Instruction/ maintenance manual of the product P121RC-NG Regency
Go to page of 40
STYLE MODEL See Thru P121-NG P121-LPG Left Corner P121LC-NG P121LC-LPG Right Corner P121RC-NG P121RC-LPG Pier P131-NG P131-LPG 02/16/06 Zero Clearance Room FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appli- ance Do not touch any electrical switch: do not use any phone in your building.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 2 To the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P121/P121LC/P121RC/ P131 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 3 T ABLE OF CONTENTS Operating Instructions Operating Instructions ............................................... 2 9 Lighting Procedure ........................................
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 4 SAFETY LABEL This is a copy of the label that accompanies each REGENCY P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace. We have printed a copy of the contents here for your review.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 5 INST ALLA TION INST ALLA TI ON CHECKLIST 1 ) Locate appliance a ) Room location, page 8. b) Clearances to Combustibles, page 9. c ) Mantle Clearances, page 9. d ) Framing & Finishing Requirements, page 10.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 6 INST ALLA TION SPECIFICA TIONS P121 - See Thru P131 - Pier Note: These units are non-load bearing.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 7 P121LC - Left Corner Unit P121RC - Right Corner Unit INST ALLA TION Note: These units are non-load bearing.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 8 LOCA TING YOUR GAS FIREPLACE 1 ) When selecting a location for your stove, ensure that the clearances are met as outlined on page 9. 2 ) Provide adequate clearances for servic- ing.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 9 INST ALLA TION COMBUSTIBLE MANTELS CLEARANCES The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams on page 8): WARNING: Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 10 B C A FRAMING AND FINISHING CAUTION: The unit does not have to be completely enclosed in a chase. The clearance on top of the unit is 0" to the standoffs so combustible building materials can be laid directly on top of the standoffs.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 11 FLUEING INTRODUCTION The P121/P121LC/P121RC/P131 uses the "balanced flue" technology Co Axial system.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 12 INST ALLA TION EXTERIOR FLUE TERMINA TION LOCA TIONS Minimum clearances required for balanced flue terminals or the flue ter.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 13 FLUEING ARRANGEMENT - HORIZONT A L TERMINA TIONS Regency Direct Vent System (Flex) Horizontal Terminations Only These fluein.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 14 Simpson Dura-Vent Direct Vent GS SIMPSON DURA-VENT FLUEING COMPONENTS LIST All Simpson Dura-Vent components are available directly from Regency.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 15 INST ALLA TION FLUEING ARRANGEMENTS - HORIZONT A L TERMINA TIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG) The diagram below shows examples of horizontal termination arrangements using one, two, or three 90 o elbows (two 45 o elbows equal one 90 o elbow).
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 16 INST ALLA TION Diagram 3 Horizontal Flueing with Two (2) 90 o Elbows Option V H + H1 A ) 1 ' (305mm) Minimum 2' (610mm) Maximum B ) 2 ' (610mm) Minimum 5' (1.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 17 INST ALLA TION FLUEING ARRANGEMENTS - VERTICAL TERMINA TIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG) Flue must be supported at offsets Maintain clearances to combustibles as listed on page 9.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 18 INST ALLA TION Vertical Flueing with Two (2) 90 o Elbows Option V H A ) 1 ' (305mm) Minimum 4' (1.22m) Maximum B ) 2 ' (610mm) Minimum 6' (1.86m) Maximum C) 3' (914mm) Minimum 9' (2.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 19 INST ALLA TION HORIZONT A L INST ALLA TIONS Install the flue system according to the manufacturer's instructions included with the components. 1) Set the unit in its desired location.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 20 Diagram 3 Diagram 5 Diagram 1 Diagram 2 Note: Apply sealant "Mill-Pac" to inner pipe and high temperature sili- cone sealant to outer pipe on eve- ry twist-lock joint.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 21 INST ALLA TION inside each other and can be adjusted for 2 x 4 or 2 x 6 walls.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 22 CONVERSION KIT FROM NG TO LPG MODEL #730-969 FOR P121/P121LC/P121RC/P131 USING SIT 820 NOV A GAS VAL VE THIS CONVERSION MUST BE DONE BY A AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 6) Pull off the pilot cap to expose the pilot orifice.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 23 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 3.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 24 INST ALLA TION LOG INST ALLA TION Read the instructions below carefully and refer to the dia- grams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 25 INST ALLA TION 327 327 Repeat step 3 on the opposite side of the burner. Place Log 329 onto pin. 329 329 328 328 328 326 329 Grate Post 5) Place Log 3 29 on the middle left side of the burner.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 26 GLASS DOOR REMOV A L 1 ) Remove the 8 screws that secure the glass door. INST ALLA TION 2 ) Pull the door slightly out on an angle and then lift up and pull completely out.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 27 Option 1: REMOTE CONTROL Can be used with Option 2 or 3 but not both. Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 28 WIRING DIAGRAM Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 29 OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 30 MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacu- uming at least once a year.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 31 MAINTENANCE 2) Remove the Cap, and shine a flashlight down the Flue. Remove any bird nests, or other foreign material.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 32 1 2) Lift the entire assembly out. 8 ) Remove the Side Base Brick Panels and finally the Long Base Brick Panels. MAINTENANCE Remove Left & Right Side Base Brick Panels Remove the 2 Long Base Brick Panels 9 ) Disconnect the inlet gas line.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 33 P ARTS LIST P121 (SEE THRU) MAIN ASSEMBL Y Part # Description Part # D escription Part # Description 1 ) 360-528 Door Assy F.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 34 P ARTS LIST P131 (PIER) MAIN ASSEMBL Y Part # Description Pa rt # De scription Part # Description 1 ) 360-528 Door Assy Fron.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 35 P121RC (RIGHT CORNER) MAIN ASSEMBL Y Part # Description Part # D escription Part # Description P ARTS LIST 1 ) 360-528 Door .
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 36 P ARTS LIST P121LC (LEFT CORNER) MAIN ASSEMBL Y Part # Description Pa rt # De scription Part # Description 1 ) 360-528 Door .
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 37 P121/P121LC/P121RC/P131 BURNER ASSEMBL Y & LOG SET Part # Description 360-930 L og Se t 41) 904-326 Front Right Log 42) 904-327 Fr ont Left Log 43) 904-328 Middle Left Log 44) 904-329 Middle Right Log 360-574/P Valve Assembly 5 6) 360-378/P Valve S.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 38 _____________________________________________________________________________________ ______________________________________.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 39 W ARRANTY Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.
Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved..
An important point after buying a device Regency P121RC-NG (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Regency P121RC-NG yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Regency P121RC-NG - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Regency P121RC-NG you will learn all the available features of the product, as well as information on its operation. The information that you get Regency P121RC-NG will certainly help you make a decision on the purchase.
If you already are a holder of Regency P121RC-NG, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Regency P121RC-NG.
However, one of the most important roles played by the user manual is to help in solving problems with Regency P121RC-NG. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Regency P121RC-NG along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center