EPS5000-120 External Power Supply INSTALLATION C1632M-A (10/06) For Fiber Optic Modules.
.
C1632M-A (10/06) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings.
4 C1632M-A (10/06) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
C1632M-A (10/06) 5 Description The EPS5000-120 external power supply , which is 1 rack unit (RU) high, has dual 120 W power supplies that slide into a tray .
6 C1632M-A (10/06) BACK VIEW Power Switch (2) AC Power Cord Connector (2) 6-Pin Power Connector (2) Relay Output Connector (2) Spare Fuse (2) Figure 2.
C1632M-A (10/06) 7 Installation The following items are supplied with each EPS5000-120. 1 Rack mount chassis 2 Snap-on ferrites 2 Power supplies (EPSPWR-120) 4 Power cords (2 USA standard and 2 European standard) 2 G-power cables (over -molded) 4 Screws, 10-32 x 0.
8 C1632M-A (10/06) Figure 3. Mounting an EPS5000-120 into a Rack Figure 4. Connecting to an RK5000-3U/RK5000PS-3U EPS5000-120 RK5000-3U RK5000PS-3U OVER-MOLDED CABLE OVER-MOLDED CABLE POWER CORD POWER.
C1632M-A (10/06) 9 Service REPLACING A POWER SUPPLY Y ou can easily replace either of the two power supplies in the EPS5000-120 in case of failure. The power fail LED on the front of each power supply turns red if there is a problem with the power supply .
10 C1632M-A (10/06) Specifications ELECTRICAL Input V oltage 100-240 V AC Input Current 3.2 A total Output V oltage 12 VDC per power supply Output Current 10 A per power supply Fuse Rating 1.
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC. This equipment contains electrical or electronic components that mu.
W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
An important point after buying a device Pelco EPS5000-120 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco EPS5000-120 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco EPS5000-120 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco EPS5000-120 you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco EPS5000-120 will certainly help you make a decision on the purchase.
If you already are a holder of Pelco EPS5000-120, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco EPS5000-120.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco EPS5000-120. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco EPS5000-120 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center