Instruction/ maintenance manual of the product Sentry Xpress 4.0 Sentry Industries
Go to page of 16
The Sentry Xpress 4.0 micro processor is manufactured by the Orton Ceramic Foundation and displays the CE mark. Hr ./Min. When Lit HIGHER °C °F When Off When Lit ST ART/ STOP L OWER Program Review Run MICRO PROCESSOR TM SENTRY Xpress 4.0 Enter Program Skip Seg.
2 Single-Speed/Ramp-Hold ©2004, by Paragon Industries, L.P. IM-221/2-06 Contents General Guidelines . . . . . . . . . . . . . . . . . 3 Time and Temperature Display . . . . . . . . . . . . . . . . . . . 3 Operation Begins from the IdLE Display . . . .
3 General Guidelines Time and Temperature Display Center Dot: Time A center dot appears dur - ing time display. It separates hours from minutes. (Exam - ple: 1 hour, 30 minutes dis - plays as 01.30.) During tem - perature display, the dot disappears. Right-Hand Dot: °C When temperature is displayed in °C, a dot appears in the lower right.
4 Single-Speed/Ramp-Hold Note: Press during delay to end the delay and begin the firing. The maximum delay is 99 hours and 59 minutes. Power Failures After a power failure, the controller will continue firing provided that: I The kiln temperature is above 212°F / 100°C when the power comes back on.
5 Rate Each segment must include a rate, which is degrees of temperature change per hour. The kiln will fire at full power when the rate is 1799°F/999°C. Full power displays as . Note: To enter full power from , press the key once. Hold Hold is the length of time that you want the kiln to re- main at the target temperature.
6 Single-Speed/Ramp-Hold Ramp-Hold programs in memory. Programs are numbered Pro1 - Pro4. Type of Firing Suggested Firing Mode Enameling Single-Speed Silver Clay Single-Speed Glass Bead Annealing Ramp-Hold Glass Fusing Ramp-Hold Glass Slumping Ramp-Hold Lost Wax Ramp-Hold Selecting a Firing Mode From display, press once.
7 Rate Temp. Segment °F/°C °F/°C Hold 1 500/277 1450/788 00.00 2 100/55 700/371 00.00 The first segment is the heating segment. The second one is the cooling segment. The controller does not use mi - nus numbers for cooling. Just enter a lower target tempera - ture than that of the previous segment.
8 Single-Speed/Ramp-Hold Advanced Fe a t u r e s Skip Segment works only in Ramp-Hold programs. Add Hold Time, Temperature Edit, and Alarm work in both Single-Speed and Ramp-Hold firings. Skip Segment Skip Segment jumps the firing from the current segment to the next one.
9 Lost W ax Burnout CAUTION: Only kilns with vent holes are designed for lost wax burnout. However, you may be able to use a kiln without the vent hole provided that you open the door ½” during venting.
10 Single-Speed/Ramp-Hold Display Messages (Page 9) Ready for you to enter an alarm temperature. When the kiln reaches that tempera - ture, the alarm will sound. ( also flashes when the alarm sounds.) (page 9) Ready for you to edit the target temperature of the current Ramp-Hold segment during firing.
11 (pages 7, 8) These are Ramp-Hold programs stored in memory. etc. (Rate) (page 8) This appears in Ramp-Hold programming for each segment. 1, 2, etc. are segment numbers. Enter the rate of temper - ature change for that segment. Rate is figured in de - grees of temperature change per hour.
12 Single-Speed/Ramp-Hold FE Error Messages FE 1 Memory Read/Write Failure FE 2 RAM Failure FE 3 OEM Factory Data Corruption FE 4 Thermocouple “Noise” FE 5 Software Error To return to from an FE code Try pressing any key. If that doesn’t work, turn the power off for 10 seconds.
13 T rouble Shooter Problem: Controller display is blank. No heat in kiln. I Is the kiln connected to the power? I Has the circuit breaker tripped or fuse blown? I Is power reaching the wall receptacle? Test with a voltmeter or a test light if you are not sure.
14 Single-Speed/Ramp-Hold Problem: Controller display turns on. No heat in kiln. I Is the relay making its normal clicking sound? Test the elements with an ohmmeter: Element Resistance Test UNPLUG kiln/disconnect the power. Open the kiln’s switch box.
15 Index Add Hold Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 bAdP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 Single-Speed/Ramp-Hold Shorthand Instructions These instructions may be confusing until you have read more detailed instructions on Single-Speed, page 6, or Ramp-Hold, page 8. Read the safety guidelines, page 3. After pressing the keys in left column, the center message will appear.
An important point after buying a device Sentry Industries Sentry Xpress 4.0 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sentry Industries Sentry Xpress 4.0 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sentry Industries Sentry Xpress 4.0 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sentry Industries Sentry Xpress 4.0 you will learn all the available features of the product, as well as information on its operation. The information that you get Sentry Industries Sentry Xpress 4.0 will certainly help you make a decision on the purchase.
If you already are a holder of Sentry Industries Sentry Xpress 4.0, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sentry Industries Sentry Xpress 4.0.
However, one of the most important roles played by the user manual is to help in solving problems with Sentry Industries Sentry Xpress 4.0. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sentry Industries Sentry Xpress 4.0 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center