Instruction/ maintenance manual of the product X7501920500 Shindaiwa
Go to page of 28
Minimize the risk of injury to yourself and oth- ers! Read this manual and familiarize yourself with the contents. Always wear eye and hearing protection when operating this unit.
2 T able of Contents CA UTION! A statement preceded by the word “CAUTION” contains information that should be acted upon to avoid damaging the unit.
3 WARNING! Never make unauthorized modi- cations or attachment installa - tions. Never use attachments not approved by Shindaiwa for use on this unit. W or k Safely Blowers operate at a very high speed and can do serious damage or injury if they are misused or abused.
4 Wear a dust mask to reduce the risk of inhalation injuries. Always wear eye protection such as a face shield or goggles while operating this unit. Never operate the blower when visibility is poor . Wear hearing protection when operating this unit. Wear close-tting clothing to protect legs and arms.
5 Unit Description Figure 3 IMPORT ANT! Safety and Operation Information Labels: Make sure all information labels are undamaged and readable. Immediately replace damaged or missing information labels. New labels are available from your local authorized Shindaiwa dealer .
6 An Emission Control Label is located on the unit. (This is an EXAMPLE ONL Y ; information on label varies by en- gine F AMIL Y). PRODUCT EMISSION DURABILITY (EMISSION COMPLIANCE PERIOD) The 300 hour.
7 Assembling the Blow er Place the blower upright on the ground or on a sturdy work surface. 1. Grasp the blower tube as shown, and push the tube over the blower dis- charge port and locking pins. 2. Lock the blower tube to the blower discharge port by rotating the tube as shown.
8 Handling Fuel D ANGER Fuel is VERY ammable. Use extreme care when mixing, storing or handling or serious personal injury may result. • Use an approved fuel container . • DO NOT smoke near fuel. • DO NOT allow ames or sparks near fuel. • Fuel tanks/cans may be under pressure.
9 Storage - Fuel storage laws vary by locality . Contact your local govern- ment for the laws affecting your area. As a precaution, store fuel in an ap- proved, airtight container . Store in a well-ventilated, unoccupied building, away from sparks and ames.
10 WARNING! Never operate the blower unless all controls are properly installed and in good working order . Never operate the blower if the cylinder cover is missing or damaged! If T he Engine Does Not Star t– Repeat the appropriate starting procedures for warm or cold engine.
11 Operating Blow er WARNING! Engine exhaust IS HOT , and contains Carbon Monoxide (CO), a poison gas. Breathing CO can cause un- consciousness, serious injury , or death. Exhaust can cause serious burns. AL WA YS position unit so that exhaust is directed away from your face and body .
12 IMPORT ANT! T o avoid engine damage due to over-revving do not block blower pipe. 1. Use only during appropriate hours. 2. Control engine speed with throttle lever , or for continuous use, set en- gine speed with throttle lock lever . 3. Use lower speed to blow debris from hard surfaces.
13 Maintenance Inter vals COMPONENT / SYSTEM MAINTENANCE PROCEDURE DAILY OR BEFORE USE EVERY REFUEL 3 MONTHS OR 135 HOURS YEARLY 600 HOURS Air Filter Inspect/Clean I / C * R * Choke Shutter Inspect/Cl.
14 Unscrew Fasteners Figure 13A Figure 13B Filter Element Pre-Filter 1. Remove the air cleaner cover by loosening the thumb screw and lifting up. See Figure 13A. 2. Remove and inspect the pre-lter . If the pre-lter is torn or otherwise dam - aged, replace it with a new one.
15 0.6mm (0.024 in.) CA UTION! Never allow dirt or debris to enter the cylinder bore! Before remov- ing the spark plug, thoroughly clean the spark plug and cylinder head area! Allow the engine to cool.
16 CAUTION! • Performing a valve adjustment incorrectly may cause hard start - ing and/or can damage the unit. • If you are unfamiliar with this engine or uncomfortable with this procedure, consult with an authorized Shindaiwa servicing dealer . V alve Adjustment 1.
17 Spark Arrester Maintenance WARNING! Never operate this blower with a damaged or missing mufer or spark arrester! Operating with missing or damaged exhaust components is a re hazard, and can also damage your hearing! Hard starting or a gradual loss of performance can be caused by carbon deposits lodged in the spark arrester screen.
18 Idle Adjustment Before adjustment make sure that: • Air lter is clean and proper l y installed. • Spar k ar r estor screen is fr ee of carbon. • Blower pipes are installed. 1. Start engine, run at idle for 2-3 minutes. 2. Check idle speed and reset if necessary .
19 T roubleshooting Guide V aporlock. V alve adjustment. Engine hot/heat soaked. Low fuel quality . V alve clearance too tight. V alve clearance too loose.
20 ADDITIONAL PROBLEMS Poor acceleration. Clogged air lter . Clogged fuel lter . Lean fuel/air mixture. Idle speed set too low . Ignition switch turned off. Fuel tank empty . W ater in the fuel. Clogged fuel lter . Shorted spark plug or loose terminal.
21 ADDITIONAL PROBLEMS Poor acceleration. Clogged air lter . Clogged fuel lter . Lean fuel/air mixture. Idle speed set too low . Ignition switch turned off. Fuel tank empty . W ater in the fuel. Clogged fuel lter . Shorted spark plug or loose terminal.
22 SHINDAIW A LIMITED W ARRANTY ST A TEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010 ECHO, INC'S RESPONSIBILITY ECHO Incorporated’s (ECHO, INC.) Limited W arranty , provides to the original purchaser that this Shindaiwa product is free from defects in material and workmanship.
23 PURCHASED REP AIR P ARTS AND ACCESSORIES • 90-day all applications A TTENTION ENGINE POWERED PRODUCT OWNERS This Shindaiwa engine powered product is a quality-engineered unit which has been manufactured to exact tolerances to provide superior performance.
24 ECHO INCORPORA TED EMISSION CONTROL W ARRANTY ST A TEMENT FOR ECHO AND SHINDAIW A BRANDS The Environmental Protection Agency (EP A) and the California Air Resources Board (C.A.R.B.) and ECHO Incorporated (ECHO Inc.) are pleased to explain the emission control system warranty on your 2010 and later equipment/small off-road engine (SORE).
25 NO TES.
26 NO TES.
27 NO TES.
ECHO Incorporated. 400 Oakwood Road Lake Zurich, IL 60047-1564 U.S.A. T elephone: 1-877-986-7783 Fax: 1-847-540-8416 www .shindaiwa.com Y amabiko Corporation 7-2 Suehirocho 1-Chome, Ohme, T okyo, 198-.
An important point after buying a device Shindaiwa X7501920500 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Shindaiwa X7501920500 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Shindaiwa X7501920500 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Shindaiwa X7501920500 you will learn all the available features of the product, as well as information on its operation. The information that you get Shindaiwa X7501920500 will certainly help you make a decision on the purchase.
If you already are a holder of Shindaiwa X7501920500, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Shindaiwa X7501920500.
However, one of the most important roles played by the user manual is to help in solving problems with Shindaiwa X7501920500. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Shindaiwa X7501920500 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center