www .soehnle-pro fessional.com F OR MEASURABLE SUCCESS 3020 Operating Manual Ba_3020_GB.qxd 21.06.2007 19:08 Seite 1.
English 2 2 Content s 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Introduction . . . . . . . . . . . . . . . . . . .Page 3 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Basic Functions . .
English 3 3 Thank you for choosing this Soehnle Professional product. All the features of this product were designed to the state of the art and are optimised for simple and straightforward use.
English 4 4 1.3 Inst allation and commissioning Before connecting up the appliance, make sure that the power supply complies with the specifica- tions on the appliance nameplate, and the power plug version conforms to local regulations. Place the connected scales on a level and stable surface.
Program mode Here, select the required weighing application program. After selecting and activating the application program, the scale is ready to operate. Function key The F function key is for calling up functions. It assumes different functions depending on how it is assigned.
English Input and control keys The following keys are available for input and control: Numeric keys to type in numerical values Multiple programming of numeric keys to type in alphabetic characters Ca.
Display The display shows a number of situative views. It is divided into display panes. Additional indicator: Displays second units, weight values for counting, differences with setpoint, etc. Press the F key to activate as required. Symbol bar: Displays information on the status of the activated measuring point.
English 8 8 2. Basic functions The basic functions are similar or identical for all application programs. 2.1 Power on/off Power-on After power-on and during the run-up phase, the Soehnle Professional logo is displayed. The measuring points are briefly listed as they are detected.
English 9 9 2.3 Zeroing Press the zeroing key to correct minor deviations from the zero point, e.g. caused by soiling on the scale. Zero range approvable and non-approvable: -1% to +3% of the weighing range.
English 1 1 0 0 2.6 Organisation dat a (identifiers) Organisation data help to assign identifiers to document weighing operations, e.g. article number , supplier , machine operator . They are available in all application programs. The Digital Indicator 3020 has 4 organisation data memories.
English 1 1 1 1 Printout: When an ORG data memory is activated and a print template is stored, values are accepted when you press the Print key and generates a print command. Only the organisation data containing an input are printed out. Show content: Press the ORG key .
English 1 1 2 2 2.9 Alphanumeric input Use the combined numerical/alphanumeric keypad to type in numerical and alphanumeric inputs (similar to a mobile phone keypad).
English 1 1 3 3 3.0 Application programs The various application programs of the Soehnle Program T erminal 3020 offer you numerous solutions for your weighing operations. Y ou can adapt the application programs to your specific needs in Setting mode. Please refer to the detailed manual on the CD under the heading "Setting mode".
English 1 1 4 4 3.1.3 W eighing without t aring Place weighing product on the scale. The weight is indicated with the message "Gross". 3.1.4 Manual t aring Measure and tare with a container of unknown weight. Place the empty container on the scale.
English 1 1 5 5 3.1.6 Additive t are T aring several, even different containers of known weight. See the description of the function in the CD manual. 3.1.7 Provisional t are Unknown tare values are added to the existing tare memory . See the description of the function in the CD manual.
English 1 1 6 6 b) Changing or overwriting a fixed tare value memory • Press the Print key and the F key simultaneously; Setting mode appears in the display . • The arrow points to "Program Settings". Confirm by pressing the Print key . • The arrow points to "General".
English 1 1 7 7 3.1.10 Error message when t aring Error 06: Not possible to tare Possible causes: - Scale empty - Scale in overload or underload - Manual tare input with tare value above maximum load 3.
English 1 1 8 8 3.2 T ot alising and batching T otalising means that the individual items are weighed one after the other , the weight is added in the total memory and the scale is then clipped off again at the end of each weighing operation.
English 1 1 9 9 3.2.3 T aring T aring functions same as for 3.1 Weighing and taring. 3.2.4 Operating the tot alising functions Press the F key to transfer the weight on the weighing platform to the total memory . The item counter and the consecutive number are incremented by 1.
English 2 2 0 0 3.2.8 Assigning and clearing the consecutive number Every input in the total memory is assigned a 4-digit consecutive number . The consecutive number is not reset to the factory setting when the total memory is cleared.
English 2 2 1 1 3.3 Counting Counting parts with the same weight. The single part weight (reference weight) is calculated from a known small quantity of countable part s. This then becomes the divisor to determine the piece count from the weight of an unknown quantity of countable part s.
English 2 2 2 2 Displaying the reference weight Press the "Info" and "F" keys in succession. Weight display during the counting operation The weight display appears at the top left of the indicator . T erminate the count operation by pressing the C key .
English 2 2 3 3 Saving the new fixed value Entering a new reference value only works in Setting mode "Count/Reference weight fixed value". The memory location number is assigned by the appliance.
English 2 2 4 4 3.4 Checking Checks whether the weighing product corresponds to a setpoint weight within a default. tolerance band. Example: If you want to check whether several weighing products This function can also be used for weighing in a default setpoint.
English 2 2 5 5 4. Further information Y ou will find further information on the following subjects in the detailed document ation, the Program T erminal 3020 manual, on the supplied CD: - Setting mode - Error messages - Print - Barcode - etc. Ba_3020_GB.
English 2 2 6 6 Ba_3020_GB.qxd 21.06.2007 19:08 Seite 26.
English 2 2 7 7 Ba_3020_GB.qxd 21.06.2007 19:08 Seite 27.
www .soehnle-pro fessional.com F OR MEASURABLE SUCCESS Soehn le Pr o f essional Gm bH & Co. K G Manfred-von-Ardenne-Allee 12 71 522 Backnang Te l e fo n +4 9 (0) 71 9 1 / 34 53 -22 0 Te l e fa x +49 (0) 7 1 9 1 / 34 53 -2 11 E-Mail inf o@soehnle-pro f e ssional.
An important point after buying a device Soehnle 3020 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Soehnle 3020 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Soehnle 3020 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Soehnle 3020 you will learn all the available features of the product, as well as information on its operation. The information that you get Soehnle 3020 will certainly help you make a decision on the purchase.
If you already are a holder of Soehnle 3020, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Soehnle 3020.
However, one of the most important roles played by the user manual is to help in solving problems with Soehnle 3020. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Soehnle 3020 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center