PDP-504CMX Plasma Display Panel RS-232C Commands C OMMAND P ROTOCOL M ANUAL Manual Version 1.00 November 3, 2004 Pioneer Corporation Pioneer Electronics (USA) Inc.
This manual is copyrighted with all rights reserve d. No part of this document may be repri nted, produced, translated or utilized in any form or by any means now known or her eafter invented includi .
1 RS-232C Adjustment Mode 5.5 RS-232C Adjustment Mode This display has a RS-232C terminal. It is possible to use a PC to make various adjustments and settings. 5.5.1 About the RS-232C Adjustment Mode 1) Adjustments in the RS-232C adjustment mode: • The adjustments are written to the same memory area as for the integrator mode (refer to section 5.
2 RS-232C Adjustment Mode 5.5.2 Interface 1) Connector D-sub 9 pins (male) 2) Pin layout 3) Baud Rate 9600 bps (standard) (switch-able to 1200, 2400, 4800, 19200, 38400 bps) Note The baud rate of this display should be set to match the baud rate of the PC.
3 RS-232C Adjustment Mode 5.5.3 ID Assignment After connecting to the PC, an ID is assigned. The ID is assigned from the PC. Commands: <IDC> (ID CLEAR) ........ Clears the assigned ID <IDS> (ID SET) ............. Assigns an ID IDS is only effective when an ID is not assigned.
4 5.5.4 Combination Connection When performing control and adjustment, it is convenient to connect several sets to one PC. By performing a combination connection and assigning IDs to the sets, it is possible to control and adjust several sets at the same time or separately.
5 Under the connection conditions shown below, operation using a combination cable is assured up to 16 sets. Conditions: 1 Length of RS-232C cable connecting PC to PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S: .
6 RS-232C Adjustment Mode 5.5.5 List of RS-232C Commands How to read this Table • RS-232C adjustment validity : Indicates whether or not the RS-232C adjustment mode can be used. • Normal validity : Indicates whether or not the normal-operation mode can be used.
7 RS-232C Adjustment Mode CTR CTI: ### Displays the current CTI setting. ¶ CTRS00 CTI: OFF Sets CTI to OFF. ‡ CTRS01 CTI: ON Sets CTI to ON. ‡ [D] DIN Turns OFF the OSD display. ‡‡ DIY OSD: ON Turns ON the OSD display. ‡‡ DNR DNR: ###### Displays the current DNR setting.
8 RS-232C Adjustment Mode GRA GRADATION: ####### Displays the current GRADATION setting ¶ GRAS01 GRADATION: GAMMA 2.0 Sets GRADATION to ‘ GAMMA 2.0 ’ . ‡ GRAS02 GRADATION: GAMMA 1.8 Sets GRADATION to ‘ GAMMA 1.8 ’ . ‡ GRAS03 GRADATION: GAMMA 2.
9 RS-232C Adjustment Mode MIR MIRROR MODE: ### Displays the current MIRROR MODE setting. ¶ MIRS00 MIRROR MODE: OFF Turns the MIRROR MODE OFF (normal display). ‡ MIRS01 MIRROR MODE: X Sets the MIRROR MODE to left-right reversal. ‡ MIRS02 MIRROR MODE: Y Sets the MIRROR MODE to up-down reversal.
10 RS-232C Adjustment Mode SSI ######### Displays the current sub screen input function. ¶¶ SSIS01 INPUT1(SUB) Switches the sub screen to INPUT1. ‡‡ SSIS02 INPUT2(SUB) Switches the sub screen to INPUT2. ‡‡ SSIS03 INPUT3(SUB) Switches the sub screen to INPUT3.
11 RS-232C Adjustment Mode 5.5.6 GET Commands What are GET commands? • They are commands for outputting TXD such as adjustment data from the internal microcomputer of the plasma display to a PC. • Adjustment data and the like is output in ASCII code.
12 RS-232C Adjustment Mode 2) <GPI> (GET PICTURE DATA: Gets integrator/PICTURE data.) Order Data contents Size Remarks 1 CONTRAST 3 Byte # 2 BRIGHTNESS 3 Byte # 3 C. DETAIL R (RED) 3 Byte # 4 C. DETAIL Y (YELLOW) 3 Byte # 5 C. DETAIL G (GREEN) 3 Byte # 6 C.
13 RS-232C Adjustment Mode 5) <GSS> (GET STATUS SETUP: Gets menu and integrator SETUP data.) Order Data contents Size Output Remarks 1 GRADATION 1 Byte 1: GAMMA 2.0 2: GAMMA 1.8 # 3: GAMMA 2.2 4: DRE MID 5: DRE HIGH 6: DRE LOW 7: HIGH CNT. 2 BRT.
14 RS-232C Adjustment Mode 6) <GSO> (GET STATUS OPTION: Gets menu and integrator OPTION data.) Order Data contents Size Output Remarks 1 ENERGY SAVE 1 Byte 1: STANDARD 2: MODE 1 3: MODE 2 4: MOD.
RS-232C Adjustment Mode Check Sum This is data to which 2-Byte ASCII code is added to a data group returned by a GET command. PC side STX ID GET command ETX 02 (hex) 2 Byte 3 By te 03 (hex) Set side STX GET command Data Check Sum ETX 02 (hex) 3 Byte *Byte 2 Byte 03 (hex) A det ailed example will be given below .
PDP-504CMX RS-232C Command Protocol Manual Pioneer Electronics (USA) Inc. Industrial Solutions Business Group 2265 East 220 th Street Long Beach, California 90810 United States of America (310) 952-2000 http://www.
An important point after buying a device Pioneer PDP-504CMX (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pioneer PDP-504CMX yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pioneer PDP-504CMX - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pioneer PDP-504CMX you will learn all the available features of the product, as well as information on its operation. The information that you get Pioneer PDP-504CMX will certainly help you make a decision on the purchase.
If you already are a holder of Pioneer PDP-504CMX, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pioneer PDP-504CMX.
However, one of the most important roles played by the user manual is to help in solving problems with Pioneer PDP-504CMX. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pioneer PDP-504CMX along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center