Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108 Inte.
2 Pelco Manual C1498M-B (7/99) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND W ARNINGS ................................................................ 3 DESCRIPTION ...................................................................................
Pelco Manual C1498M-B (7/99) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS Observe the f ollowing warnings before installing and using this product. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
4 Pelco Manual C1498M-B (7/99) 2. Set the s witches on the bottom of the dome drive. Ref er to T able A f or the settings for SW1, and T able B and T able C for SW2. 3. Install the dome drive in the bac k box. Line up the green tab and red tab on the dome drive with the green label and red label on the bac k bo x.
Pelco Manual C1498M-B (7/99) 5 Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF.
6 Pelco Manual C1498M-B (7/99) Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 57 ON OFF OFF ON ON ON OFF OFF 58 OFF ON OFF ON ON ON OFF OFF 59 ON ON OFF ON ON ON OFF O.
Pelco Manual C1498M-B (7/99) 7 1 1 3 ON OFF OFF OFF ON ON ON OFF 1 1 4 OFF ON OFF OFF ON ON ON OFF 1 1 5 ON ON OFF OFF ON ON ON OFF 1 1 6 OFF OFF ON OFF ON ON ON OFF 1 1 7 ON OFF ON OFF ON ON ON OFF 1.
8 Pelco Manual C1498M-B (7/99) 169 ON OFF OFF ON OFF ON OFF ON 170 OFF ON OFF ON OFF ON OFF ON 171 ON ON OFF ON OFF ON OFF ON 172 OFF OFF ON ON OFF ON OFF ON 173 ON OFF ON ON OFF ON OFF ON 174 OFF ON .
Pelco Manual C1498M-B (7/99) 9 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF OFF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON .
10 Pelco Manual C1498M-B (7/99) P AN AND TIL T FUNCTIONS Use your controller’ s joystic k to control pan and tilt operation. • Fixed-Speed Controllers – P an and tilt operation is at a fix ed speed; the controller determines the speed.
Pelco Manual C1498M-B (7/99) 11 Software controls scan limit stops . When the dome reaches one , it immediately re verses direction. Refer to the Limit Stops section to program the scan limit stops . Program preset 96 (29) to stop a scan. Any pan and tilt or lens command also stops a scan.
12 Pelco Manual C1498M-B (7/99) CM9750 1. T ur n the KEY SWITCH to the ON position. 2. Press the PROG k ey . PROGRAM appears on the LCD screen. 3. Press the PRES ke y . The PRESET prompt appears. 4. Enter 95 and press the ENTER ke y . The main menu appears .
Pelco Manual C1498M-B (7/99) 13 GAIN/AGC AGC Mode The two AGC (A utomatic Gain Control) modes are auto and off. • In auto mode, the dome automatically adjusts the gain–the amount of amplification the camera places on its video inf ormation to obtain a full 1-volt peak-to-peak video signal out.
14 Pelco Manual C1498M-B (7/99) 6. Mov e the jo ystick up or do wn to position the cursor beside one of the choices. Press the Iris Open button. MODE – The cursor mov es to one of two choices: A uto or Off. In the Auto mode , the iris is automatically adjusted to produce a constant video output as determined by the Level setting below .
Pelco Manual C1498M-B (7/99) 15 T o change the mode: 1. On the main menu, mov e the joystick up or do wn to position the cursor (>) beside Camera. 2. Press the Iris Open button to enter the Camera submenu. 3. Mov e the jo ystick up or do wn to position the cursor beside Ne xt.
16 Pelco Manual C1498M-B (7/99) T o change the line synchronization settings: 1. On the main menu, mov e the joystick up or do wn to position the cursor (>) beside Line Sync. 2. Press the Iris Open button. Another menu appears with the Line Sync and Line Sync Phase selections.
Pelco Manual C1498M-B (7/99) 17 LIMIT STOPS The two types of limit stop are manual and scan. When manual limit stops are set, a manual (joystic k) pan operation stops when a limit is reached. When scan limit stops are set, the dome rev erses direction during random, frame, and auto scanning when a limit stop is reached.
18 Pelco Manual C1498M-B (7/99) 3. Mov e the jo ystick up or do wn to position the cursor beside Scan Speed deg/s. 4. Press the Iris Open button. The cursor mov es to the right beside the current number of degrees. 5. Move the joystick up or down to toggle through the number of degrees (1-40) until you reach the number you w ant.
Pelco Manual C1498M-B (7/99) 19 8. If the red power LED is lit, turn off power . a. Open the door to the interconnect circuit board and check that all connectors are fully seated. b. Make sure the wiring is correct between the unit and controller . c.
20 Pelco Manual C1498M-B (7/99) REVISION HISTOR Y Manual # Date Comments C1498M 2/99 Original v ersion. 3/99 Remo ved reference to line synchronization. Added material on auto iris. Added FCC notice. C1498M-A 7/99 Revised the preset tilt speed from 100 to 200 deg rees/second.
An important point after buying a device Pelco DD5TA Series (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco DD5TA Series yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco DD5TA Series - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco DD5TA Series you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco DD5TA Series will certainly help you make a decision on the purchase.
If you already are a holder of Pelco DD5TA Series, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco DD5TA Series.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco DD5TA Series. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco DD5TA Series along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center