INSTALLATION C3683M (3/09) Network Storage Manager Endura ® NSM5200 Series.
.
C3683M (3/09) 3 Contents Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Video Quality Caution .
4 C3683M (3/09) List of Illustrations 1 Major Package Compon ents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2 Accessory Pack .
C3683M (3/09) 5 Regulatory Notices This device co mplies with Pa rt 15 of the FCC Rules. Operat ion is subject to the following two conditions: (1) this device may n ot c ause harmf ul interference, and (2 ) this device must accept any inte rference received, including interference tha t may cause undesired operat ion.
6 C3683M (3/09) Description The NSM5200 Ser ies networ k storage mana ger (NSM) del ivers indu stry leading p erformanc e and innovati on for miss ion-critica l stor age needs.
C3683M (3/09) 7 the rigors of video record ing applications than an NTFS file syst em, which is st andard with Windows ® -bas ed recorde rs. Altho ugh XFS is superior , fragmentat ion can build up over pr olonged p eriods of ac tive use . T o compe nsate, the s oftware inco rporates defragment ation rout i nes that ru n in the backgroun d.
8 C3683M (3/09) MODELS OPTIONAL ACCESSORIES DAS5200 Series Each DAS5200 Serie s storage expansio n box adds additional st orage to each NSM520 0. Up to seven units can b e connected to an NSM5200 t hrough an external SAS co nnection f or a maximum of 72.
C3683M (3/0 9) 9 Before Y ou Begin Endura is a network system th at requires a continuous amoun t of bandwidth to transmit true , live video; therefore, always inclu de yo ur networ k administrator when planning and installing Endura compon ents.
10 C3683M (3/09) USER -SUPPLIED PARTS In addition to the stan dard tools and cables requ ired for a video security insta llation, you w ill need to provide the following items: Qty Description 1 Cat5e.
Figure 3. Rack Mount Kit Figure 2. Accessory Pack C3683M (3/0 9) 11 A CC E SS ORY P A C K PHILLIP S PA N HEAD SC REW , 8-32 X 0. 375-IN C H 5 EA. (IN S T ALLED) S HOWN A C TUAL S IZE FRONT BEZEL KEY 2 EA. RA C K MOUNT KIT E S D DI S PO S ABLE WRI S T S TRAP 1 EA.
12 C3683M (3/09) PRODUCT SERIAL NUMBER LABEL PLACEMENT Product ser ial number la bels help id entify your system and it s factory conf iguration i n the event that your NSM 5200 or its co mp onents req uire service. Three labels citing your product’ s serial number are attached to t he unit.
C3683M (3/0 9) 13 Equipment Placement and Rack Mounting The NSM5200 can be placed on a flat sur face, such as a deskto p, or mounted in an equip ment rack. DESKTOP INSTALLATION T o install the NSM520 0 on a desktop: 1. Make sure the ru bber feet are installed to prevent surface d amage.
14 C3683M (3/09) RACK MOUNTING The NSM520 0 mounts in to an indust ry-standar d 19-inch (48 cm) equi pment rack. Th e NSM5200 occ upies thr ee rack unit s (5.25 in. or 13.3 cm) of vertical ra ck space. The hardware ne cessary to mount the N SM5200 into a rack is s upplied with the unit.
Figure 7. Assembling a Support Rail C3683M (3/0 9) 15 3. Attach one f ront-mount r ail to one re ar -mount rail. M ake sure the rails are moun ted back to b ack, as shown in Figure 7 . Depending on rack depth, use either three or four 8-32 x 0. 375-inch Philli ps truss head screws fo r each rail set.
16 C3683M (3/09) 6. Attach one supp ort rail assembly to th e equipment rack in th e desired locati on (refer to Figure 9 ): NOTE: Th e support rail a ssemblies ar e identical and may be used on e ither the r ight or left side of the rack. a. Position the ear of the fron t-mount rail against the fr ont of the equipment rack.
Figure 10. Attaching Rack Rail Spacers C3683M (3/0 9) 17 c. T ighten the two screws to secure the spacer to the rack. 9. Repeat step 8 for t he second spacer . 10. T ighten the 8-32 x 0.37 5-inch Philli ps truss head screws that were attached to the front- and rear -m ount rails in steps 3 an d 4.
Figure 12. T ightening the Thumbscrews Figure 13. Installing the Cable Management Bracket 18 C3683M (3/09) 12. After the unit is in place, tighten the two thumbscrews to secure th e unit to the rack. 13. Install t he cable management bracke t on the rear panel as follo ws (refer to Figure 13 ): a.
