndoor ambient temperature. The cooling ca pacity decreases with the rise of outd oor ambient temperature.
- 6 - ◆ Description of Air-Conditioner Components (1) Front Panel (2) Guide Louver (3) Remote Sensor (4) Wall Pipe (5) Wrapping Tape (6) Drainage hose (7) Connection pipe.
- 7 - ◆ Remote Control Operation Function-Remote control Note: • Don't drop the remote control. • Don't place the remote control in a location exposed to direct sunlight. • When the unit is restarted after stopped, it will au tomatically resume its last running mode, and the outdoor unit will start there after.
- 8 - ◆ Remote Control Operation (Continued) Liquid Crystal Display. It shows all set contents. ON/OFF Button Press ON. Press OFF. T-ON Button. When pressing this b utton once, enter in to T-ON setting, the icon of T-ON flash, every press of TIME+, the time of T-ON will be increased 1min.
- 9 - ◆ How to Insert Batteries 1. Remove the cover from the back of the remote control. 2. Insert the two batteries (T wo AAA dry-cell batteries). 3. Re-attach the cover. NOTE: • Don’t mix different batteries. • Remove batteries when not in use for a longtime.
- 10 - ◆ Cleaning and Maintenance • Be sure to cut off the power supply before cleani ng the air conditioner; otherwise electric shock might occur. • Liquids on the air conditioner may cause the risk of el ectric shock. Make sure not to spray wash your air conditioner in any case.
- 11 - ◆ Cleaning and Maintenance ③ Installing the air filter Mount the air filter in the direction of the arrows. Then, clamp the cover of front panel securely. Check before Seasonal Use ① Check the air inlet/outlet on indoor and outdoor u nits for any blockage.
- 12 - ◆ Trouble-Shooting Do not repair by yourself. Incorrect repair may cause electric shock or fire, so please contact the Authorized Service Center for professional repair. Fault Cause Analysis Air conditioner does not ru n upon immediate restart after a stop.
- 13 - ◆ Trouble-Shooting Fault Cause Analysis Air conditioner does not ru n. • Power failure ? • Circuit protection device tripped? • The voltage is to o high or too low? ( Refer to Page 15). (To be tested by professional technicians). • Timer function is correctly used? ( Refer to Page 7).
- 14 - ◆ Trouble-Shooting Fault Cause Analysis No air blows out from indoor un it. • When the temperature of i ndoor heat exchanger is low during heating process, the indoo r unit will stop blowing to prevent blowin g of cold air (within 3 minutes).
- 15 - Installation Services ◆ Precautions on Installation Important Caution 1. The air-conditioning unit m ust be installed by profession al technicians in accordance with the state and local codes. 2. Contact the local installation and service agency b efore installation.
- 16 - ◆ Precautions on Installation 4. Ensure safe grounding and the gr ounding wire shall b e connected with the special groundin g equipment of the building and m ust be instal led by profe ssional t echnician s. In the fixed line there mu st be an electrical leakage protection switch and an air switch w ith sufficient capacity.
- 17 - ◆ Installation Dimension Drawing.
- 18 - ◆ Install Indoor Unit Installing Wall-Mounting Frame 1. Level with plumb line or spirit level. As the drain outlet is on left side, it is better that the left side shall be lower when adjusting the wall-mounted board. 2. Use screws to secure the wall-mounting frame on the wall.
- 19 - ◆ Install Indoor Unit Notes: If the connecting cable is not long enough, please contact your distributor for a piece of special cable with sufficient length. No joints are allowed in the middle of the cable. • Be sure to connect the cable correctly.
- 20 - ◆ Install Outdoor Unit Power Cable Connection 1. Remove the handle at t he right side plate of t he outdoor unit (one screw). 2. Remove the ca ble clamp, conn ect the power connection cable with the terminal at the row of connection and make the connection.
- 21 - ◆ Install Outdoor Unit Check Items After Installation Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises Has the refri.
- 22 - Electrical Schematic Diagram ◆ Electrical Schematic Diagram (Indoor Unit).
- 23 - ◆ Electrical Schematic Diagram (Outdoor Unit).
- 24 - Warranty Soleus International Inc. warrants the accompanying Soleus Air Wall Mounted Mini Split Heat Pump Air Conditioner (KFHHP-18-ID/KFHHP-18-OD) to be free of defects in material and workmanship for the applications specified in its operation instruc tion for th e period of parts specified below.
An important point after buying a device Soleus Air KFHHP-18-ID (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Soleus Air KFHHP-18-ID yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Soleus Air KFHHP-18-ID - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Soleus Air KFHHP-18-ID you will learn all the available features of the product, as well as information on its operation. The information that you get Soleus Air KFHHP-18-ID will certainly help you make a decision on the purchase.
If you already are a holder of Soleus Air KFHHP-18-ID, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Soleus Air KFHHP-18-ID.
However, one of the most important roles played by the user manual is to help in solving problems with Soleus Air KFHHP-18-ID. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Soleus Air KFHHP-18-ID along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center