Instruction/ maintenance manual of the product FP-100B Renesas
Go to page of 20
H8/2318 Series FP-100B/TFP-100B User System Interface Cable (HS2318ECH61H) for E6000 Emulator User’s Manual Rev. 2.0 4/1/03 Renesas Technology Corp. HS2318ECH61HE(B).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system interface cable (HS2318ECH61H) for the Renesas’s original mi crocomputer H8/2318 series. The HS2318ECH61H is a user system interface cable that co.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B/TFP- 100B package IC socket on the user system. Figure 1 shows the configuration of the HS2318E CH61H user system interface cable for the FP-100B/TFP-100B package.
2 Table 1 lists t he HS2318ECH61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2318ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP-100B/TFP-100B package 4 Socket cover 1 For installing an FP-100B/TFP-100B-packaged MCU 5 Screws (M2.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Figure 2 Connecting User System Int erface Cable to Emulator Station 4.
2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pi n 1 on both sides are correctly aligned.
6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100B /TFP-100B package on the user system with pin 1 on the user system interface cable h ead, and insert the user system interface cable head into the IC socket on the user system , as shown in figure 3.
Fasten the user system interf ace cable head to the IC socket for an FP-100B/TFP-100B package on the user system wit h the four screws (M2.6 x 12 m m ; with four flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing co rners.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jigs. Removing User system Figure 4 Fastening Cable Body 8.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-100B/TFP-100B package (IC 149-100-054-B51: manufact ured by YAMAICHI ELECTRONICS Co.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system inte rface cable head are shown in figure 6. Unit: mm Tolerance: ±0.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
Figure 8 Installing MCU to User System 13.
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2338 series, turn on the emulator according to the procedures described in the H8S Series E6000 Em ulator User’s Manual (HS2000EPI61HE).
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU.
Figure 11 P1 Short Connector 16.
An important point after buying a device Renesas FP-100B (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Renesas FP-100B yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Renesas FP-100B - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Renesas FP-100B you will learn all the available features of the product, as well as information on its operation. The information that you get Renesas FP-100B will certainly help you make a decision on the purchase.
If you already are a holder of Renesas FP-100B, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Renesas FP-100B.
However, one of the most important roles played by the user manual is to help in solving problems with Renesas FP-100B. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Renesas FP-100B along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center