Instruction/ maintenance manual of the product FP410 Shure
Go to page of 9
Model FP410 User Guide Shure Brothers Incorporated 222 Hartrey A venue Evanston IL 60202-3696 U.S.A. 27A8319 (PK) 1996, Shure Brothers Inc. Printed in U.S.A. The Shure Model FP410E is an automatic microphone mixer de - signed for use in a wide variety of multi–microphone speech pickup applications.
Copyright 1992, Shure Brothers Inc. 27A8319 (LG) Printed in U.S.A. U.S. Patent 4,658,425; other patents pending 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 4 3 2 LINK .
2 3. Input High Red LED: Should flicker only on loud speech peaks. 4. Flat ( — )/Low–Cut ( / ) Slide Switches: Provide low–frequen - cy rollof f to reduce undesirable low–frequency signals such as wind noise. 5. MASTER Rotary Control: Determines the level of the com - bined input signals at Mic/Line, T ape and Phones outputs.
3 shielded cables). Adjust Mic/Line switches as required for incoming signal level. 3. If phantom–powered condenser microphones are used, turn on the FP410E’ s Phantom Power switch. NOTE: With condenser microphones other than Shure, verify that volt- age and source resistance requirements are compatible.
4 condenser microphones to be used are compatible with the selected voltage. If the microphones can operate properly with 14 V phantom power , that position should be used to avoid ex - cessive battery drain. INTERNAL MODIFIABLE FUNCTIONS W ARNING V oltages in this equipment are hazardous to life.
5 Right Rack–Mount Bracket 53A8253 . . . . . . . . . . . . . . . . . . SPECIFICA TIONS Measurement Conditions (unless otherwise specified): Line voltage 230 V ac, 50/60 Hz; full gain; 1 kHz, one cha.
6 Inputs Impedance Input Designed for use with Actual (In - ternal) Input Clip- ping Level Mic 19–600 Ω 900 Ω –15 dBV Line ≤ 10 k Ω 66 k Ω T o > +26 dBV Monitor ≤ 1 k Ω 25 k Ω +21 dBV Outputs Impedance Output Designed for use with Actual (In - ternal) Output Clipping Level Mic Any low– impedance mic input 0.
7 Questions & Answers Questions about your FP410E installation? This section lists the most common questions asked about Shure’s auto- matic microphone systems. Maybe your question is among the following. If not, contact Shure’ s Customer Service Depart - ment.
A TTEN PHANTOM POWER LOW-CUT BALANCED MIC/LINE INPUT CHANNE L LEVEL INDICA TORS INTELLIMI X CONTROL AUTO MANUAL IN OUT LIN K J ACKS CHANNEL S 2 , 3, 4 CHANNEL LEVEL GA TED SIGNALS NON-GA TED SIGNALS 1.
An important point after buying a device Shure FP410 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Shure FP410 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Shure FP410 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Shure FP410 you will learn all the available features of the product, as well as information on its operation. The information that you get Shure FP410 will certainly help you make a decision on the purchase.
If you already are a holder of Shure FP410, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Shure FP410.
However, one of the most important roles played by the user manual is to help in solving problems with Shure FP410. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Shure FP410 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center