H8S/2678 Series, H8S/2678R Series, H8S/2668 Series FP-144G/FP-144H User System Interface Cable (HS2678RECH61H) for E6000 Emulator User’s Manual HS2678RECH61HE(C).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system in terface cable (HS2678RECH61H) for the Renesas’s original mi crocomputer H8S/2678 series, H8S/ 2678R series, H8S/2668 series.
ii Contents Section 1 Configuration ...................................................................................... 1 Section 2 Connection Procedures ....................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration CAUTION Use an IC149-144-045-B51 socket (manufactured by YAMAICHI ELECTRONICS C O., Ltd.) for the FP-144G/ FP-144H package IC socket on the user system. Figure 1 shows the configuration of the HS2678REC H61H user system interface cable for the FP-144G/FP-144H package.
2 Table 1 lists the HS2678REC H61H components. Please m ake sure you have all of these components when unpacking. Table 1 HS2678RECH61H Components No. Component Quantity Remarks 1 Cable body 1 2 Cable.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Figure 2 Connecting User System Interf ace Cable to Emulator Station 4.
2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-144G/FP-144H sy stem interface cable head into the IC socket on the user system, as shown i n figure 3. 2.2.4 Fastening Cable Head CAUTION 1.
Fasten the user system interf ace cable head to the IC socket for an FP-144G/FP-144H package on the user system with the four screws (M2 x 12 m m; wi th four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing co rners.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. 8 Cable body Cable head User system unfastening jig Push the unfastening jigs. Removing Figure 4 Fastening Cable Body.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-144G/FP-144H package (IC149-144-045-B51: manufactured by YAMAICHI ELECTRONICS CO.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
Figure 8 Installing MCU to User System 13.
Section 4 Verifying Operation 1. W hen using the E6000 emulator for t he H8S/2678 Series, H8S/2678R Series, H8S/2668 Series, turn on the emulator according to the procedures described in th e E6000 Series Emulator User' s Manual (HS2000EPI61HE). 2.
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU.
An important point after buying a device Renesas H8S/2678R Series (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Renesas H8S/2678R Series yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Renesas H8S/2678R Series - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Renesas H8S/2678R Series you will learn all the available features of the product, as well as information on its operation. The information that you get Renesas H8S/2678R Series will certainly help you make a decision on the purchase.
If you already are a holder of Renesas H8S/2678R Series, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Renesas H8S/2678R Series.
However, one of the most important roles played by the user manual is to help in solving problems with Renesas H8S/2678R Series. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Renesas H8S/2678R Series along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center