DX9000 Series Digital V ideo Recorder C685M-D (2/03) ® INST ALLA TION/OPERA TION DX9000F-C Series & DX9000H-C Series.
2 C685M-D (2/03) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND W ARNINGS .............................................................................................. .................................................................... 3 DESCRIPTION .
C685M-D (2/03) 3 This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and mainte- nance instructions in the literature accompanying this unit.
4 C685M-D (2/03) Figure 1. DX9000 System MODELS DX9008F-C Eight-channel digital video recorder , 30 ips for each camera, Revision C software DX9016F-C Same as DX9008F-C, except has 16 camera inputs DX.
C685M-D (2/03) 5 INST ALLA TION Make sure all of the supplied items are present. 1 Recorder 2 Power cords (1 USA standard and 1 European standard) 1 Patch panel 1-5 BNC mounting plates 1-5 37-pin connectors with 24-inch (61 cm) sets of coaxial cable and BNC connectors 2-10 Screws, 6-32 x .
6 C685M-D (2/03) MOUNTING CAUTION: The recorder should be installed in an air conditioned room where the temperature is maintained between 65° and 70°F (18° and 21°C) with relative humidity not to exceed 80 percent, non-condensing.
C685M-D (2/03) 7 CONNECTIONS Make the following connections on the rear of the recorder . Refer to Figure 3. NOTE: A mouse, keyboard, and monitor are required to configure the recorder to operate over a LAN/W AN network. After configuration, they can be left for network administration and troubleshooting or they can be removed.
8 C685M-D (2/03) Figure 3. DX9000 System Connections COM 2 * STORAGE UNIT #0 ** STORAGE UNIT #2 ** STORAGE UNIT #3 ** STORAGE UNIT #1 ** 37 PIN CONNECTOR PA TCH P ANEL ETHERNET SWITCH RECORDER COM 1 * TO V I EWST A TION * COM 1 AND COM 2 ARE RESERVED FOR PELCO’S USE.
C685M-D (2/03) 9 SYSTEM CONFIGURA TION Necessary Information To configure the recorder , you will need to provide the following information. Most of the information can be obtained from your network administrator . • User name and company name They do not have to be unique.
10 C685M-D (2/03) Figure 4. Server Configuration 1. Windows should boot up all the way to the desktop without user intervention. Close all recording applications on the desktop. On the task bar click Start > Programs > DX9000 Server > Server Configuration Utility .
C685M-D (2/03) 11 8. Define the Pre-Alarm Interval for the cameras associated with this recorder . These values are listed in seconds. The default is 60 seconds. This feature is relevant only if you do not intend to record continuously (24 hours a day) and wish to record events only during part or all of the day .
12 C685M-D (2/03) 1. Double-click the Client Configuration Utility icon if it's on the viewstation desktop or click the Start button and go to Programs > Viewstation > Client Configuration Utility . 2. Enter user name and password. The default is admin/admin.
C685M-D (2/03) 13 NETWORK CONNECTION The following is required: • Dedicated LAN of four or more ViewStations requires a minimum network of 100BaseT (100 Mbit/sec) • Integration within an existing LAN/W AN requires a network of 100BaseT (100 Mbit/sec) 1.
14 C685M-D (2/03) SPECIFICA TIONS ELECTRICAL/VIDEO Input V oltage: 100-240 V AC, 50/60 Hz, auto-ranging Power Consumption: 195W maximum Signal System: NTSC/P AL Operating System: Windows 2000 and SP1 Service Pack Recording Resolution NTSC: 352 x 240 pixels P AL: 384 x 288 pixels Compression: MPEG Compressed Image Size: 352 x 240: average 1.
C685M-D (2/03) 15 REVISION HISTORY Manual # Date Comments C685M 5/01 Original version. C685M-A 7/01 Revised the Installation and Specifications sections. C685M-B 6/02 Revised format. Updated for V ersion C software. C685M-C 9/02 Updated parts list on page 7.
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
An important point after buying a device Pelco DX9000H-C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco DX9000H-C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco DX9000H-C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco DX9000H-C you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco DX9000H-C will certainly help you make a decision on the purchase.
If you already are a holder of Pelco DX9000H-C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco DX9000H-C.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco DX9000H-C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco DX9000H-C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center