Instruction/ maintenance manual of the product QFP-80A Renesas
Go to page of 19
H8/3337Y Series, H8/3334 Series, H8/338 Series, H8/330, H8/350 QFP-80A User System Interface Cable (HS3337ECH61H) for E6000 Emulator User’s Manual HS3337ECH61HE(D).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing the E6000 em ulator for the Renesas’s original m icroprocessor H8/300 series. The HS3337ECH61H is a user system interface cable that connects an H8/300 series E600.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
1 Section 1 Configuration CAUTION Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80A package IC socket on the user system. Figure 1 shows the configuration of the HS3337E CH61H user system interface cable for the FP-80A package.
User system IC socket Cable head Screws (M2 x 12 mm) with flat washers Screws (M2 x 8 mm) with flat washers Socket cover (for fastening cable head) To emulator station Cable body Figure 1 HS3337ECH61H.
3 Table 1 lists the HS3337ECH61H com ponents. Please m ake sure you have all of these components when unpacking. Table 1 HS3337ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-80A package 4 Socket cover 1 For installing an FP-80A-packaged MCU 5 Screws (M2.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
6 2.2.4 Fastening Cable Head CAUTION 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Fasten the user system interface cable head to the IC socket fo r an FP-80A package on the user system wit h the four screws (M2.0 x 12 mm ) provided. Each screw should be tightened a little at a time, alt ernating between screws on opposing corners.
2.2.5 Connecting Cable Body to Cabl e Head Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the dime nsions for the recomm ended mount pad (foot print) for the user system with an IC socket for an FP-80A package (IC149-080-017-B5: manufactured by YAM AICHI ELECTRONICS Co., Ltd.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Unit: mm Tolerance: –0.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7. Cable head User system Unit: mm Tolerance: –0.5 mm IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head.
MCU Pin 1 mark User system Screws (M2.0 x 8 mm) with flat washers Socket cover IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.
Section 4 Verifying Operation 1. When using the H8/300 series E6000 emulat or (HS3008EPI60H), turn on the emulat or according to the procedures described in th e H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE).
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MC U.
An important point after buying a device Renesas QFP-80A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Renesas QFP-80A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Renesas QFP-80A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Renesas QFP-80A you will learn all the available features of the product, as well as information on its operation. The information that you get Renesas QFP-80A will certainly help you make a decision on the purchase.
If you already are a holder of Renesas QFP-80A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Renesas QFP-80A.
However, one of the most important roles played by the user manual is to help in solving problems with Renesas QFP-80A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Renesas QFP-80A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center