Instruction/ maintenance manual of the product SD5TAC Pelco
Go to page of 20
SD5T AC Series Spectra Lite™ Dome Systems Operation and Programming Manual C2422M (5/00) ® P elco • 3500 P elco Wa y • Clovis , CA 93612-5699 USA • www .
2 Pelco Manual C2422M (5/00) CONTENTS Section Page IMPORT ANT SAFEGU ARDS AND W ARNINGS ................................................................ 3 OPERA TION .....................................................................................
Pelco Manual C2422M (5/00) 3 IMPOR T ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and ser vicing should only be done by qualified service personnel and conform to all local codes.
4 Pelco Manual C2422M (5/00) OPERA TION POWER-UP DISPLA Y When the Spectra Lite™ dome is pow ered up, the selected protocol, re vision number , and other inf or mation is display ed on the monitor .
Pelco Manual C2422M (5/00) 5 OPERA TING NOTES P AN AND TIL T FUNCTIONS Controller T ype Pan Tilt Fixed speed Speed determined by controller Speed determined by controller Va r iable speed 0.
6 Pelco Manual C2422M (5/00) PROGRAMMING Programming Guide - Spectra Lite 1. Access main menu (preset 95). 2. Make main menu selections . Joystic k: Move up or do wn to position cursor or to toggle between selections. Iris Open: Enter Iris Close: Cancel PRESETS The follo wing presets are reserved for special functions .
Pelco Manual C2422M (5/00) 7 ACCESSING MAIN MENU (PRESET 95) Y ou can call up the main menu on y our monitor by programming (setting or creating) preset 95 (28 if in 32-preset mode). Programming preset 95 f or P elco’ s controllers varies according to the type of controller you are using.
8 Pelco Manual C2422M (5/00) AUTO FLIP There are two auto flip modes: On - Auto flip mode is enab led. Off - A uto flip mode is disabled. To change the auto flip mode: 1. Program preset 95 (28). The main menu appears. 2. P osition the cursor (>) beside Other .
Pelco Manual C2422M (5/00) 9 AUTO IRIS The following are the settings for auto iris: Mode Level To change the settings for auto iris: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Camera. 3. Press the Iris Open button to enter the Camera menu.
10 Pelco Manual C2422M (5/00) Main Menu <Camera> <Line Sync> <Power Up> <Other> EXIT Camera Menu Backlight comp Off Reset camera <Gain/AGC> <Auto-iris> <Next>.
Pelco Manual C2422M (5/00) 11 GAIN The gain adjusts the signal lev el of the video output. Increasing the gain in low light conditions will increase the lev el of noise in the picture. To change the gain: 1. Program preset 95 (28). The main menu appears.
12 Pelco Manual C2422M (5/00) Main Menu <Camera> <Line Sync> <Power Up> <Other> EXIT Line Sync Menu Line sync On Line sync phase 0 Exit Scan Limit Stops Refer to the documentation for your control system for programming presets, and then do the following: 1.
Pelco Manual C2422M (5/00) 13 P ARK TIME MINUTES This feature causes the dome to park at preset 1 after a progr ammed number of minutes of control inactivity . The time can be set from 1 minute to 720 minutes (12 hours), or it can be set to zero, which disables this feature.
14 Pelco Manual C2422M (5/00) RESET CAMERA Main Menu <Camera> <Line Sync> <Power Up> <Other> EXIT Camera Menu Backlight comp Off Reset camera <Gain/AGC> <Auto-iris> <Next> Exit Resetting the camera returns the settings to their defaults.
Pelco Manual C2422M (5/00) 15 SCAN SPEED Next Menu Shutter speed Auto Auto focus mode Auto <Sharpness> <White balance> Prev (bac k to prev .
16 Pelco Manual C2422M (5/00) SHUTTER SPEED Next Menu Shutter speed Auto Auto focus mode Auto <Sharpness> <White balance> Prev (bac k to prev .
Pelco Manual C2422M (5/00) 17 Next Menu Shutter speed Auto Auto focus mode Auto <Sharpness> <White balance> Prev (bac k to prev . menu) Exit Main Menu <Camera> <Line Sync> <.
18 Pelco Manual C2422M (5/00) MAINTENANCE DOME CLEANING Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to scratch the surfaces of the dome. Exterior Surface - Clean the dome’ s exterior surface with a nonabrasiv e cleaning cloth and cleaning agent that is safe f or acrylic.
Pelco Manual C2422M (5/00) 19 SPECIFICA TIONS MECHANICAL Pan Movement: 360 ° continuous pan rotation Ve r tical Tilt: Unobstructed +2 ° to -92 ° Manual P an/Tilt Speeds* Pan: 0.
20 Pelco Manual C2422M (5/00) P elco, the P elco logo, Camclosure, Esprit, Gene x, Legacy , and Spectra are registered trademarks of Pelco . © Cop yright 2000, P elc o. Endura and ExSite are trademarks of P elco. All rights reser ved. U.S . Patent No .
An important point after buying a device Pelco SD5TAC (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco SD5TAC yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco SD5TAC - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco SD5TAC you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco SD5TAC will certainly help you make a decision on the purchase.
If you already are a holder of Pelco SD5TAC, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco SD5TAC.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco SD5TAC. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco SD5TAC along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center