Rev. A 1-18-06 1 P/N 620001 Hydrel Fixture Housing - Rust Staining Repair Instructions Before installing this product, read and follow all warning notices and instructions accompanying this product. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage.
P/N 620001 2 Rev. A 1-18-06 SECTION I. FIXTURE HOUSING ENTR Y HUB REP AIR INSTRUCTIONS. STEP 1 Before starting repair , ensure that the inside of the fixture housing has the same style entry hub as shown in Figure 1. It is necessary to verify the correct style entry hub for this warranty repair .
Rev. A 1-18-06 3 P/N 620001 Fixtur e Housing Entry Hub Repair Instructions. STEP 2 1. If there is no internal bond wire as shown, skip to STEP 3. 2 . If there is an internal bond wire or a non-listed potting material around the bond post, remove the potting material completely.
P/N 620001 4 Rev. A 1-18-06 Fixtur e Housing Entry Hub Repair Instructions. STEP 3 If there is no internal bond wire in the conduit, the fixture housing will appear as shown in Figure 3. hn-03-11-16-98 No bond wire in conduit unused bond screw . Figure 3.
Rev. A 1-18-06 5 P/N 620001 Fixtur e Housing Entry Hub Repair Instructions. Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause severe personal injury and/or property damage.
P/N 620001 6 Rev. A 1-18-06 Fixtur e Housing Entry Hub Repair Instructions. STEP 5. 1. Attach an anode block, (with an allen head set screw), installed directly to one of the two unused posts on the hub ring. a. This is done by pushing the center hole of the block firmly and completely over the post, press-fitting it into place.
Rev. A 1-18-06 7 P/N 620001 Fixtur e Housing Entry Hub Repair Instructions. STEP 6. 1. After fully pressing the anode block into place, tighten the set screw with a 3/32 inch allen wrench, see Figure 6. a. The allen wrench is not supplied with the kit.
P/N 620001 8 Rev. A 1-18-06 Fixtur e Housing Entry Hub Repair Instructions. STEP 7 1. If a bonding wire is connected to the bonding lug in the fixture housing cover this connection with a listed potting compound, (Scotchcast 2134 or equivelant). a. This will require the pool water level to be lowered and the potted area dried.
Rev. A 1-18-06 9 P/N 620001 SECTION II. AL TERNA TE REP AIR INSTRUCTIONS, BEFORE 1998. This repair procedure can be used both for small fixture housings and for those with angled conduit hubs. STEP 1. Before starting repair , ensure that the inside of the fixture housing has the same style entry hub as shown in Figure 1.
P/N 620001 1 0 Rev. A 1-18-06 Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause severe personal injury and/or property damage.
Rev. A 1-18-06 1 1 P/N 620001 Alternate Repair Instructions STEP 3 1. Attach No. 8 copper jumper wire to one of the two unused posts on the hub ring. a. Place the ring over the post, and press the jumper wire in the gap between the ring and post opposite the ring set screw.
P/N 620001 1 2 Rev. A 1-18-06 Alternate Repair Instructions STEP 4 1. Attach the anode asssembly to the jumper wire using the mechnical lug. 2. Tighten all the screws firmly. 3. Position the anode to clear the light fixture and the cord, and to be away from the entry hub.
Rev. A 1-18-06 1 3 P/N 620001 Alternate Repair Instructions STEP 5 1. Completely cover the entire entry hub, the bond wire and the post clamp with two parts underwater epoxy putty, (supplied with this kit), to at least 1/4 inch thickness.
P/N 620001 1 4 Rev. A 1-18-06 Alternate Repair Instructions STEP 6 If there is no internal bond wire in the conduit, the unused bond screw and hub can be used to attach the jumper wire. hn-03-11-16-98 No bond wire in conduit unused bond screw Figure 6.
Rev. A 1-18-06 1 5 P/N 620001 Alternate Repair Instructions STEP 7 1. Attach the No. 8 copper jumper wire to the unused bond lug and tighten the screw frimly. 2. Attach the anode assembly to the jumper wire using the mechanical lug. 3. Tighten all the screws firmly.
P/N 620001 1 6 Rev. A 1-18-06 Alternate Repair Instructions STEP 8 1. Completely cover the entire entry hub and the jumper wire connection with two parts of underwater epoxy putty, (supplied with this kit), to at least 1/4 inch thickness.
An important point after buying a device Pentair 620001 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pentair 620001 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pentair 620001 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pentair 620001 you will learn all the available features of the product, as well as information on its operation. The information that you get Pentair 620001 will certainly help you make a decision on the purchase.
If you already are a holder of Pentair 620001, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pentair 620001.
However, one of the most important roles played by the user manual is to help in solving problems with Pentair 620001. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pentair 620001 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center