Instruction/ maintenance manual of the product PFSG51030 ProForm
Go to page of 20
USER’S MANUAL QUESTIONS? If you have questions, or if there are missing parts, we will guar- antee complete satisfaction through direct assistance from our factory . TO A VOID DELA YS, PLEASE CALL DIRECT TO OUR T OLL- FREE CUSTOMER HOT LINE. The technicians on our cus- tomer hot line will provide imme- diate assistance, free of charge.
2 PROFORM is a registered trademark of ICON Health & Fitness, Inc. Posting the W arning Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions .
3 W ARNING: T o reduce the risk of drowning, electric shock, or serious injury , read the fol- lowing important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure that all users of the hydrotherapy spa are adequately informed of all precautions.
4 20. DANGER—Risk of electric shock. Keep all electrical appliances such as radios, tele- phones, televisions, and lights at least five feet away from the water . 21. A wire connector is provided on the electron- ics pack of the hydrotherapy spa to connect a minimum No.
5 W ARNING: Read all instructions before using the hydrotherapy spa. ICON assumes no responsibility for personal injury or property damage sustained by or through the use of this product. SA VE THESE INSTRUCTIONS 35. W ARNING: The spa jets produce a stream of water with relatively high pressure.
6 Congratulations for selecting the new PROFORM ® ORBIT hydrotherapy spa. The innovative ORBIT spa allows you to enjoy all the benefits of hydrotherapy in the comfort and privacy of your home. Hydrotherapy is a proven method for soothing tired muscles after exercise or for relieving the stress of a busy life.
7 There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa.
8 Before beginning assembly , carefully read the following information and instructions: • Place all parts in a cleared area and remove the packing materials from the spa shell. Do not dis- pose of the packing materials until assembly is completed and the spa is operating.
9 4. Place the Spa Cover (18) over the spa. Make sure that the Spa Cover is properly centered. Snap a Buckle (2) onto each of the four latches on the Spa Cover (18). See the inset drawing. Position one of the Buckles (2) on one of the Long Panels (38), and hold the Buckle in place so that the strap on the Spa Cover (18) is tight.
10 The hydrotherapy spa is designed to seat two adults. The spa holds approximately 200 gallons of water and offers a heating system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment.
SP A OPERA TION Refer to the diagram above. The function of each component is explained below: The seven uni-directional jets (A) are located on both sides of the spa. Three jets focus a water mas- sage on your upper back, and the remaining jets pro- vide a foot massage.
12 Using the Controls Refer to the diagram above. The function of each control is explained below: Pump Button: T urns the spa jets on and off. If the button is pressed once, the spa jets will run at low speed, providing gentle hydrotherapy . If the button is pressed again, the jets will run at high speed, provid- ing more intense hydrotherapy .
13 The hydrotherapy spa is designed to provide years of enjoyment. Please follow the guidelines below to properly maintain your spa. MAINTENANCE SCHEDULE Daily • Check the water level and refill the spa to the level shown in step 3 on page 9. • Check the pH balance and sanitizer level.
14 Severe problems can occur when the pH balance is not maintained within this range. If the pH level exceeds 7.8, dissolved minerals can build up and clog the plumbing in the spa jet unit. If the pH level falls below 7.2, the acid level in the water will begin to cor- rode the metal parts in the spa jet unit.
15 T o drain the hydrotherapy spa, follow the steps below: 1. Using the console, adjust the temperature to the lowest setting. 2. Shut off the power to the spa, at the circuit breaker or GFCI. 3. Remove the access panel from the spa (see A TT ACHING AND REMOVING THE ACCESS P ANEL on page 14).
16 1. SYMPTOM: THE SP A WILL NOT OPERA TE a. Check to see if the GFCI breaker is tripped or was not turned on. Reset the GFCI breaker . 2. SYMPTOM: THE CIRCUIT BREAKER OR THE GFCI TRIPS WHILE THE SP A IS OPERA TING a. Reset the circuit breaker or the GFCI.
17 3. SYMPTOM: THE PUMP HUMS a. The filter may be dirty or damaged. Remove the filter from the filter housing and clean or replace the filter (see page 16). b. The pump may have a foreign object stuck in the impeller . Contact our customer service department.
18 1 8 Buckle Screw 2 4 Buckle 3 4 Corner Panel 4 8 1/4” W asher 5 4 Rubber Insulator 6 1 Blue Lens 7 1 W aterfall Knob 8 2 2” O-ring 9 2 Removable Collar 10 2 Filter Cartridge 1 1 2 Hinge Pin 12 .
19 Exploded Drawing—Model No. PFSG51030 R0203A 1 2 2 6 17 18 19 25 26 27 30 36* 20 24 34 33 32 21 22 10 23 4 28 5 13* 29 12 8 15 31 35 35 35 35 35 3 3 3 11 11 7 12 14* 12 12 16 16 9 9 40.
Part No. 195109 R0203A Printed in USA © 2003 ICON Health & Fitness, Inc. T o order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday , 8 a.m. until 5 p.m. Central T ime (excluding holidays).
An important point after buying a device ProForm PFSG51030 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ProForm PFSG51030 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ProForm PFSG51030 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ProForm PFSG51030 you will learn all the available features of the product, as well as information on its operation. The information that you get ProForm PFSG51030 will certainly help you make a decision on the purchase.
If you already are a holder of ProForm PFSG51030, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ProForm PFSG51030.
However, one of the most important roles played by the user manual is to help in solving problems with ProForm PFSG51030. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ProForm PFSG51030 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center