Installation and User's Manual for Remote Condenser Modular Cuber Models: C0522, C0530, C0630, C0830 and C1030.
.
Introduction The design of this modular remote cuber is the result of years of experience with remote ice machine refrigeration systems. Standard features of this product include front accessible on-o.
Installation: Product Specifications Location Limitations This ice system is made up of three parts, the ice making machine, or head; the remote condenser; and the interconnecting tubing. The ice making machine must be installed indoors, in a controlled environment.
Model Number Description Example • C0630SR-32A • C=cuber • 06=nominal capacity in 100s of pounds • 30=nominal width of cabinet in inches • S=cube size, S=small or half dice, M=medium or full dice • R=condenser type. R=Remote • -32=Electrical code.
REMO TE COOLED BACK VIEW 1.43 3.6 3.04 7.7 10.79 27.4 14.56 37 6.11 15.5 1.69 4.3 2.02 5.1 7.58 19.2 11.12 28.2 19.00 48.3 19.71 50.1 .88" DIA ELECTRICAL AC CESS (2) 3/4" FPT DRAIN REMOTE C ONDENSER LIQUID LINE 3/8 MALE CPL G. REMOTE C ONDENSER DISCHARGE LINE 1/2 MALE CPL G.
C0530, C0630, C0830 and C1030 Cabinet Dimensions July 2006 Page 5 C0522 through C1030 Remote Condenser Models - User Manual PLAN VIEW 24.00 REF . 61 30.00 REF . 76.2 2.00 5.1 2.00 5.1 19.05 48.4 3.25 8.3 10.25 26 7.00 17.8 ICE DROP OPENING UL TRASONIC BIN LEVEL SENSOR (OPTIONAL) Top View REMOTE C OOLED BACK VIEW 1.
Product Description and Electrical Requirements Dimensions w ”xd ”xh ” Model Electrical Use condenser Minimum Circuit Ampacity Maximum Fuse Size* 22.75*** x 24 x 23 C0522SR-1 115/60/1 ERC111-1 14.9 15 same same same ERC211-1** 14.9 15 30.75*** x 24 x 23 C0530SR-1 115/60/1 ERC111-1 14.
Water The quality of the water supplied to the ice machine will have an impact on the time between cleanings and ultimately on the life of the product. Water can contain impurities either in suspension or in solution. Suspended solids can be filtered out.
Panel Removal 1. Locate and loosen the two screws at the front edge of the top panel. 2. Pull the front panel out at the top and lift it up and off the base. 3. Remove two screws at the front edge of the top panel, and lLift up the top panel until it clears the front of the side panels, then push back 1” and lift it up and off the machine.
Remote Condenser Location Use the following for planning the placement of the condenser relative to the ice machine Location Limits - condenser location must not exceed ANY of the following limits: .
For The Installer: Remote Condenser Locate the condenser as near as possible to the interior location of the ice machine. Note: The location of the condenser is relative to the ice machine is LIMITED by the specification on the prior page. Meet all applicable building codes.
Precharged Line Routing Do not connect the precharged tubing until all routing and forming of the tubing is complete. See the Coupling Instructions for final connections. 1. Each set of pre-charged tubing lines contains a 3/8” diameter liquid line, and a 1/2” diameter discharge line.
Coupling Instructions The couplings on the ends of the pre-charged line sets are self-sealing when installed properly. Follow these instructions carefully. These steps must be performed by an EPA Certified Type II or higher technician. Initial Connections 1.
Plumbing Requirements All models require connection to cold, potable water. A hand actuated valve within site of the machine is required. There is a single 3/8” FPT inlet water connection, a 3/8” FPT to 3/8” male flare adapter is supplied with the machine and can be used if desired.
Electrical The machine is not supplied with a power cord, one must either be field installed or the machine hard-wired. The dataplate on the back of the cabinet details the power requirements, including voltage, phase, minimum circuit ampacity and maximum fuse size.
Final Check List: 1. Is the unit located indoors in a controlled environment? 2. Is the unit located where it can receive adequate cooling air? 3. Has the correct electrical power been supplied to the machine? 4. Have all the water supply connections been made? 5.
Initial Start Up 1. Remove front and left side panels. Check machine for any packing or wires rubbing moving parts. Note location of control board in upper left corner of the machine ’s front. 2. Remove tape securing curtain to evaporator. 3. Switch on the electrical power to the machine.
Adjustments Bridge Thickness - For the Service Tech Only 1. Push and hold Off till the machine stops. 2. Remove evaporator cover. 3. Remove curtain. 4. Use a hex wrench and rotate the bridge thickness adjustment screw in 1/8 turn increments CW to increase bridge thickness.
Use and Operation Once started, the ice machine will automatically make ice until the bin or dispenser is full of ice. When ice level drops, the ice machine will resume making ice. Caution: Do not place anything on top of the ice machine, including the ice scoop.
Control Switches There is front access to two switches – On and Off. To switch the machine OFF, push and release the Off button. The machine will shut off at the end of the next cycle. To switch the machine ON, push and release the On button. The machine will go through a start up process and then resume ice making.
Options and Other Information Optional Advanced Feature Board (KSB) When this option is present there is an additional display panel in the area below the main control board.
Cleaning, Sanitation and Maintenance This ice system requires three types of maintenance: • Remove the build up of mineral scale from the ice machine ’s water system and sensors. • Sanitize the ice machine ’s water system and the ice storage bin or dispenser.
13. Remove water distributors from ice machine. Inspect distributor for restricted orifice holes. Be sure all holes are full open. 14. Locate ice thickness sensor. Squeeze mounting legs together to release sensor. Wash the metal surfaces of the sensor and the adjustment screw with ice machine scale remover solution.
Remote condenser The condenser fins will need to be cleaned. Push and release the Off button. Wait until the machine stops. Note: Lock out the controller or the ice machine power supply to prevent an unauthorized fan motor restart. If there is imbedded grease, use a commercial coil cleaner to wash out the grease.
What to do before calling for service Reasons the machine might shut itself off: • Lack of water. • Freeze cycle takes too long. • Harvest cycle takes too long. • High discharge temperature. • Controller self test failure. Check the following: 1.
.
SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway, Vernon Hills, IL 60061 800-533-6006 www.scotsman-ice.com 17-3083-03.
An important point after buying a device Scotsman Ice C0522 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Scotsman Ice C0522 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Scotsman Ice C0522 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Scotsman Ice C0522 you will learn all the available features of the product, as well as information on its operation. The information that you get Scotsman Ice C0522 will certainly help you make a decision on the purchase.
If you already are a holder of Scotsman Ice C0522, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Scotsman Ice C0522.
However, one of the most important roles played by the user manual is to help in solving problems with Scotsman Ice C0522. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Scotsman Ice C0522 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center