Instruction/ maintenance manual of the product PRQP0100JE-B Renesas
Go to page of 46
Revision Date: Feb. 28, 2007 Renesas Microcomputer Deve lopment Environment System SuperH ™ Family / SH7146 Series R0E571490CFJ00 Rev.3.00 SH7149 Group PRQP01 00JE-B User System Interface Boa rd Use.
.
1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations with r.
.
I IMPORTANT INFORMATION READ FIRST • READ this user's manual befo re using this emulato r product. • KEEP the user's manual handy for future reference. Do not at tempt to use t he emulator pro duct until you fully understand its mechanism.
II Target User of the Emulator Pr oduct: This emulator product should only be us ed by those who have carefull y read and thoroughly understood the informat ion and restrict ions containe d i n the user's manual. Do not attempt to us e the emulator product until you fu lly understand its mechanism.
III LIMITED WARRANTY Renesas warrants its emulator products to be manufactured in accordance with published specifica tions and free from defects in material and/or workmanship.
IV State Law : Some states do n ot allow the exclu sion or limitatio n of implied warranties or liability for incidental or consequent ial damages, so t he a bove limitati on or exclusion may not appl y to you. This warranty gi ves you specific l egal rights, a nd you may have other rights whi ch may vary from state to state.
V SAFETY PAGE READ FIRST • READ this user's manual befo re using this emulato r product. • KEEP the user's manual handy for future reference.
VI means WARNING or CAUTIO N. Example: CAUTION AG AINST AN ELECT RIC SHOCK means PROHIBITIO N. Example: DISASSEMBLY PROHIBIT ED means A FORCIBLE ACT ION.
VII W ARNING Warnings for AC Power Supply: • If the att ached AC power cable does not fit the receptacle, do not alter the AC power cable and do not plug it forcibly. Failure to comply may cause electric shock and/or fire. • Use an AC power cable which complies with the safety standard of the country.
VIII W ARNING • If you smell a strange odor, hear an unusual sound, or see smoke coming from this product, then disconnect power immediately by unplugging the AC power cable from the outlet. D o not use this as it is because of the danger of electric shock and/or fire.
IX CA UTION Cautions for AC Adapte r: • Use only the AC adapter included in this product package. • The included AC adapter is for this emulator. Do not use it for other product. • The DC plug on the included AC adapter has the below polarity. • The included AC adapter has no power supply switch.
X W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or rem odel the emulator product by yourself for electric shock prevent ion and quality assurance.
i Preface The R0E571490CFJ 00 is a user syst em interface boa rd that connects a user system for the SH7149 PR QP0100JE-B (former code: FP-100AV) package to t he SH7080 E200F emulator (R0E0200F1EMU00 or R0E570800VKK00).
ii.
iii Contents Section 1 Configuration .....................................................................................1 Section 2 Environmental Conditions .................................................................3 Section 3 User In terface Speci fications .
iv.
1 Section 1 Configuration Figure 1 and table 1 show the conf iguration and component s of the user syst em interface board for the PRQP0100J E-B (former code: FP -100AV) package. Please make s ure you have all of these components when unpacking. Board Screws (M2.
2 CA UTION Use a NQPACK 100RB179 socket (manuf actured by Tokyo Eletech Corporation) and a HQPACK100RB 179 (manufactured by Tokyo Eletech Corporation) for the PRQP0100JE- B (former code: FP-100AV) package IC socket and socket cover, respectively, on the user system.
3 Section 2 Environmental Conditions Maintain the condit ions in table 2 w hen using the emulator. Table 2 Environmenta l Conditions Item Specifications Temperature Operating: +10 to +35°C Storage: -10 to +35°C Humidity Operating: 35 to 80% RH, no condensation Storage: 35 to 80% RH, no condensation Vibration Operating: 2.
4.
5 Section 3 User Interface Specifications This user syst em interface board has the function that masks the chip select si gnals (CS0 and CS1), bus reques t signal (BR EQ), and wait input signal (WAIT) depending on the s etting of a switch.
6 Table 3 Setting a Switch (SW1) Switch Setting SW1 No. PRQP0100JE-B (Former Code: FP-100AV) Socket Pin No. Signal Name On Off 1 54 PA9/_WAIT/TCLKD/TXD2 Mask canceled Mask enabled 2 17 PE10/_CS0/TIOC3.
7 Section 4 Connection Procedures 4.1 Connecting User System Int erface Board to User System W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE BOARD is connect ed to or removed from any part. B efore connect ing, make sure that pin 1 on both sides are correct ly aligned.
