Roll Laminator Service Manual MODEL:RSH-380SL.
3 ~ 3 4 ~ 10 4 ~ 6 6 ~ 7 7 ~ 9 9 ~ 10 11 ~ 11 12 ~ 14 12 ~ 12 13 ~ 13 13 ~ 13 13 ~ 13 13 ~ 13 13 ~ 14 14 ~ 14 15 ~ 16 17 ~ 19 20 ~ 25 26 ~ 29 30 ~ 33 4.Adjustments …………………………………………………………………………………… 5.
Safety Precaution 1. Safety Precautions Failure to comply any of the following safety procedures could result in serious injury. Please read the instructions carefully and keep for future reference. 1. Only a licensed electrician should install wiring and outlet for the laminator.
Note: While repairing: a. Make sure the power plug is unplugged from the power outlet. b. Open both side covers and rear cover. c. Be sure to follow the steps below in order. 2.1 Rollers Not Heating CAUSES: 1. Improper laminating mode. 2. Heating wire is not connected to the main PCB.
2. Blown (burnt) wire fuse (T/Fuse). a. Replace the T/Fuse wire located on the left-hand side. 3. Defective Bi-Metal. a. Replace the Bi-Metal 4. Defective heater. a. Using the multi-meter, test the continuity of the heater. If it fails, replace the heater.
5. Defective Main PCB. a. Replace the PCB Main. 2.2 Rollers Over Heating CAUSES 1. Heat sensor is reversed on the PCB Main. 2. Defective T/Fuse wire. 3. Defective heater. 4. Defective main PCB. MEASURES 1. Wires for lower and upper heat sensors are reversed on the main PCB.
4. Defective Main PCB. a. Replace the PCB Main. 2.3 Rollers Not Running CAUSES 1. No power to the unit. 2. The main switch is close. 3. Opened safety cover. 4. Film is jammed on the rollers. 5. Disconnected motor wire. 6. Defective main motor. 7. Defective main PCB.
4. Film is jammed on the rollers. a. Un-jam the film using a combination of the pressure lever and reverse button. 5. Disconnected motor wire. a. Check the motor wire connection with PCB.
7. Defective main PCB. a. Replace the main PCB. 2.4 No Main Power CAUSES 1. No electricity. 2. Blown main fuse. 3. Disconnected main power wires. 4. Defective transformer. MEASURES 1. No Electricity. a. Double check to insure that you have electricity from your outlet.
4. Transformer is defective a. Replace the transformer. Problem: Straight wave lines across the output. Cause: Excessive front roller pressure. Measure: Loosen the front roller pressure. Problem: Concave waves in the lamination. Cause: Excessive rear (pulling) roller pressure.
Note: While replacing parts: a. Make sure the power plug is unplugged from the power outlet. b. Open both side covers and rear cover. 3.1 Replacing the Right Cover. a. Take out the pressure lever (Figure 1) and four cover screws using Phillips screw driver (Figure 2).
3.4 Replacing the Heaters Note: Cotton or surgical gloves are recommended while handling the heater assembly. a. Disassemble Right and Left Covers (Refer to “ Replacing Right Cover ” and “ Replacing Left Cover ”). b. Take out the heater brackets on each side by loosening screws (Figure 8, 9).
.2 Adjusting front and rear roller s Pressure • Use Screwdriver to adjust the roller pressure: C.W – Increase pressure. C.C.W – Decrease pressure. 1. Using Push-Pull Scale , measure 3 spots as shown on Figure B &C: Front roller should be 5~6 and back rollers should be 6~8.
021LR0001A COVER-L ABS PA-765 UL94 V-0 PANTON 431 125LR4001A HANDLE-TENSION S45C Cu+Ni+Cr 138LR4012A SPRING-TENSION SWP Ф 3.2 12200X022A BEARING-RADIAL 15*28 141LR4033A PLATE-PRESSURE,PULL SPCC 3.0T 138LR4015A SPRING-PRESSURE SWP Ф 2 141LR4032A PLATE-PRESSDURE,LAMI SPCC 3.
141LR4043A FRONT TABLE SAFETY LEVER SPCC 1.5T 013LR4004A SAFETY FRAME SPCC 021LR3024A SAFETY-COVER PC 3.0T 014LR3001B TABLE-FRONT AL6063 133LR3001A ROLLER-LAMI STPG ORG 223LR3001H HEATER ASS'Y FC.
350LR3043A PCB-SUB ASSY FR-4 36600X001A FUSE-BLOCK FB66 LITTLE FUSE TRIAD INC 32500X0008 FUSE-MAIN 65TS AC250V 10A EU,AU,KR,CH,UK,EU(N),BR 32500X0005 FUSE-MAIN 65TS AC250V 20A TW,CUL,JOL,JAP 021LR3018A COVER-R ABS PA-765 UL94 V-0 PANTON 431 138LR4001A SPRING-CUTTER CROSS SWRH Φ 0.
No. Part No. Part Name 1 021LR0001A COVER-L 2 125LR4001A HANDLE-TENSION 3 138LR4012A SPRING-TENSION 4 12200X022A BEARING-RADIAL 5 141LR4033A PLATE-PRESSURE , PULL 6 138LR4015A SPRING-PRESSURE 7 141LR4.
16 7. Wire Diagram 1 2 3 4 5 6 78 A B C D 8 7 6 5 4 3 2 1 D C B A T i tle Numbe r Revision Si ze A2 D a t e : 6 -M ar -2 00 9 S he e t o f Fi le: D: PR O GR A M FI L ES EXAMPLES R SL-3 8 2S CI RS L-3 82 S C I.
1. Wire Main. 6. Wire Power Transformer In 2. Wire Power 7. Wires Power Transformer Output 3. Wire Heater , up 8. Wire Fuse 4. Wire Heater , low 5.
18 SUB PCB Wire Bimetal Wire Up Heater Wire Lo Heater Bimetal(135 ℃ ) Power Cord Fuse Main Motor Wire Sensor.
19 Wire T/Fuse (133 ℃ ) Wire Safety S/W Wire Motor Micro Switch.
An important point after buying a device Royal Sovereign RSH-380SL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Royal Sovereign RSH-380SL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Royal Sovereign RSH-380SL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Royal Sovereign RSH-380SL you will learn all the available features of the product, as well as information on its operation. The information that you get Royal Sovereign RSH-380SL will certainly help you make a decision on the purchase.
If you already are a holder of Royal Sovereign RSH-380SL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Royal Sovereign RSH-380SL.
However, one of the most important roles played by the user manual is to help in solving problems with Royal Sovereign RSH-380SL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Royal Sovereign RSH-380SL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center