Instruction/ maintenance manual of the product VCC-5775P Proxima ASA
Go to page of 20
INSTRUCTION MANUAL BEDIENUNGSANLEITUNG MANUEL D’INSTRUCTIONS VCC-5775P COLOUR CCD camera CCD-Farbkamera Caméra CCD COULEUR CCD About this manual Befor e installin g and using the camer a, please read this manual carefully. Be sure to keep it handy for later reference.
Depending on the conditions of use, installation and environment, please be sure to make the appropriate settings and adjustments. If you need help with installation and/or settings, please consult your dealer. CONTENTS PRECAUTIONS ...................
FEATURES • Built-in interline transfer method 1/3" CCD, approx. 470,000 picture elements • Low smear, anti-blooming, low lag, no burning and no geometric distortion using the CCD solid state image device.
PRECAUTIONS In case of problem Do not use the camera if smoke or a strange odour comes from the unit, or if it seems not to function correctly. Disconnect the power cord immediately, and consult your dealer (or a Sanyo Authorized Service Centre). Do not open or modify Do not open the cabinet, as it may be dangerous and cause damage to the unit.
PRECAUTIONS Protect from high temperatures Do not install close to stoves, or other heat generating devices, such as spotlights, etc., or where it could be subject to direct sunlight, as that could cause deformation, discoloration or other damages.
PARTS NAMES 1 Camera mounting screw hole CAUTION: When installing the camera, select a location that can support the total weight of the camera and accessories.
PARTS NAMES 7 Flange-back lock screw 8 CS mount ring 9 Lens mount cap The cap is installed to protect the lens mount section. Remove the lens mount cap before installing a lens. F Video output connector (VIDEO OUT: BNC type) Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector.
MOUNTING THE LENS Please use a DC type auto-iris lens (sold separately). Checking the lens mount Do not use lense with a length L more than 5 mm. If not, that may damage the camera and prevent proper installation. 1 Remove the lens mount cap from the camera.
MOUNTING THE LENS Pin layout 1 Brake coil (–) 2 Brake coil (+) 3 Drive coil (+) 4 Drive coil (–) Rewiring the lens cable in the lens iris plug 1 Prepare the lens cable. Cut t he c a ble at the plug, t hen r emove approx. 8 mm of the cable shea t h and stri p a b out 2 mm from e a ch wi re.
CONNECTIONS Basic connection for monitoring or recording (Video signal connections) : VIDEO IN : VIDEO OUT AC 24 V connection DC 12 V connection Fig. 1 Fig. 2 + – + DC12V – Push to insert the cable. Note: The polarities for the 24 V AC and the 12 V DC input connectors are indicated on the rating label found on the unit back panel.
CONNECTIONS The peripheral devices (VCR, monitor, lens, etc.) and cables are sold separately. 1 Make the video signal connection between the camera and the monitor or timelapse VCR. 2 Power supply choices • Use a commercially available 24 V AC adaptor.
FLANGE-BACK ADJUSTMENT If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of focus ( in particular when using auto-iris power zoom lenses, sold separately ). If that is the case, adjust the flange-back position as described below.
SETTINGS Line phase adjustment When using a camera switcher to connect 2 cameras or more to one monitor, there may be a vertical roll of the images when switched. In such a case, set as described below. 1 Set the Sync switch to the L-L position. 2 Switch the display on the monitor from camera 1 to camera 2.
SETTINGS Lens iris adjustment If using a DC type auto-iris lens, you will need to set the LEVEL volume when shooting in the conditions described below. Counterclockwise: To decrease the brightness Clockwise: To increase the brightness • If shooting simultaneously in a dark room and through a bright window.
SETTINGS EI (Electronic iris) function setting Under normal conditions, set the EI switch to the EI OFF position and use an auto-iris lens. However, if you have a manual lens or fixed iris lens, set the lens aperture to the shortest F stop and set the EI switch to the EI ON position.
TROUBLESHOOTING Before tak ing t he camer a for r epairs, p lease c hec k below to make su re that t he ca mera is used cor rectly. If it still does not perform correctl y , p lease cons u lt you r deale r or a Sany o Authori zed Ser v i c e Ce ntre.
SPECIFICATIONS Scanning system: PAL standard (625 TV lines, 25 frames/sec.) Interlace: 2:1 interlace Image device: 1/3 in ch s olid s tate image device C C D Picture elements: 798 (H) x 584 (V) Effect.
SPECIFICATIONS Dimensions: mm Features and specifications are subject to change without prior notice or obligations. 51 63 68 (1) L53V2/ XE (VCC -5775P ) GB 2000, 7 , 11 English 17.
ACCESSORIES 12 1 C mount adaptor (5 mm) ........................ 1 pc. The C mount adaptor must be used to be able to install a C mount lens on the camera.
1AC6P1P2347-- L53V2/XE(0700KP-DSP) Sanyo Electric Co, Ltd. Printed in Japan L53V2/ X E (VCC -5775P) GB 2 000, 7, 11.
An important point after buying a device Proxima ASA VCC-5775P (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Proxima ASA VCC-5775P yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Proxima ASA VCC-5775P - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Proxima ASA VCC-5775P you will learn all the available features of the product, as well as information on its operation. The information that you get Proxima ASA VCC-5775P will certainly help you make a decision on the purchase.
If you already are a holder of Proxima ASA VCC-5775P, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Proxima ASA VCC-5775P.
However, one of the most important roles played by the user manual is to help in solving problems with Proxima ASA VCC-5775P. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Proxima ASA VCC-5775P along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center