THE IMPORT ANT : READ AND SA VE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER BOILING W A TER DISPENSER INST ALLA TION & OPERA TING INSTRUCTIONS.
Thank you for choosing a quality Redring product manufactured b y Applied Energy Products Limited, Peterborough, U.K. 2 Contents Page Installation Instructions Important notes ................................................ ..........................
3 What the installer will need ● A 13 Amp fused double pole isolating switch with a minimum contact gap of 3mm in each pole. ● Suitable length of 1.0mm 2 three core multi strand PVC insulated mains cable that complies with BS6500. ● Suitable lengths of 15mm copper pipe.
4 Installing the mains supply If a mains supply is not already available. ● Install a 13 Amp fused double pole isolating switch with a minimum contact gap of 3mm in each pole adjacent to where the unit will be fixed. Removing the front cover ● Remove the screws from the bottom and top edge of the unit (Fig.
5 Fig. 5b Fig. 4 Fig. 5a.
6 Fixing the unit on the wall ● Use the wall mounting bracket supplied and the two lower fixing holes. ● An extra top fixing point is available by temporarily removing the condenser assembly .
7 Operating Instructions General Product Description The SB 2 is a wall mounted, self calibrating and self filling boiling water heater . It can be used for making cups of tea or coffee and even soups and hot snacks. A special condenser traps steam and returns droplets to the tank, minimising waste and saving energy .
Please Note: ● The SB 2 can take several minutes to reach the required temperature, dep ending on usage and tank capacity . ● T o avoid energy wastage, the SB 2 will automatically reduce the temperature by 10 º C if the unit is not used for more than 60 minutes.
9 T rouble shooting SELF HELP (See T able 1) – If the SB 2 is unsatisfactory, then make the following checks before calling out the contractor . Any one of these adjustments could restore the performance. T able 1 a) TEMPERA TURE READY light is not on This is normal: The water has not reached the set temperature.
10 SB 2 heat up times T able 3 Professional Service (see table 2) If the SELF HELP checks do not cover the symptom, you should seek professional help. The following additional checklist is provided for the benefit of the qualified engineer . WARNING: SWITCH OFF THE ELECTRICITY A T THE ISOLA TING SWITCH BEFORE REMOVING THE COVER TO MAKE CHECKS.
11 APPLIED ENERGY PRODUCTS AFTER SALES SERVICE W e offer a technical service on the telephone to contractors and other customers seeking advice. RING 08709 000430 Some parts can be supplied using a credit card.
Guarantee W e, Applied Energy Products Ltd., guarantee that should this SB 2 unit prove to be defective by reason of faulty workmanship or material within 24 months (outside of U.
An important point after buying a device Redring CD-RW901SL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Redring CD-RW901SL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Redring CD-RW901SL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Redring CD-RW901SL you will learn all the available features of the product, as well as information on its operation. The information that you get Redring CD-RW901SL will certainly help you make a decision on the purchase.
If you already are a holder of Redring CD-RW901SL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Redring CD-RW901SL.
However, one of the most important roles played by the user manual is to help in solving problems with Redring CD-RW901SL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Redring CD-RW901SL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center