INST ALLA TION ICS150-CW Series Camclosure ® Integrated Camera System Wide Dynamic Range (WDR) C3407M-D (1/07).
.
C3407M-D (1/07) 3 Contents Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 C3407M-D (1/07) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
C3407M-D (1/07) 5 Description The ICS150-CW Series Camclosure ® integrated camera system combines an environmental cover, back box, camera, lens, and lower dome into a small, high-security system that is quick and easy to install.
6 C3407M-D (1/07) Figure 1. Package Components BACK BOX (1) CAMERA MODULE (1) TRIM RING, DOME LINER, AND CLEAR BUBBLE (1) TRIM RING AND SMOKED BUBBLE (1) < OR > 1/8-INCH HOLLOW SCREWDRIVER BIT (1) ADAPTER PLA TE (1) SHOWN ACTUAL SIZE SHIPPING BOX 8-32 X 1.
C3407M-D (1/07) 7 Cover and Back Box Installation The ICS150-CW Series Camclosure integrated camera system mounts only into a wall or ceiling. UNSHIELDED T WISTED PAIR (UTP) V IDEO The ICS150-CW Series offers support for unshielded twisted pair (UTP).
8 C3407M-D (1/07) SUSPENDED CEILING NOTE: Y ou should install the camera module into the back box before installing the back box into the surface. When installing the back box into the surface, rotate the camera module to access the mounting holes. Refer to Camera Module on page 10 for more information.
C3407M-D (1/07) 9 4S DEEP ELECTRICAL BOX NOTE: Y ou should install the camera module into the back box before installing the back box into the surface. When installing the back box into the surface, rotate the camera module to access the mounting holes.
10 C3407M-D (1/07) Camera Module The ICS150-CW Series Camclosure camera module includes the camera, camera bracket, and heater board. T o perform most camera adjustments, you must remove the module from the back box. Use the following instructions to remove and reinstall the camera module.
C3407M-D (1/07) 11 2. Unplug the camera (10-pin), heater board (four-pin), and service (three-pin) connectors from the back box (refer to Figure 6). Figure 6.
12 C3407M-D (1/07) CAMERA ORIENTATION At the factory , the camera module is confi gured for ceiling mounting. For wall mounting, you must change the camera orientation or the video image will be upside down. T o change the camera orientation (refer to Figure 7): 1.
C3407M-D (1/07) 13 Camera Adjustments T o perform the following camera adjustments, make sure to plug in the camera and service connectors. Y ou may have to remove the camera module from the back box. Connect a monitor . Then turn on power to the camera and monitor.
14 C3407M-D (1/07) SWITCH SETTINGS Locate the DIP switch (refer to Figure 9). Then set the switches for your installation. Figure 9. DIP Switch SW1: Video Format Set to ON for NTSC. Set to OFF for PAL. The default is ON. SW2: Line Sync Set to ON to use AC line lock.
C3407M-D (1/07) 15 Extended dynamic range: Use for extremely high dynamic installations, for example, doorways, entrances, and exits. This profi le offers the maximum wide dynamic range. Fluorescent: Use for any installation with fl ickering lighting of any kind.
16 C3407M-D (1/07) Camera Positioning Manually rotate and tilt the camera module to position the camera. Then tighten the tilt screws (axis in Figure 11). NOTE: Do not over-rotate the module. Excessively turning the module in one direction could result in damage to the wiring.
C3407M-D (1/07) 17 Install Dome and T rim Ring 1. Adjust the dome liner if installed (refer to Figure 12): a. Align the screw holes in the trim ring with those in the back box to identify the proper dome liner position. b. Loosen the three Phillips screws located in the trim ring.
18 C3407M-D (1/07) Service Connector The ICS150-CW Series Camclosure integrated camera system includes a service connector that outputs camera video. Use it at the installation site to set up the fi eld of view and focus the camera. Figure 13. Service Connector Pelco offers two optional items that plug directly into the service connector .
C3407M-D (1/07) 19 T o assemble a longer service cable for the Camclosure integrated camera system, purchase the following from a local electronics supply store: 1 2.5 mm monaural headphone plug 1 CPM 88 miniature coaxial connector 1 RG174/U coaxial cable T o assemble the cable: 1.
20 C3407M-D (1/07) Specifications CAMERA Imaging Device 1/3-inch imager Dynamic Range 102 dB typical/120 dB maximum Picture Elements Sensor resolution: 742 (H) x 552 (V) Signal System NTSC or PAL Sca.
C3407M-D (1/07) 21 BACKBOX Electrical Input Voltage** 12 VDC or 24 VAC (±10%), autosensing Power Consumption 10 watts or less Video Connector Composite: BNC UTP: T wisted pair General Pan/T ilt Adjus.
22 C3407M-D (1/07).
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repa ir or replace, without charge, any merc ha ndise proved defective in material or wo rkmanship for a period of one year after the date of shipment.
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.
An important point after buying a device Pelco C3407M-D (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco C3407M-D yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco C3407M-D - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco C3407M-D you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco C3407M-D will certainly help you make a decision on the purchase.
If you already are a holder of Pelco C3407M-D, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco C3407M-D.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco C3407M-D. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco C3407M-D along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center