Instruction/ maintenance manual of the product 10-175UL RCI
Go to page of 8
10-175UL Access Control Power Supply/Charger Installation and Specifications Manual ® 10-175UL Power Supply INST ALLA TION.
Over view The 10-175UL is a power limited power supply/charger that will convert 115V AC / 60Hz input, into two individually PTC protected 12VDC or 24VDC output, (see specifications). They are intended for use in applications requiring UL Listing for Access Control (UL294) and applications requiring an interface with Fire Alarm Control Panels.
Installation Instructions The 10-175UL should be installed in accordance with article 760 of The National Electrical Code or NFP A 72 as well as all applicable Local Codes. See T erminal Identification Chart on page 4 for a description of each terminal function.
T er minal / Switch Identifcation: T erminal Legend Function/Description TRGI & TRG2 These input terminals are designed to connect to the normally closed outputs of an access control or fire alarm relay . These terminals control [LOCK+], and [STRIKE+], as well as 10-175UL output relay contacts [N.
10-175UL SW1 VR1 + BA T -- AC AC LOCK + STRIKE + COM - AUX + FACP AUX - NC NO C TRG1 TRG2 SW1 CLOSED -24V OPEN - 12V NC C NO AC FAIL XFMR Green Lead (ground) Stand-by Battery (optional) Constant output (not affected by trigger) Switched DC output (trigger control) Black Lead White Lead 115VAC input 60 Hz, .
4.50" [114.3mm] 4.50" [114.3mm] 4.50" [114.3mm] 1.25" [31.8mm] 2.13" [54.0mm] 2.25" [57.2mm] 3.38" [85.7mm] 3.38" [85.7mm] 1.25" [31.8mm] 4.50" [114.3mm] 4.50" [114.3mm] 1.50" [38.1mm] 4.50" [114.
FIG 3. T ypical Single Mag lock or door strike installation with fire alarm tie-in using trigger controlled output. FIG 4. T ypical dual mag lock installation with fire alarm tie- in using trigger controlled outputs.
IS10-1 7 5UL ECN07 00 1 2 R04/0 7 T r oubleshooting Guide Problem Solution - Check AC and DC LED’ s on power supply board. Both should be on for proper operation AC ON –GREEN, T rouble: Normal – AMBER, DC ON - RED. - If LED’ s are not on, check AC power .
An important point after buying a device RCI 10-175UL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought RCI 10-175UL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data RCI 10-175UL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, RCI 10-175UL you will learn all the available features of the product, as well as information on its operation. The information that you get RCI 10-175UL will certainly help you make a decision on the purchase.
If you already are a holder of RCI 10-175UL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime RCI 10-175UL.
However, one of the most important roles played by the user manual is to help in solving problems with RCI 10-175UL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device RCI 10-175UL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center