Frequency Response, 1 Meter On-axis, Swept-sine in Anechoic Environment: 63 Hz - 18.5 kHz (±3 dB) Usable Low Frequency Limit (-10 dB point): 48 Hz Power Handling: Full Range: 750 W continuous 1,500 W.
3rd Harmonic: 100 Hz: 0.62% 1 kHz: 0.25% 10% rated power 2nd Harmonic: 100 Hz: 5.49% 1 kHz: 0.75% 3rd Harmonic: 100 Hz: 2.44% 1 kHz: 0.30% Crossover Frequency (internal passive): Low Frequency - High Frequency: 1,600 Hz Time Offset: Low Frequency: 0.00 ms High Frequency: 0.
3 Features • 63 Hz to 18.5 kHz bandpass • 4" diaphragm, 1.6" exit, Ferrofluid equipped high frequency compression driver • Patented Quadratic Throat Waveguide ™ • Carefully tailore.
array [see limitations under mounting instructions]. Both versions of the ILS 1294 are solidly constructed of 3/4" void free poplar plywood and finished with an exterior grade hardened black paint. Frequency Response This measurement is useful in determining how accurately a given unit reproduces an input signal.
-90 o -60 o -30 o 0 o 30 o 60 o 90 o 200 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 315 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 500 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 800 Hz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.25 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 1.
-90 o -60 o -30 o 0 o 30 o 60 o 90 o 3.15 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 8 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 12.5 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 16 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 4 kHz -90 o -60 o -30 o 0 o 30 o 60 o 90 o 6.
0 o 30 o 60 o 90 o -30 o -60 o -90 o 200 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 315 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 500 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 800 Hz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1.25 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 1.
0 o 30 o 60 o 90 o -30 o -60 o -90 o 3.15 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 8 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 12.5 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 16 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 4 kHz 0 o 30 o 60 o 90 o -30 o -60 o -90 o 6.
9 A A View A-A 10.723 10.955 2.220 8.704 17.712 2.220 22.500 2.220 8.283 19.356 26.940 2.220 9.017 ILS 1294V.
10 ILS 1 294V A PRODUCT OF PEAVEY ELECTRONICS CORP. TM FULL RANGE 1+ & 2+ (+) 1- & 2- (-) BIAMP 1+: LF+ 1-: LF- 2+: HF+ 2-: HF- WARNING: CONSUL T SPEC SHEET FOR FULL SUSPENSION RA TINGS. DO NOT EXCEED 400 lbs. OR 45 DEGREE ANGLE 6,059,069 AND 6,064,745 FULL R ANGE BIAMP 750W RMS CONT.
11 NOTES:.
Features and specifications subject to change without notice. Peavey Electronics Corporation • 71 1 A Street • Meridian • MS • 39301 (601) 483-5376 • F AX (601) 486-1678 • http://aa.
An important point after buying a device Peavey ILS 1294V (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Peavey ILS 1294V yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Peavey ILS 1294V - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Peavey ILS 1294V you will learn all the available features of the product, as well as information on its operation. The information that you get Peavey ILS 1294V will certainly help you make a decision on the purchase.
If you already are a holder of Peavey ILS 1294V, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Peavey ILS 1294V.
However, one of the most important roles played by the user manual is to help in solving problems with Peavey ILS 1294V. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Peavey ILS 1294V along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center