Instruction/ maintenance manual of the product TSXETG100 Schneider Electric
Go to page of 19
1 Instruction Bulletin 63230-319-211A1 2/2006 ConneXium Ethernet Gate wa y TSXETG100 User’ s Guide Instrucciones en Español: página 19 Instructions en Français: page 39 Anweisungen auf Deutsch : Seite 59 Retain for future use. ENGLISH TABLE OF CONTENTS INTRODUCTION .
ConneXium ™ Ethernet Gateway 63230-319-211A1 Introduction 2/2006 © 2006 Schneider Electric. All Rights R eserved. 2 ENGLISH INTRODUCTION This manual is to be used with a ConneXium ™ ETG100 with firmwa re version 2.0 or higher. For insta llation information, see the installati on guide.
63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Accessing the ETG Over a Network © 2006 Schneider Electric. All Rights Reserved. 3 ENGLISH Additional Resources Documentation and Firmware: Go to www.telemecanique.com, select Products > Products index > Systems and architectures > Connexium.
ConneXium ™ Ethernet Gateway 63230-319-211A1 ETG User Interface OVERVIEW 2/2006 © 2006 Schneider Electric. All Rights R eserved. 4 ENGLISH ETG USER INTERFACE OVERVIEW The ETG ships with seven pre-installed we b pages used for ETG setup and configuration.
63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 5 ENGLISH SETUP To access the Setup web page links, click Setup on the ET G menu b ar . Ethernet and TCP/IP Settings NOTE: After making changes to the Ethernet parameters and clicking Apply, the ETG will reboot.
ConneXium ™ Ethernet Gateway 63230-319-211A1 Setup 2/2006 © 2006 Schneider Electric. All Rights R eserved. 6 ENGLISH Duplicate IP Ad dress Detection While connected to your network, the ETG publishes its IP address.
63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 7 ENGLISH Serial Po rt Action Result 1. From the Setup page, click Serial Port . O pens the Serial Port page. 2. Select your mode, physical interface, transmission mode, baud rate, par ity, and response timeout (see Table 4 on page 7).
ConneXium ™ Ethernet Gateway 63230-319-211A1 Setup 2/2006 © 2006 Schneider Electric. All Rights R eserved. 8 ENGLISH Device List Before you begin, keep in mind the followi ng: For master mode usage of the COM port: • Modbus devices do not have to be defin ed in the De vice List, but it helps you manage your system.
63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 9 ENGLISH Slave Mode Device List Setup Serial port slave mode allo ws serial Modbus master device s to access information from serial slave devices across a TCP/IP network.
ConneXium ™ Ethernet Gateway 63230-319-211A1 Setup 2/2006 © 2006 Schneider Electric. All Rights R eserved. 10 ENGLISH User Accounts ETG users are assigned user names and p asswords. Each user belongs to a group, and each group has access rights to the ETG Web pages assigned by the ETG administrator.
63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 11 ENGLISH Web Page Access Action Result 1.
ConneXium ™ Ethernet Gateway 63230-319-211A1 Setup 2/2006 © 2006 Schneider Electric. All Rights R eserved. 12 ENGLISH Modbus TCP/IP Filtering This function allows the administrator to sp ecify Modbus TCP/IP client devices that have or do not have access to serial slave devi ces connected to the ETG.
63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Setup © 2006 Schneider Electric. All Rights Reserved. 13 ENGLISH SNMP Parameter s The ETG supports SNMP, allowing a network administrator to remotely access an ETG with an SNMP manager an d view the networking status and diagnostics in the MIB2 format.
ConneXium ™ Ethernet Gateway 63230-319-211A1 Diagnostics 2/2006 © 2006 Schneider Electric. All Rights R eserved. 14 ENGLISH DIAGNOSTICS To access the Diagnostics web page links, click Diagnostics on the ETG menu bar . Statistics NOTE: This page will show accumulate d readings since the ETG was last activated.
63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Diagnostics © 2006 Schneider Electric. All Rights Reserved. 15 ENGLISH Interpreting Statistics Statistic Description Ethernet Link Status A status string that represents the speed and duplex setting being used to commun icate with the linking partner.
ConneXium ™ Ethernet Gateway 63230-319-211A1 Diagnostics 2/2006 © 2006 Schneider Electric. All Rights R eserved. 16 ENGLISH Serial Port Frames Sent A counter that increments e ach time a frame is sent. Frames Received A counter that increments each time a f rame is received.
63230-319-211A1 ConneXium ™ Ethernet Gateway 2/2006 Diagnostics © 2006 Schneider Electric. All Rights Reserved. 17 ENGLISH Read Device Registers Action Result 1. From the Diagnostics page, click Read Device Registers . Opens t he Read Device Regi sters page.
ConneXium ™ Ethernet Gateway 63230-319-211A1 Instruction Bulletin 2/2006 ENGLISH Electrical equipment should be installed, opera ted, serv iced, and maintained only by qualified electrical personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
ConneXium ™ Ethernet Gateway 63230-319-211A1 Handbuch 2/2006 DEUTSC H Elektrisches Gerät sollte st ets von qualifizierten Elektr ikern installiert, betrieben und gewartet werden. Schneider Electric übern immt keine Verantwortung für jegliche Konsequenzen, die sich aus der Verw endung dieses Gerãts ergeben könnten.
An important point after buying a device Schneider Electric TSXETG100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Schneider Electric TSXETG100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Schneider Electric TSXETG100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Schneider Electric TSXETG100 you will learn all the available features of the product, as well as information on its operation. The information that you get Schneider Electric TSXETG100 will certainly help you make a decision on the purchase.
If you already are a holder of Schneider Electric TSXETG100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Schneider Electric TSXETG100.
However, one of the most important roles played by the user manual is to help in solving problems with Schneider Electric TSXETG100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Schneider Electric TSXETG100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center