H8/3297 Series, H8/329 Series QFP-64A User System Interface Cable (HS3297ECH61H) for E6000 Emulator User’s Manual HS3297ECH61HE(C).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing the E6000 em ulator for the Renesas’s original m icroprocessor H8/300 series. The HS3297ECH61H is a user system interface cable that connects an H8/300 series E600.
ii Contents Section 1 Configuration ..................................................................................... 1 Section 2 Connection Procedures ...................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration 1 UTION CA Use an IC149-064-008-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64A package IC socket on the user system. Figure 1 shows the configuration of the HS3297E CH61H user system interface cable for the FP-64A package.
2 Screws (M2.0 x 12 mm) IC socket Cable head User system Socket cover Screws (M2.0 x 8 mm) and flat washers and flat washers (For fastening cable head) Figure 1 HS3297ECH61H User System Interface Cabl.
3 Table 1 lists the HS3297ECH61H com ponents. Please m ake sure you have all of these components when unpacking. Table 1 HS3297ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-64A package 4 Socket cover 1 For installing an FP-64A-packaged MCU 5 Screws (M2.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
2.2.4 Fastening Cable Head 6 UTION CA 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Screws (M2.0 x 12 mm) and flat washers Cable head Pin 1 IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 3 Connecting User System Interface Cable to User .
2.2.5 Connecting Cable Body to Cabl e Head Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the dime nsions for the recomm ended mount pad (foot print) for the user system with an IC socket for an FP-64A package (IC149-064-008-B5: manufactured by YAM AICHI ELECTRONICS Co., Ltd.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7. 9.4 Unit: mm Tolerance: ± 0.5 mm User system IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co.
Section 3 Installing the MCU to the User System 12 UTION CA 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head.
MCU Pin 1 mark User system Socket cover IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) Figure 8 Installing MCU to User System 13.
Section 4 Verifying Operation 1. When using the H8/300 series E6000 emulat or (HS3008EPI60H), turn on the emulat or according to the procedures described in th e H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE).
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MC U.
An important point after buying a device Renesas QFP-64A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Renesas QFP-64A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Renesas QFP-64A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Renesas QFP-64A you will learn all the available features of the product, as well as information on its operation. The information that you get Renesas QFP-64A will certainly help you make a decision on the purchase.
If you already are a holder of Renesas QFP-64A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Renesas QFP-64A.
However, one of the most important roles played by the user manual is to help in solving problems with Renesas QFP-64A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Renesas QFP-64A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center