Instruction/ maintenance manual of the product LYON SERIES IDE ST760211DE Seagate
Go to page of 46
Product Manual Ly r i o n S e r i e s I D E 100462437 Re v . B Ma y 2007 ST76021 1DE ST730212DE.
Revision history Copyright © 2007 Seagate T echnology LLC. All right s reserved. Printed in U.S.A. Publication number: 100462437, Rev . B May 2007 Seagate, Seagate T echnology an d the W ave logo ar e registere d trademarks of Seagate T echnology LLC in the United S tates and/or other countries.
Lyrion Series IDE Product Manual, Rev. B i Contents 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Disclaimer . . . . . . . . . . . . . . . .
ii Lyrion Series IDE Product M anual, Rev. B.
Lyrion Series IDE Product Manual, Rev. B iii List of Figures Figure 1. Lyrion Series (IDE interface) disc drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Figure 2. Typical 3.3V startup and operat ion current profile .
iv Lyrion Series IDE Product M anual, Rev. B.
Lyrion Series IDE Product Manual, Rev. B 1 1.0 Introduction This manual describes th e functional, mechanical a nd interface spe cifications for the following Seagate ® Lyr io n Series ® IDE drives: • ST76021 1DE-60GB, ST730212DE-30GB disc drives with an IDE interface.
2 Lyrion Series IDE Product M anual, Rev. B 1.1 Disclaimer Seagate T echnology LLC makes no warranties whatsoever , including any wa rranty of merchan tabili ty , non- infringement, fitness for any particular pu rpose, or any warra nty otherwise ar ising out of any pro posal, specification or sample.
Lyrion Series IDE Product Manual, Rev. B 3 2.0 Drive specifications Unless otherwise noted, all specific ations are me asured unde r ambient conditions, at 25°C, and nominal power . For convenience, the phrases th e drive and this drive are used thr oughout this manual to indicate ST76021 1DE and ST730212DE model drives.
4 Lyrion Series IDE Product M anual, Rev. B 2.2 Formatted cap acity LBA mode addressing When addressing these d rives in LBA mode, all bloc ks ( sectors) are consecutively numbered from 0 to n–1, where n is the number of guara nteed sectors as defined above .
Lyrion Series IDE Product Manual, Rev. B 5 2.4 Recording and interface tec hnology 2.5 Physical characteristics 2.6 Time to rea dy T echno logy Specification Interface IDE (Parallel A T A) Recording m.
6 Lyrion Series IDE Product M anual, Rev. B 2.7 Power specifications The drive receives DC power (+3.3V) through the ZIF conn ector (IDE interface). 2.
Lyrion Series IDE Product Manual, Rev. B 7 * Maximum is the average of t he peak value in 10 msec window 2.7.1.1 T ypical current profile Figure 2. T ypical 3.3V s t artup and operation current profile T able 2: DC power Power Consumption at 3.3V A ve rage (W) S tartup (max*) 1.
8 Lyrion Series IDE Product M anual, Rev. B 2.7.2 Conducted noise Input noise ripp le is meas ured at the host sys tem po we r supply across an equivalent 15-ohm resistive load on the +3.3 volt line. Using 3.3-volt power , the drive is expect ed to operate with a ma ximum of 70 m V peak-t o-peak squa re-wave injected nois e at up to 20 MHz.
Lyrion Series IDE Product Manual, Rev. B 9 2.7.4 Po wer-manage ment mod es The drive provides pro grammable power management to pr ovide gr eater energy effici ency . The drive features the following power-ma nagement modes: • Active mode The drive is in Active mode during the r ead/write and seek operations.
10 Lyrion Series IDE Product M anual, Rev. B 2.8 Environment al specifications 2.8.1 Ambie nt temperat ure Ambient temperatur e is defined as the temperatur e of the environment im mediatel y surrounding the drive. Actual drive case tempera t ure should not exceed 70 °C (158°F) within the operating ambient conditio ns.
Lyrion Series IDE Product Manual, Rev. B 11 2.8.5 Sho ck All shock measurement s in this section are carried out at drive level. For all linear shock test, operating or nonoperating, th e in pu t sh ock level is m easur ed at the fra m e o f th e d rive at the sp ecif ic location as indicated in Figure 3 below .
12 Lyrion Series IDE Product M anual, Rev. B 2.8.6.1 Operating sweep sine vibration The following lists the maximum operat ing sweep sine vibration levels that the drive may experience whil e meeting the perfor mance standards s pecified. It consists of a forwar d and backward sweep from 10 Hz to 500 Hz to 10 Hz.
Lyrion Series IDE Product Manual, Rev. B 13 2.8.6.4 Nonoperating random vibration The test consist s of 15 minutes of random vibra tion usin g the power spectral density (PSD) levels specified in the table b e low . The vibration test level is 3.01 Gs RM S.
14 Lyrion Series IDE Product M anual, Rev. B 2.9 Acoustics Drive acoustics are measured as ove rall A-weighted ac oustic sound power lev els (no pure tones). Discr ete tone penalties are a dded to the A-weighted sound po wer (L W) with the following fo rmula only when determin - ing compliance: L Wt(spec) == L W + 0.
Lyrion Series IDE Product Manual, Rev. B 15 2.12 Agency certification 2.12.1 Safety certification The drives are re cognized in accordan ce with UL 60950-1, CAN/CSA-C22.
16 Lyrion Series IDE Product M anual, Rev. B 2.12.4 China Restriction of Hazar dous Subst ances (RoHS) Directive This product has an Envir onmental Protection Us e Period (EPUP) of 20 years.
