Limited Warranty Copyright Rose Elec tronics 1990-2002 . All rights reserved. No part of this manual may be reproduced, stored in a retrieval system, or trans cribed in any form or any means, electroni c or mechanical, including photocopy ing and recording, without the prior written permission of Ro se Electronics.
Table of Contents Contents Disclaimer . .................. ................... .................... .................. ...................... .................. 1 Introduction ........... .................. ..................... .................. ...
Introduction CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 1 Disclaimer W hi le every precaution has been take n in the preparation of this manual, the manufacturer assumes no responsibility for errors or omissions.
2 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Model Number a nd Options The Caretaker Pl u s consists of a switch unit and a sep ar ate wall mou nted pow er adapter. It is availab l e in several mod e ls: 2 to 8 ports , either serial or parallel, and Centronics tyhpe connectors or Db25 type connectors.
FRONT PAN EL DISPL A Y CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 3 Caretaker Pl u s Front Pa nel Display POWER LED is lit whene ver the unit is powered on. ADVANCE and SELECT s w itches a re used to enter the configuration menu, go into diagnostic modes , or clear the buffer.
QUICK SETUP LIST – Serial Units 4 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Serial Se t-Up for PCs 1. Connect your PC t o port 1 on the Caretaker Plus with the proper cable. 2. Connect the po w er adapter to the Ca retaker Plus and turn the Caretaker Plus on.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 5 Caretaker Pl u s Rear Panel – Seri al Model The diagram belo w shows the connector a rrangement for model #CTP-8S. It has nine serial ports. The CTP-4S is similar but it doesn't have ports 5-8.
QUICK SETUP LIST – Parallel Un its 6 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Parallel Set-Up 1. Connect the Care t aker Plus port 0 t o your printe r w ith the correct cable. Connect your computers t o ports 1-8 with th e correct cables.
CABLING CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 7 One of the mos t important steps in i n stalling the Car e taker Plus is to connec t the correct cables. W e have tried to give as much information as possible to specify the correct cable.
8 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL to indicate entry in to configuration mode. Entering configuration mod e will stop data transfer to the sh ared device, and also erase all data in the buffer. No new data can be loaded into the unit w hile in config uration mode.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 9 Configuration M e nu Items In the examples belo w , <ENTER> me ans "press the ENTER key", not "type the characters <ENTER>. Out put f rom the Ca retaker Plus is show n in c ourier type.
10 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Form Feed The form feed, w hen enabled, sends a form feed characte r to the shared de vi ce to eject the last page printe d when a port is disconnected. The factory defaul t is a disabled fo r m feed.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 11 Exit This command is used to exit the conf iguration menu and return the unit to normal ( data transfer) mode . Enter X to the cho ice prompt. A termination message will print, and t he BUSY, DATA, and MODE LEDs w ill retu r n to the state th ey were in bef ore entry to configuration m o de.
12 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Reverse Channe l Data Timeout This command ( on the advanced fe atures menu) determines w hether or not to reset the timeout clock w hen data is received on port O "reverse channel data".
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 13 Configuration Com mands Configuration comma nds allo w changing o f the unit's setup parameters without the Use of a menu. They ma y be used on serial or parallel units. To enable process i ng of configuration comman ds, depress both of the unit's front panel s w itches.
14 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Protocol Comman d This command ch a nges the communication protocol of a given port. If you enter a protocol that blocks communication with the unit or is otherwise undesirable , and you have not used KEEP, you may resto r e the previous format by powering the u n it down and back up.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 15 Parallel Enable Log i c Command This command allows the Caretaker Plus to recognize when a computer t hat is connected to a para l lel port on the Ca retaker Plus is turned off so that the Caretaker Plus will not accep t data from the PC.
OPERATIONS 16 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Initial State Following the succ e ssful completion o f the pow er up t est s, the Care taker Plus turns all the port LEDs off .
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 17 Buffer Characte ri stics The switch ma y h ave a buffer me mory of 16K, 256K, 512K, 1 megabyte, or 2 megabytes. The Caretaker Plus uses an intelligent algorithm to allocate memor y. The buffer is dynam ically allocated which means that any port ca n utilize as much buffer as required.