8 4.1.2 Installing Ca ble Head CA UTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a PR QP0100JE-B (former code: FP-100AV) package on the us er system with pin 1 on the user s ystem interface boa rd, and insert the us er system interface board into the IC socket on the user s ystem, as shown in figure 4.
9 Board Screws (M2.0 x 10 mm) User system IC socket (NQPACK100RB179 manufactured by Tokyo Eletech Corporation) Pin 1 Figure 4 Connecting User System In terface Board to User System.
10 4.2 Connecting User System Interf ace Board to EV-Chip Board W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
11 Board Spacer User system EV-chip unit Connector No. User I/F Connector 1 (CN4) EV-Chip Unit Connector No. Board Connector No. UCN1 UCN2 User I/F Connector 2 (CN5) Figure 5 Connecting User System In.
12 4.3 Recommended Dimensions for Us er System Mount Pad (Footprint) Figure 6 shows the recommended dimensions for the mount pad (footprint ) for the user syst em with an IC s ocket for a PRQP 0100JE-B (former code: FP -100AV) package (NQPAC K100RB179: manufactured by Tokyo Eletech Corporat ion).
13 4.4 Dimensions for External Bus Tr ace Unit, Emulation Memory Unit, EV-Chip Unit, and User S ystem Interface Board The dimensions for the external bus trace unit, em ulation memory unit, EV-c hip unit, and the us er system interface board are shown in figure 7.
14 125.0 90.0 90.0 45.0 5.0 125.0 90.0 110.0 20.0 30.0 60.0 5.0 125.0 90.0 Unit: mm Tolerance: ±0.5 mm External bus trace unit Board Spacer EV-chip unit Pin 1 Emulation memory unit Figure 7 Dimension.
15 4.5 Resulting Dimensions after Conn ecting User System Interface Board The resulting dimensions, after conn ecting the us er system interface board to the user s ystem, are shown in figures 8, 9, and 10. 24.5 55.0 12.5 68.4 30.0 37.5 27.5 29.2 24.5 39.
16 24.5 42.1 12.5 55.5 30.0 37.5 27.5 29.2 24.5 39.19 39.19 24.5 IC socket (NQPACK100RB179 manufactured by Tokyo Eletech Corporation) User system Spacer ( φ 6.
17 24.5 29.2 12.5 42.6 30.0 37.5 27.5 EV-chip unit Spacer ( φ 6.0) IC socket (NQPACK100RB179 manufactured by Tokyo Eletech Corporation) User system Unit: mm Tolerance: ±1.
18.
19 Section 5 Installing the MCU to the User System CA UTION 1. Check t he location of pin 1 before insert ing. 2. Use a Philips-type screwdr iver whose head matches the screw head.
20 MCU (SH7149) Screws (M2.0 x 6 mm) Socket cover Pin 1 User system IC socket (NQPACK100RB179 manufactured by Tokyo Eletech Corporation) Figure 11 Insta lling MCU to User Syst em.
21 Section 6 Verifying Operation 1. Turn on the emulator according to the pro cedures described in the SH -2A, SH-2 E200F Emulator User' s Manual (R0E0200F1EMU 00E or R0E570800EMU00E). 2. The emulator connected to this user syst em interface board supports three kinds of clock sources as t he MCU clock.
22.
23 Section 7 Notice 1. Before connecting any part s or cables, make s ure that pin 1 on the both si des are correctly aligned. 2. Do not apply excessive force to the us er syst em interface board while it is connected to the user sy stem.
24.
SH7149 Group PRQP0100JE-B User System Interface Board User's Manual Publication Date: Rev. 0.50, September 6, 2005 Rev. 3.00, February 28, 2007 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Customer Support Department Global Strategic Communication Div.
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan http://www.renesas.com Refer to " http://www.renesas.com/en/network " for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.
.
SH7149 Group PRQP0100JE -B User System Interface Board User’s Manual.
An important point after buying a device Renesas PRQP0100JE-B (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Renesas PRQP0100JE-B yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Renesas PRQP0100JE-B - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Renesas PRQP0100JE-B you will learn all the available features of the product, as well as information on its operation. The information that you get Renesas PRQP0100JE-B will certainly help you make a decision on the purchase.
If you already are a holder of Renesas PRQP0100JE-B, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Renesas PRQP0100JE-B.
However, one of the most important roles played by the user manual is to help in solving problems with Renesas PRQP0100JE-B. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Renesas PRQP0100JE-B along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center