Instruction/ maintenance manual of the product C2423M (5/00) Pelco
Go to page of 28
SD5BCBW Series Spectra II™ Color/Black & White Dome Systems Operation and Programming Manual C2423M (5/00) ® P elco • 3500 P elco Wa y • Clovis , CA 93612-5699 USA • www .
2 Pelco Manual C2423M (5/00) CONTENTS Section Page IMPORT ANT SAFEGU ARDS AND W ARNINGS ................................................................ 3 OPERA TION .....................................................................................
Pelco Manual C2423M (5/00) 3 IMPOR T ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser v ed. 1. Installation and ser vicing should only be done by qualified service personnel and conform to all local codes.
4 Pelco Manual C2423M (5/00) OPERA TION POWER-UP DISPLA Y When the Spectra II™ dome is pow ered up, the selected protocol, re vision number , and other inf or mation is display ed on the monitor .
Pelco Manual C2423M (5/00) 5 OPERA TING NOTES P AN AND TIL T FUNCTIONS Controller T ype Pan Tilt Fixed speed Speed determined by controller Speed determined by controller Va r iable speed 0.
6 Pelco Manual C2423M (5/00) PA TTERNS The Spectra II dome can do either one full pattern (1.5, 3, or 6 minutes long) or two half patterns (.75, 1.5, or 3 minutes long). This patter n can consist of any standard pan and tilt or lens command. Presets, flip, and turbo are not allowed in a pattern.
Pelco Manual C2423M (5/00) 7 AUXILIAR Y OUTPUTS An A UX 1 command from the controller will activate the rela y in the dome and operate the de vice that is connected to the relay .
8 Pelco Manual C2423M (5/00) PROGRAMMING Programming Guide - Spectra II Color/Black & White 1. Access main menu (preset 95). 2. Make main menu selections . Joystic k: Move up or do wn to position cursor or to toggle between selections. Iris Open: Enter Iris Close: Cancel PRESETS The follo wing presets are reserved for special functions .
Pelco Manual C2423M (5/00) 9 ACCESSING MAIN MENU (PRESET 95) Y ou can call up the main menu on your monitor b y programming (setting or creating) preset 95 (28 if in 32-preset mode). Programming preset 95 f or P elco’ s controllers varies according to the type of controller you are using.
10 Pelco Manual C2423M (5/00) ALARMS The Spectra II dome has se ven alarm inputs, which can be designated as either high or low prior ity . The high prior ity setting is significant when more than one alarm is activated. If priority in alarms is not required, leave all alarms in the low setting.
Pelco Manual C2423M (5/00) 11 6. P osition the cursor (>) beside the number of the alarm input for which you w ant to set the pattern. 7. Press the Iris Open button. The cursor mov es to the right, beside the words Full Pat, Half P at 1, Half Pat 2, or No P attern.
12 Pelco Manual C2423M (5/00) AUTO FLIP There are two auto flip modes: On - Auto flip mode is enab led. Off - A uto flip mode is disabled. To change the auto flip mode: 1. Program preset 95 (28). The main menu appears . 2. P osition the cursor (>) beside Other .
Pelco Manual C2423M (5/00) 13 AUTO IRIS The following are the settings for auto iris: Mode Level To change the settings for auto iris: 1. Program preset 95 (28). The main menu appears . 2. Position the cursor (>) beside Camera. 3. Press the Iris Open button to enter the Camera menu.
14 Pelco Manual C2423M (5/00) AUTO IR LEVEL The IR lev el setting determines when the IR filter will switch IN or OUT . F ollowing are the av ailable settings f or the Auto IR Le vel: Dusk = 1/60 seco.
Pelco Manual C2423M (5/00) 15 There are two backlight compensation modes: On - The dome uses the center 10 percent of the picture to adjust the iris. If there is a bright light source outside of this area, it will wash out to white. The camera will adjust the iris so that the object in the sensitive area is properly exposed.
16 Pelco Manual C2423M (5/00) Main Menu <Camera> <Line Sync> <Power Up> <Aux> <Alarms, Zone Blank> <Other> EXIT Camera Menu Backlight comp Off Zoom limit x72 Reset .
Pelco Manual C2423M (5/00) 17 Next Menu Slow shutter mode Auto Shutter speed Auto Auto focus mode Auto <IR Filter> <Sharpness> <White balance> Previous Exit Main Menu <Camera> .
18 Pelco Manual C2423M (5/00) NOTE: Programming preset 90 (23) disables the manual limit stops until preset 91 (24) is set. TURNING LIMIT STOPS ON OR OFF To change the limit stop mode: 1. Program preset 95 (28). The main menu appears . 2. P osition the cursor (>) beside Other .
Pelco Manual C2423M (5/00) 19 LINE SYNC PHASE - The cursor mov es to a numeric value. Mo ve the joystic k up or down to change the value . Press the Ir is Open b utton to select the choice. The value represents the phase angle in tenths of a degree between 0 degrees and 359 degrees.
20 Pelco Manual C2423M (5/00) Main Menu <Camera> <Line Sync> <Power Up> <Aux> <Alarms, Zone Blank> <Other> EXIT Other Menu A uto flip On Proportional pan On Limit stops Off Park time minutes 0 Scan speed deg/s 25 Pattern length 1.
Pelco Manual C2423M (5/00) 21 3. Press the Iris Open button to enter the Other menu. 4. Position the cursor (>) beside Proportional Pan. 5. Press the Iris Open button. The cursor mov es to the right, beside the word On or Off. 6. Mov e the joystick up or do wn to toggle between On and Off.
22 Pelco Manual C2423M (5/00) SCAN SPEED Next Menu Slow shutter mode Auto Shutter speed Auto Auto focus mode Auto <IR Filter> <Sharpness> <White balance> Previous Exit Main Menu <.
Pelco Manual C2423M (5/00) 23 SHUTTER SPEED Next Menu Slow shutter mode Aut o Shutter speed Auto Auto focus mode Auto <IR Filter> <Sharpness> <White balance> Previous Exit Main Menu .
24 Pelco Manual C2423M (5/00) SLOW SHUTTER MODE Next Menu Slow shutter mode Aut o Shutter speed Auto Auto focus mode Auto <IR Filter> <Sharpness> <White balance>* Previous Exit Main .
Pelco Manual C2423M (5/00) 25 WHITE BALANCE Next Menu Slow shutter mode Auto Shutter speed Auto Auto focus mode Auto <IR Filter> <Sharpness> <White balance> Previous Exit Main Menu &.
26 Pelco Manual C2423M (5/00) NOTE: The Spectra II Color/Black and White camera cannot do electronic zoom in a pattern. Optical zoom will operate in a pattern.
Pelco Manual C2423M (5/00) 27 SPECIFICA TIONS MECHANICAL Pan Movement: 360 ° continuous pan rotation Ve r tical Tilt: Unobstructed +2 ° to -92 ° Manual P an/Tilt Speeds* Pan: 0.
28 Pelco Manual C2423M (5/00) P elco, the P elco logo , Camclosure, Esprit, Genex, Legacy , and Spectra are registered trademarks of Pelco . © Cop yright 2000, P elc o. Endura and ExSite are trademarks of P elco. All rights reser ved. U .S. P atent No.
An important point after buying a device Pelco C2423M (5/00) (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco C2423M (5/00) yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco C2423M (5/00) - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco C2423M (5/00) you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco C2423M (5/00) will certainly help you make a decision on the purchase.
If you already are a holder of Pelco C2423M (5/00), but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco C2423M (5/00).
However, one of the most important roles played by the user manual is to help in solving problems with Pelco C2423M (5/00). Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco C2423M (5/00) along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center