18 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Timeout The default setting of 20 seconds is sufficient for most applications. Some compu t ers, however, start p r inting and then pause to do some type of calculation or processing an d then resume prin t ing.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 19 Initializa tion String The initialization string is used to reset t h e printer to a de f ined state a t the beginning of each job. In this way the p rinter settings of the last person to print do not af f ect the print settings o f the next person to print.
20 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Power Up Initia l Displa y W he n powering on, the Caretaker Plus goes t hrough a power up self-test which checks the main functi o ns of its electronics. T he leftmost LED labe le d POWER should glow green and the othe r red LEDs should all turn on.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 21 Static Ram R ead/Write Test The next test is for static ram. Sinc e the Caretaker Plus has no static ram, this test is displayed as sho w n in TABLE 6 for consi stency w ith oth er Rose products. Non-volatile Ram Te sts The fourth and f inal power up test is for th e non-volatile memory.
22 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Flow Control Dis p lay Mode (Serial Mode ls Only ) By pressing the ADVANCE switch during normal operation, the LED display is switched to the flow con trol display mode. The MODE LED illuminates to indicate this mode is active.
TROUBLESHOOTING CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 23 Troubleshooting Common Prob l ems and Solutions I. M issing blocks of data on shared device and/or buffe r Overflow error disp lay occurs - seri a l onl y A.
24 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL V. Port(s) do n ot time out A. 'Robus t' X -on/X-off pre sent. Some printers, particularly the HP Las erJet, send X-on codes at timed intervals. Set the 'REVERSE CH ANNEL DATA TIMEOU T' fea ture to Y.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 25 Maintenance an d Repair The exterior surface of the unit may be wiped with a damp cloth to keep it clean. The unit does not conta in any jumpers or se rvi ceable parts insi de. Opening the unit invalidates the warranty except in the case of an authorized memory upgrade or firmware updates.
DIAGNOSTICS 26 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Diagnostic M o des The Caretaker Pl u s has an extensi ve self-test diagnos tic capability. Normally these features are only access ed by a technici an to determine a failure with the unit.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 27 Print Configura ti on/Test Pattern Fu nction Holding both s w itches down at the end of te st 4 causes the unit to print its configuration out to port O, as shown in TABLE 8.
DIAGNOSTICS 28 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL Long Test Wit h out Loopback This group of tes ts are entered by pressing th e select switch only while powering up the unit with the on/of f switch. All equi pment should be disconnected from the unit prior to running this tes t .
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 29 Long Test with L o opback This test is en t ered by pressing the advan ce switch only w hile p owering up the unit with the on/off switch. S pecial loopback conn e ctors should b e connected to each Caretaker Plus port.
A PPENDICES 30 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL A ppendix A : Serial Cabling The diagrams be low show the Caretaker Pl us pinout on the left and all other devices on the right. Read across to find the pinout. Connector types shown belo w refer to the connector on the device, not on the cable.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 31 A ppendix B: Pinou t Specifications Serial M odels DB25 Female Pin Signal Name Acron y m I/O Description 2 T ransm it data TXD Output Serial data.
32 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL A ppendix C: MP1000 Memory Board This memory board provides optional, add-on buffer expansion for the Ca r etaker Plus. Installing this bo ard ex pands the Caretak er Plus buffer from the standard 64K to 256K, 512K, or 1 MB.
CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL 33 Installing the Board Carefully plug the expansion pins of t h e board (the f irst board, if using two) ont o the motherboard's socke ts w here the 64 K chips were removed. Fasten the board down using the two threade d spacers.
34 CARETAKER PLUS INSTALLA TION AND OPERAT IONS MANUAL A ppendix D: Facto ry Defaults Upon receiving the Ca retaker Plus f r om the factory, or rest or ing the unit to default parameters (see 'RE.
.
10707 Stancliff Road Phone: (281) 933- 7673 Houston, Texas 77099 WWW.ROSE .COM.
An important point after buying a device Rose electronic Automatic Switch (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Rose electronic Automatic Switch yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Rose electronic Automatic Switch - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Rose electronic Automatic Switch you will learn all the available features of the product, as well as information on its operation. The information that you get Rose electronic Automatic Switch will certainly help you make a decision on the purchase.
If you already are a holder of Rose electronic Automatic Switch, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Rose electronic Automatic Switch.
However, one of the most important roles played by the user manual is to help in solving problems with Rose electronic Automatic Switch. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Rose electronic Automatic Switch along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center