C3683M (3/0 9) 19 Hard Drive Array Installation The NSM5200 stores data using RA ID (Redundant Array of Independ ent Disks) technology . All NSM5200 Series re corders operate in a RAID 6 configuratio n to maximize fault toleran ce and enha nce disk-a ccess perfor mance.
Figure 15. Installing the Hard Drive Carrier 20 C3683M (3/09) 4. Install each hard dr ive carrier as follows: a. Open the hard drive latch (press down and p ull the spri ng latch). b. With the hard drive latch open, slid e the hard drive carrier gently into an op en hard drive bay (refer to Figure 15 ).
C3683M (3/0 9) 21 Connections Figure 16. Rear Panel Layout Familiarize yourself with the NSM5200 rear panel before connecti ng any equipment to the unit. CONNECTING POWER The NSM5200 is equippe d with two hot-swappab le power supplies. Th ese autoranging power supplies adap t automatically to voltages from 100 to 240 V AC (50/60 Hz).
22 C3683M (3/09) CONNECTING TO THE NETWORK The NSM5200 support s remote administration from an En dura workstation. The N SM5200 is compatible with the entire family of Endu ra-rea dy devices using TCP/IP and UPnP proto cols. Consult your network ad ministrator before in stalling th e NSM5200 t o avoid possible net work c onflicts.
C3683M (3/0 9) 23 Operation Refer to the W eb Browser manual that was shipped with the unit for details on how to access an d configure the NSM5200 . NOTE: T o make sure that all diagnos tic messages will appear to a syst em operator , leave at least one Endura workstation or VCD5000 ru nn ing at all times.
24 C3683M (3/09) s Software Status • Green: The software is operating n ormally . • Amber: A minor software malfun ction is detected (for example, an excessi ve network packet loss). • Red: A fatal softwar e error has o ccurred: fo r example, c easing to r ecord.
C3683M (3/0 9) 25 UNIT STARTUP T o start the unit: 1. Unlock and o pen the front bezel. 2. Press the power button. The power indicator g lows white. Figure 20. Opening the Front Bezel 3. Close and lo ck the front beze l. The Pelco badge now glow s blue.
26 C3683M (3/09) T roubleshooting If the followin g instruct ions fail to solve your problem, contac t Pelco’ s Pro duct Support at 1-800-28 9-9100 (USA a nd Canada) or +1-559-292 -1981 (international) for assistance. Access the prop erties dialog boxes for the NSM 5200 on the Endura wor kstation.
C3683M (3/09) 27 Specifications SYSTEM Operating Syst em Linux RAID Level CompactFlash sy stem drive, RAID 6 for storage drives Effective Capa city Up to 9.082 TB, expandable with DAS5200s Drive Interface SAS/SA TA II User Interface Remote operat ion from Endura wor kstation or VCD5000 Minimum Require ments Microsoft ® Internet Explorer ® 6.
28 C3683M (3/09) PHYSICAL Construction Steel cab inet Finish Front bezel Gray metallic with black end caps Chassis Black matte finish Dimensions 24.3" D x 17.
C3683M (3/0 9) 29 Appendices APPENDIX A: EXPAND ING V IDEO STORAGE Y o u can incre ase the video st orage capac ity of the N SM5200 by ad ding one or more DAS5200 dire ct attached storage (DA S). Each DA S520 0 adds up to 12.0 TB of total capa city (up to 9.
30 C3683M (3/09) APPENDIX B: INSTALLING AN UNIN TERRUPTIBLE POWER SUPPLY (UPS) Y ou should connect each NSM 5200 to a UPS (not supplied). UPS devices maintain a limited amount of backup battery power if the m ain power fails. T o connec t communication a nd power from th e UPS to the NSM5200 (refer to Figure 22 ): 1.
PRODUCT W ARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without c harge, any merchandise proved defective in material or workmanship for a pe riod of one year after the date of shipment.
Pelco, Inc. Worldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el (800) 289-9100 Fax (800) 289-9150 International T el +1 (559) 292-1981 Fax +1 (559) 348-1120 www .
An important point after buying a device Pelco NSM5200 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco NSM5200 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco NSM5200 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco NSM5200 you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco NSM5200 will certainly help you make a decision on the purchase.
If you already are a holder of Pelco NSM5200, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco NSM5200.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco NSM5200. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco NSM5200 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center