Instruction/ maintenance manual of the product 2500 Series Patton electronic
Go to page of 20
USER MANUAL MODEL 2500 Series Models 2500, 2510, 2520 All-Rate CSU/DSU SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 P ar t# 07M2500-C Doc# 099021UC Revised 3/13/96.
T ABLE OF CONTENTS Section P age 1.0 General Inf ormation ...............................................................2 1.1 W arr anty Statement 1.2 Radio and TV Interf erence 1.3 FCC Inf or mation 1.4 Ser vice Inf or mation 2.0 Product Ov er vie w .
2.0 PRODUCT OVERVIEW This section provides an o v er view of the Model 2500 Series, including f eatures , general description, and a breakdown of model numbers b y application.
3.0 INST ALLA TION This section descr ibes connection of the Model 2500 Ser ies to the DTE and telco (line) interf aces , as well as AC pow er connection 3.1 DTE INTERF A CE CONNECTION The Model 2500 Ser ies has connectors f or both V .35 and RS-232 interf aces .
4.0 CONFIGURA TION Bef ore y ou can operate your Model 2500 Series CSU/DSU , you must configure the unit. Configur ation ma y be done using the e xter nally accessib le hardware s witches or b y using the software s witches .
4.1.1 SWITCH SET SW1 The configuration s witches on s witch set SW1 allo w you to specify Line Rate , Circuit Assurance , R TS, Char acter Length, Data Format and DSR Loop Status. Figure 3 (belo w) summar iz es SW1 s witch settings , including the f actor y def aults.
Character Length In asynchronous data f or mat, 10 and 11 bit characters are suppor ted. This setting is ignored in synchronous data format. Character Char acter Descr iption SW1-6 Length Start Data b.
DTE Loop Contr ol The local loop and remote loop can be activ ated from the DTE interf ace using signals “LL ” and “RL ”. SW2-4 On Enab le LL and RL inputs Off Disab le Cloc k Mode The appropriate transmitter cloc king modes can be selected f or Dedicated DDS , Switched-56 or campus-area (pr iv ate) operation.
4.2.1 USING THE SOFTW ARE MENU SYSTEM The Model 2500 Ser ies Men u System operates as f ollo ws: 1) All selections must be follo wed by [RETURN]. 2) T o mak e a selection from an y menu, enter the option number at the prompt and press [RETURN]. 3) T o e xit an y menu without making a selection, press [ESC] f ollo wed by [RETURN].
Character Length Choosing option 4 in the Softw are Switch Men u takes you to the Character Length Men u (below). In asynchronous data f or mat, the Model 2500 Ser ies suppor ts 10-bit and 11-bit character lengths . Set this option according to the characteristics of the data being transmitted.
Note 2 : Y ou can use the Model 2500 Ser ies to transmit low er-speed asynchronous data (up to 9.6 kbps) ov er synchronous circuits b y simple o ver-sampling. T o do this, select the synchronous data f or mat and set the line Line Rate (Softw are Switch Men u option 1) to at least f our times that asynchronous data rate y ou wish to send.
21 22 Cloc k Mode Choosing option 9 in the Software Switch Men u takes y ou to the Cloc k Mode Menu (belo w). Set this option as f ollo ws: • Internal (Master): T o use the Model 2500 Ser ies inter nal reference cloc k as the timing source, select item 1.
5.0 OPERA TION Once the Model 2500 Ser ies unit is installed and configured proper ly it is ready to oper ate. This section describes the function of the LED indicators, the status displa ys, the use of loopbac k test modes, and Switched 56 dialing procedures (Models 2510 and 2520 only).
25 26 In the Read Configuration Men u, you ma y select item 1 to read the hardw are s witch configuration or item 2 to read the software s witch configuration. A sample screens is sho wn below: 5.2.2 DISPLA YING LINE/LOOP ST A TUS T o chec k the current status of the Model 2500 Ser ies and the associated circuit, go to the Main Menu (see Section 4.
27 28 LAL T est Pr ocedure Once LAL is activ ated, the Model 2500 Ser ies tr ansmit output is connected to its own receiv er . The “T est” LED should be lit. F ollo w these steps to complete the test: 1) V erify that the data ter minal equipment is operating properly and can be used f or a test.
29 30 CSU Loop The CSU Loop is activ ated when the central office re v erses the DC sealing current that flows betw een the TX pair and the RX pair . In this case , the Model 2500 Ser ies recognizes this and loops signals on the RX pair bac k to the central office on the TX pair (see Figure 8, below).
31 32 5.5 SWITCHED 56 DIALING COMMANDS (MODELS 2510 & 2520) T o access the Switched 56 dialing capabilities of the Mode 2500 Ser ies , go to the Main Menu (see Section 4.2 ) and select item 5, “Set Switched 56 Dialing P ar ameters”. This will take y ou to the Switched 56 Menu (see belo w).
33 34 APPENDIX A SPECIFICA TIONS DDS T ype: Dedicated T ransmission Format: Asynchronous, synchronous Interface: RS-232 and V .35 Standar ds: A T&T 62310 compliant DDS Line Rates: 2.4, 4.8, 9.6, 19.2, 56 and 64 kbps DTE Rates: 2.4, 4.8, 9.6, 19.2, 38.
35 36 APPENDIX C F A CT OR Y REPLACEMENT P ARTS AND A CCESSORIES P atton Model # Description 10-2500 ...........................DDS Cab le, RJ48 - RJ48, 6 f oot 10-561S ...........................Control P or t Cable, EIA-561, 6ft, shielded 12M-561 ..
(APPENDIX D - Continued) DB-25 CONNECT OR, TERMINAL INTERF A CE Pin # Signal 1 F rame Ground 2 TD 3 RD 4 R TS 5 CTS 6 DSR 7 SGND (Signal Ground) 8 CD 15 TC 17 RC 18 LL (Local Loop) 20 DTR 21 RL (Remote Loop) 24 XTC 25 TM (T est Mode) CONTR OL PORT INTERF A CE 8 P osition modular connector compliant with EIA-561.
An important point after buying a device Patton electronic 2500 Series (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Patton electronic 2500 Series yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Patton electronic 2500 Series - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Patton electronic 2500 Series you will learn all the available features of the product, as well as information on its operation. The information that you get Patton electronic 2500 Series will certainly help you make a decision on the purchase.
If you already are a holder of Patton electronic 2500 Series, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Patton electronic 2500 Series.
However, one of the most important roles played by the user manual is to help in solving problems with Patton electronic 2500 Series. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Patton electronic 2500 Series along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center