Instruction/ maintenance manual of the product H8/3007 Renesas
Go to page of 32
H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group FP-100B/TFP-100B User System Inte rface Cable for E60 00 Emulator Renesas M icrocomput er Developm ent Enviro nment System H8 Family / H8/300 H Series REJ10J0616-0400 Revision Date: A ug.
.
1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations with r.
.
I IMPORTANT INFORMATION READ FIRST • READ this user's ma nual bef ore using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to u se the user sys tem in terface cable until you fully understand its mechanism.
II LIMITED WA RRANTY Renesas warrants its user syst em interfa ce cabl es to be manufactured in accordance with published specific ations and free from defects in material and/or workmanship. Renesas will repair or replace a ny user system interfac e cables determined to be defective in material and/or workmanship.
III State Law : Some states do not allo w the exclusion or limitation of implied warran ties or liability for incidental or c onsequential da mages, so the abo ve limitation or exclusion may not apply to you. This warrant y gives you s pecific legal rights, an d you may ha ve other rights which may va ry from state to state.
IV SAFETY PAGE READ FIRST • READ this user's ma nual bef ore using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to u se the user sys tem in terface cable until you fully understand its mechanism.
V W ARNING Observe the pr ecautions listed b elow. Failure to do so will result in a FIRE H AZARD and will damage the user system and the emul ator product or will result in PERSONAL INJURY. The USER PROGRA M will be LOST. 1. Do not repair or remodel the emul ator product by yourself for e lectric shock pre vention and quality assurance.
VI.
i Preface Thank you for purchasing this user s ystem in terface cable (HS3064BECH61H) for the Re nesas’ original microcomput ers H8/3048 group, H8/3052 group, H8/ 3062 group, H8/3067 group, and H8/3007 group.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User Syst em Interf ace Cable to Emulator Station .
1 Section 1 Configuration CAUTION Use an IC149-100- 054-B51 socket (manuf actured by YAMAICH I ELECTRONICS Co., Ltd.) for the FP-100B/ TFP-100B package IC socket on the user system. Figure 1 shows the configuration of the HS 3064BEC H61H user sys tem interface cable for the FP-100B/ TFP-100B package.
2 Table 1 list s the HS3064BEC H61H components. Pleas e make sure you have all of these components when unpacking. Table 1 HS3064BEC H61H Components No. Component Quantity Remarks 1 Cable body 1 2 Cable head 1 3 IC socket 1 For the FP-100B/TFP-100B package 4 Socket cover 1 For installi ng an FP-100B/TFP -100B-packaged MCU 5 Screws (M2.
3 Section 2 Connection Procedures 2.1 Connecting User System Interfa ce Cable to Emulator Station W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
4 2. After making sure the directi on of the cable body connector is correct, fi rmly insert the cable body connector into the emulator s tation socket, and fas ten the emulator st ation with two C TS screw (M3 x 6 mm) (figure 2).
5 2.2 Connecting User System Int erface Cable to User System W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
6 2.2.3 Inserti ng Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on t he IC socket for an FP -100B/TFP-100B package on the user syst em with pin 1 on the user system interface cable h ead, and ins ert the user system interface cable head into the IC socket on the user s ystem, as shown i n figure 3.
7 Fasten the user s ystem interf ace cable head to the IC socket for an FP -100B/TFP-100B package on the user syst em with the four screws (M2.6 x 12 mm; with four flat was hers) provided. Each screw should be tightened a little at a time, altern ating between screws on opposing corners.
8 2.2.5 Fastening C able Body Connect the cable body t o the cable head. Cable body Cable head User system Remove jig Push the remove jigs. Removing Figure 4 Fastening Cable Body.
9 2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the us er system with an IC s ocket for an FP-100B/T FP-100B package (IC149-100-054-B 51: manufactured by YAMAICHI ELECTRONIC S Co.
10 2.4 Dimensions for User Syst em Interface Cable Head The dimensions for the user s ystem interf ace cable head are shown in figure 6. Unit: mm Tolerance: ±0.
11 2.5 Resulting Dimensions after Conn ecting User System Interface Cable The resulting dimensions, after conn ecting the us er system interface cab le head to the user sys tem, are shown in figure 7. 29.2 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use a Philips-type screwdr iver whose head matches the screw head.
13 MCU Pin 1 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2.6 x 6 mm) with flat washers Socket cover Figure 8 Installing MCU to User System.
14 Section 4 Verifying Operation 1. Start up the emulator according to the pro cedures described in the H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/ 3067 Group, H8/3007 Group E6000 Emulator U ser's Manual (HS3064BEP I61HE).
15 Section 5 Notice 1. Make sure that pin 1 on the user s ystem IC socket i s correctly aligned wit h pin 1 on the cable head before inserting t h e cable head into the us er system IC s ocket. 2. The dimensions of the recommended mount pad for t he user system IC s ocket are different from those of the MCU .
16 6. The P1 jumper is us ed for testing. A j umper pin is insert ed in pin 1 side. Do not remove the inserted jumper pin. CAUTION Insert the jumper pin in pin 3 side for P4 jumper when pin 10 of the MC U is not used as RESO . Otherwise the user system interface cable, the emul ator product, and the user system will be damaged.
H8/3048 Group, H8/3052 Group, H8/3062 Group, H8/3067 Group, H8/3007 Group FP-100B/TFP-100B User System Interface Cable for E6000 Emulator User's Manual Publication Date: Rev.3.00, March, 2003 Rev.4.00, August 20, 2008 Published by: Sales Strategic Planning Div.
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan http://www.renesas.com Refer to " http://www.renesas.com/en/network " for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.
.
H8/3048 Group, H8/3052 Gro up, H8/3062 Group, H8/3067 Gro up, H8/3007 Group FP-100B/ TFP-100 B User System Interface Cable for E6000 Emulator User’s Manual.
An important point after buying a device Renesas H8/3007 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Renesas H8/3007 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Renesas H8/3007 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Renesas H8/3007 you will learn all the available features of the product, as well as information on its operation. The information that you get Renesas H8/3007 will certainly help you make a decision on the purchase.
If you already are a holder of Renesas H8/3007, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Renesas H8/3007.
However, one of the most important roles played by the user manual is to help in solving problems with Renesas H8/3007. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Renesas H8/3007 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center