Lyrion Series IDE Product Manual, Rev. B 17 If necessary , you should consult your dealer or an experienced radio /television technician for additional sug - gestions. Y ou may find helpful the following booklet prep ared by the F ederal Communications Commission: How to Identify and Resolve Radio-T elevision Interference Prob lems .
18 Lyrion Series IDE Product M anual, Rev. B.
Lyrion Series IDE Product Manual, Rev. B 19 3.0 Configuring and mounting the drive This section contains the specif ications an d instructions for configuring and mounting the drive.
20 Lyrion Series IDE Product M anual, Rev. B • Do not remove the factory-in stalled labels from the drive or cover th em with a dditional labels. Removal voids the warranty. Some factory-in stalled labels contain information needed to service the d rive.
Lyrion Series IDE Product Manual, Rev. B 21 3.2 Drive inst allation See Figure 7 for drive mechanic al dim en sio n s. Follow these inst alla tion precautions when inserting the drive: • Follow instructions for the installation of data storage devices , provided with your device’s user man u al.
22 Lyrion Series IDE Product M anual, Rev. B 3.3 Mounting considerations • Use an elas tic mountin g material t o protect d rives so as to ensure that more shock can be absorbed.
Lyrion Series IDE Product Manual, Rev. B 23 4.0 Interface description The drives use th e industry-standard A T A (IDE) interf ace. It supports A T A programmed inp u t/output (PIO) modes 0–4; multiword DM A mo des 0–2, and Ultra DMA modes 0–4. 4.
24 Lyrion Series IDE Product M anual, Rev. B 23 GROUND Ground 24 DIOW- / STOP I/O W rite to write to device registers or the data port S top during Ultra DMA bu rst 25 DIOR- / HDMARDY - / HSTROBE I/O .
Lyrion Series IDE Product Manual, Rev. B 25 4.2 Supported A T A commands The following t able lists A T A-st andard commands that the drive supp orts. For a de tailed description of the A T A commands, refer to A T A version 7 spec ification, V olume 1.
26 Lyrion Series IDE Product M anual, Rev. B T able 9: Supported commands W rit e DMA CAh DMA data-out Standby Im m ediate E0h Non data Idle I mm ediat e E1h Non data Standby E2h Non data Idle E3h Non.
Lyrion Series IDE Product Manual, Rev. B 27 4.2.1 Id entify Dev ic e command The Identify Device command (command code EC H ) tran sfers information about the drive to the host following power up. The dat a is organized as a single 512-byte (256 wor d) block of data, wh ose contents ar e as shown in the following table.
28 Lyrion Series IDE Product M anual, Rev. B 82 Command sets supported Bit 14: 1= NOP c ommand supported Bit 13: 1= READ BU FFER command supported Bit 12: 1= W RITE BUFFER co mmand supported Bit 10: 1.
Lyrion Series IDE Product Manual, Rev. B 29 The 512-byte dat a returned by the Identify Devi ce co mmand is show n in the table below . The last 256-byte a re vendor specific dat a and are for reference only . Word No. Value Word No. Value Word No. Value Word No.
30 Lyrion Series IDE Product M anual, Rev. B 4.2.2 S et Featu res command This command is us ed by the host to establish parameters that affect the exec ution of certain driv e features. The supported features d e termined by the value in the Features re gister are as shown in T able 10 .
Lyrion Series IDE Product Manual, Rev. B 31 4.3 Register default values The following t a ble descibes the t askfile register def ault values following Power On Reset, Hardware Reset and Softwar e Reset.
32 Lyrion Series IDE Product M anual, Rev. B.
Lyrion Series IDE Product Manual, Rev. B 33 5.0 Seagate T echnology support services Internet For information regarding Se agate products and ser vices, visit www .sea g ate.com . W orldwide support is available 24 hours da ily by email fo r your questions.
34 Lyrion Series IDE Product M anual, Rev. B Customer Service Operations W arranty Service Seagate of fers worldwide customer support fo r Seag ate products. Seagate d istr ibuto r s, OEMs and ot her direct customers should contact their Seagate Customer Serv ice Operat ions (CSO) re presentative for warr anty- related issues.
Lyrion Series IDE Product Manual, Rev. B 35 Publication feedback survey We ar e interested in your comment s and suggestions rega rding this publication . Please take a few minutes to participate in our survey at the following URL: http://survey .sea g ate.
36 Lyrion Series IDE Product M anual, Rev. B.
Lyrion Series IDE Product Manual, Rev. B 37 Index A acoustics 1 4 Active m ode 9 agency certification (regulatory) 15 altitude 10 ambient cond itio ns 3 ambient temperature 10 areal density 1 , 5 ATA-.
38 Lyrion Series IDE Product M anual, Rev. B N noise 8 nominal po wer 3 nonopera ting random vibration 13 nonoperating sh ock 1 , 11 Nonoperating sweep sine vibration 12 nonrecoverable re ad e rrors 1.
.
Seagate T echnology L LC 920 Disc Drive, Scotts V alley , California 95066-4544, USA Publication Number: 100462437 , Rev . B, Printed in U.S.A..
An important point after buying a device Seagate LYON SERIES IDE ST760211DE (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Seagate LYON SERIES IDE ST760211DE yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Seagate LYON SERIES IDE ST760211DE - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Seagate LYON SERIES IDE ST760211DE you will learn all the available features of the product, as well as information on its operation. The information that you get Seagate LYON SERIES IDE ST760211DE will certainly help you make a decision on the purchase.
If you already are a holder of Seagate LYON SERIES IDE ST760211DE, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Seagate LYON SERIES IDE ST760211DE.
However, one of the most important roles played by the user manual is to help in solving problems with Seagate LYON SERIES IDE ST760211DE. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Seagate LYON SERIES IDE ST760211DE along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center